background image

3

W415-0369 / F / 12.10.07

NAPOLEON® gas appliances are manufactured under the strict Standard of the world recognized 

ISO 9001 : 2000 Quality Assurance Certifi cate.

NAPOLEON® products are designed with superior components and materials, assembled by trained 
craftsmen who take great pride in their work. Th

  e burner and valve assembly are leak and test-fi red at a 

quality test station. Once assembled the complete appliance is thoroughly inspected by a qualifi ed technician 
before packaging to ensure that you, the customer, receives the quality product that you expect from 
NAPOLEON®.

NAPOLEON® warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears 
on the warranty registration card 

 led with NAPOLEON® -- provided that the purchase was made through an authorized NAPOLEON® dealer and is subject to the following

conditions and limitations:

This limited warranty applies only while the unit remains at the site of original installation, and only if the unit is installed in Canada or the United States.

This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.

Installation must be done in accordance with the installation instructions included with the product and all local and national building and 

 re codes.

This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will 
nullify this warranty.

This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners, mechanical breakage 
of  logs and embers.

In the 

 rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been 

operated in accordance with the operation instructions and under normal conditions.

After the 

 rst year, with respect to this Limited Warranty, NAPOLEON® may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original 

warranted purchaser the wholesale price of any warranted but defective part(s).

After the 

 rst year, NAPOLEON® will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses 

are not covered by this warranty.

Notwithstanding any provisions contained in this Limited Warranty, NAPOLEON’S responsibility under this warranty is de

 ned as above and it shall not in any event extend to 

any incidental, consequential or indirect damages.

This warranty de

 nes the obligations and liability of NAPOLEON® with respect to the NAPOLEON® gas appliance and any other warranties expressed or implied with respect 

to this product, its components or accessories are excluded.

This limited warranty does not cover damages resulting from the use of components not supplied with the appliance, or the use of fuel other than those speci

 ed.

Any damages to appliance due to weather, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON®.

The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration 
card must be returned within fourteen days to register the warranty.

NAPOLEON® reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.

CONDITIONS AND LIMITATIONS

All stainless steel components of your new NAPOLEON® gas appliance are warranted against defects for 
fi ve years.

All parts such as gas valves, logs, gasketing are covered and NAPOLEON® will provide replacement parts 
free of charge during the fi rst year of the limited warranty.

Labour related to warranty repair is covered free of charge during the fi rst year. Repair work, however, 
requires the prior approval of an authorized company offi

  cial. Labour costs to the account of NAPOLEON® 

are based on a predetermined rate schedule and any repair work must be done through an authorized 
NAPOLEON® dealer.

NAPOLEON® GAS APPLIANCE 5 YEAR LIMITED WARRANTY

Summary of Contents for GSS36N

Page 1: ...result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other ammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF...

Page 2: ...away to avoid burns or clothing ignition Keep young children and animals away when the replace is hot Clothing or other ammable material should not be placed on or near the replace Any safety screen o...

Page 3: ...this Limited Warranty NAPOLEON may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted...

Page 4: ...st pressures in excess of 1 2 psig 3 5 kPa The replace must be isolated from the gas supply piping system by clos ing its individual manual shutoff valve during any pressure testing of the gas supply...

Page 5: ...oved Assure that a continuous gas ow is at the burner before re installing the door GAS INSTALLATION If installing a propane replace the propane cylinder must always be on the exterior of such a struc...

Page 6: ...e the clearance needed Combustible materials may be installed ush with the front of the replace but must not cover any of the outer frame face areas of the replace Non combustible material brick stone...

Page 7: ...og 4 against the left rebox side and pulled forward to the grate The top of the log should rest in the pocket on the back log 4 Position the notch located on the end of the center log 5 against the mi...

Page 8: ...rushing at least once a year 2 Check to see that all burner ports are burning Clean out any of the ports which may not be burning or are not burning properly 3 Check to see that the pilot ame is large...

Page 9: ...OT INJECTOR 5 W455 0067 PROPANE GAS PILOT INJECTOR 6 W725 0028 NATURAL GAS VALVE 6 W725 0029 PROPANE GAS VALVE 7 W385 0334 NAPOLEON LOGO 8 GL 639OD LOG SET 9 W135 0183OD BACK LOG 1 10 W135 0184OD LEFT...

Page 10: ...faulty loosen and tighten thermocouple clean thermocouple and valve connection replace thermocouple replace valve Faulty valve replace Pilot burning no gas to main burner gas knob is on HI wall switch...

Page 11: ...ground or replace wire Remote wall switch wire is grounding Carbon is being deposited on logs or combustion chamber surfaces Flame is impinging on the logs or combustion chamber check that the logs ar...

Page 12: ...12 W415 0369 F 12 10 07 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Reviews: