2.4  RATING PLATE INFORMATION

For rating plate location, see "INSTALLATION OVERVIEW" section

This illustration is for reference only.  Refer to the rating plate on the appliance for accurate information.

NOTE: This rating plate must remain with the appliance at all times. It must not be removed.

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the 

appliance and must be installed.

W415-1427 / 12.23.14

8  

EN

2.4  RATING PLATE INFORMATION

W385-1999

GDS50

GDS50-N

NATURAL GAS MODEL

CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.

DIRECT VENT GAS FIREPLACE APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM 
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE 
CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED 
STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. 
WHEN THIS US  STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR 
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. 

FOR USE ONLY WITH 

BARRIER W565-0196. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.

FOYER À GAZ VENTILÉS À ÉVACUATION DIRECTE. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, 

UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION 

CONFORME AUX EXIGENCES DE LA NORME CAN/CSA  Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN 

VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS

 MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE 

APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR 

LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. 

POUR

UNE UTILISER SEULMENT AVEC BARRIÈRE W565-0196. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE TROUVENT

 DANS LE MANUEL D'INSTALLATION.

MANIFOLD PRESSURE: 

3.5 INCHES W.C. (NG) 

PRESSION AU COLLECTEUR:

 3.5" D'UNE 

COLONNE D'EAU(GN)

MIN SUPPLY PRESSURE:

  4.5" W.C.(NG)

PRESSION D'ALIMENTATION MIN: 

4.5" D'UNE 

COLONNE D'EAU (GN)

MAX. SUPPLY PRESSURE:

 7" W.C. (NG)

PRESSION D'ALIMENTATION MAX:

 7" D'UNE 

COLONNE D'EAU (GN)

MANIFOLD PRESSURE:

 10 INCHES W.C.(LP)

PRESSION AU COLLECTEUR: 

10" D'UNE 

COLONNE D'EAU (P)

MIN SUPPLY PRESSURE:

  11" W.C. (LP)

PRESSION D'ALIMENTATION MIN:

 11" D'UNE 

COLONNE D'EAU (P)

MAX. SUPPLY PRESSURE:

 13" W.C. (LP)

PRESSION D'ALIMENTATION MAX:

 13" D'UNE 

COLONNE D'EAU (P)

SERIAL NUMBER / NO. DESERIE

CDVS500-N

GDS50-P

CDVS50-P

PROPANE MODEL

WOLF STEEL LTD.

24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA

 

9700539 (WSL) 

 

4001657 (NGZ) 

 

4001658 (NAC) 

 

4001659 (WUSA)

UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENT AVEC 

CETTE UNITE.

AVERTISSEMENT:

N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU 

DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI 

EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.

PRODUIT DÉCORATIF:

NE PAS UTILISER COMME APPARIEL DE CHAUFFAGE 

 *LES CONDITIONS DE BAISSE D’EVALUATION SELON L’ALTITUDE 

S’APPLIQUENT AU CANADA SEULEMENT

 

  

 

ALTITUDE / ELEVATION

 

(0-610m) (610-1370m) 

 

 

44,000 BTU/h 

40,000 BTU/h 

*INPUT / ALIMENTATION* 

 

20,000 BTU/h 

18,000 BTU/h 

REDUCED INPUT / ALIMENTATION REDUITE

 

33,000 BTU/h 

30,000 BTU/h 

OUTPUT(MODEL GDS50) RENDEMENT 

 

31,200 BTU/h 

28,400 BTU/h 

OUTPUT(MODEL GS50) RENDEMENT 

GS50-N

CS500-N

GS50-P

CS500-P

2000-4500FT

0-2000FT

2000-4500FT

0-2000FT

 (0-610m) 

 

40,000 BTU/h 

 

21,000 BTU/h 

 

30,400 BTU/h 

 

30,000 BTU/h 

26,400 BTU/h

27,400 BTU/h

18,000 BTU/h

36,000 BTU/h

(610-1370m)

*ALTITUDE DOWNRATING CONDITIONS APPLY 

TO CANADA ONLY /

P4 (NG/LP) / (GN/PL):

70% / 69.5%

70% / 69.5%

FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.

WARNING:

DO NOT ADD ANY MATERIAL TO THE APPLIANCE,

WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER THAN 

THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.

DECORATIVE PRODUCT:

NOT FOR USE AS A HEATING APPLIANCE

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL /

DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:

A

7"

D

17½"

B

2"

E

6¼"

C

1"

F

9½"

20" TO CEILING FROM STOVE TOP

20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND

ELECTRICAL RATING / CLASS.:

115V 1.5AMP 60HZ

NOT FOR USE WITH SOLID FUEL

UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE 

UTILSE AVEC CET APPAREIL

MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY. 

LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT.

B-VENT MODELS GS50/CS500

APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION. 
THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER 

KIT GS-150KT

.

B-VENT MODELS GS50/CS500

HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, & UN STUDIO.
CET APPAREIL DOIT ETRE INSTALLE EN UTILISANT UN ENSEMBLE ADAPTATEUR 

GS-150KT. 

For rating plate location, see "INSTALLATION OVERVIEW" section

INSTALLER:  It is your responsibility to check off the appropriate box on the rating plate according to 

the model, venting and gas type of the unit.

This illustration is for reference only.  Refer to the rating plate on the appliance for accurate information.

NOTE: This rating plate must remain with the appliance at all times. It must not be removed.

SAMPLE

SAMPLE

SAMPLE

CE / FOYER À GAZ V

CE / FOYER À GA

UATION DIRECTE. HOMOLOGU

ATION DIRECTE. HOMOLOG

TUDIO. APPROPRIE POUR INSTALLAT

UDIO. APPROPRIE POUR INST

GENCES DE LA NORME CAN/CSA  Z240MH S

ENCES DE LA NORME CAN/CSA  Z240MH S

AU CANADA OU AUX ETATS-UNIS DE LA NORME D

ADA OU AUX ETATS-UNIS DE LA NORME D

UREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS

 24 CFR, SECTION 3280. DANS LE CA

E REFERER A LA NORME RELATIVE AU CRITERE DE

RME RELATIVE AU CRITERE D

LATIONS DANS LES MAISONS MANUFACTURES, LE

NS MANUFACTURES, LE

UTILISER SEULMENT AVEC BARRIÈRE W565-0196. S

TILISER SEULMENT AVEC BARRIÈRE W565-0196. 

GDS50-P

GDS50-P

PLL

PROPANE MO

PROPANE MO

TD.

D.

OAD, BARRIE, ON, L4M 0G8 CANA

, BARRIE, ON, L4M 0G8 CANA

4001657 (NGZ) 

4001657 (NGZ

4001659 (WUSA)

01659 (WUSA)

P

ALTITUDE / ELEVATION

UDE / ELEVATION

ALTITUDE /

DE / 

*INPUT / ALIMENTATION*

*INPUT / ALIMENTATION* 

REDUCED INPUT / ALIMENTATION REDUITE

REDUCED INPUT / ALIMENTATION REDUIT

OUTPUT(MODEL GDS50) RENDEMENT

OUTPUT(MODEL GDS50) RENDEMENT 

OUTPUT(MODEL GS50) RENDEMENT

OUTPUT(MODEL GS50) RENDEMENT

GS50-P

50-P

PL

2000-450

 (0-6

ION

ION

 40

ON*

ON*

TION REDUITE

TION REDUIT

ENDEMENT

ENDEMENT 

NDEMENT

NDEMENT 

P4 (NG/LP) / (GN/PL):

P4 (NG/LP) / (GN/PL):

M CLEARANCE TO COMBUSTIBLE MATERIAL /

CLEARANCE TO COMBUSTIBLE MATERIAL /

AGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBL

NTS MINIMAUX DES MATERIAUX COMBUSTIB

A

7"

DD

17½"

17½"

B

2"

E

6¼"

6¼"

CC

1"

F

9½"

9½"

20" TO CEILING FROM STOVE TOP

20" TO CEILING FROM STOVE TOP

20" ENTRE LE DESSUS DU FOYER ET LE 

20" ENTRE LE DESSUS DU FOYER ET LE

ELECTRICAL RATING / CLASS.:

ELECTRICAL RATING / CLA

115V 

115V

MINIMUM AND MAXIMUM HORIZONTAL VE

MINIMUM AND MAXIMUM HORIZONTAL V

LES LONGUEURS HORIZONTALES MIN

S LONGUEURS HORIZONTALES M

ION.

ER

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the 

appliance and shall be installed.

Summary of Contents for GS 50 - N

Page 1: ...of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplie...

Page 2: ...H EXISTING CHIMNEY 25 4 3 B VENT INSTALLATION GS50 26 4 3 1 CHIMNEY INSTALLATION 26 4 3 2 INSTALLING FLASHING AND STORM COLLAR 26 4 3 3 ADDING VENT SECTIONS 27 4 3 4 INSTALLING NATURAL VENT 27 4 3 5 N...

Page 3: ...0 INSTALLATION OVERVIEW SAFETY BARRIER Venting see VENTING section Door see DOOR OPENING AND CLOSING section Trivet see TRIVET INSTALLATION section Logs see LOG PLACEMENT section Rating plate see RATI...

Page 4: ...r no circumstances should this appliance be modified This appliance must not be connected to a chimney ue pipe serving a separate solid fuel burning appliance Do not use this appliance if any part has...

Page 5: ...15 1427 A 09 27 17 5 EN 2 1 DIMENSIONS GAS LINE LOCATED IN PEDESTAL REAR 281 4 718mm 141 8 359mm 215 8 549mm 8 203mm 7 178mm AIRINTAKE 4 102mm FLUE 133 4 349mm 21 533mm 303 4 781mm SAFETY BARRIER 2 51...

Page 6: ...cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood...

Page 7: ...ions and is suitable for mobile homes The natural gas model is suitable for installation in a mobile home that is permanently positioned on its site and fueled with natural gas GS50 This appliance is...

Page 8: ...TU h OUTPUT MODEL GS50 RENDEMENT GS50 N CS500 N GS50 P CS500 P 2000 4500FT 0 2000FT 2000 4500FT 0 2000FT 0 610m 40 000 BTU h 21 000 BTU h 30 400 BTU h 30 000 BTU h 26 400 BTU h 27 400 BTU h 18 000 BTU...

Page 9: ...F 204 C Application and performance of paint is the consumer s responsibility Spot testing is recommended NOTE If for any reason the vent air intake system is disassembled reinstall per the instructi...

Page 10: ...venting included or 1 12 to 7 12 pitch roof terminal kit GD110 8 12 to 12 12 roof terminal kit GD111 at roof terminal kit GD112 or periscope kit GD180 for wall penetration below grade in conjunction w...

Page 11: ...CAL VENT INSTALLATION 16 406mm MINIMUM 40 FT 12m MAXIMUM 36 914mm MINIMUM 30 3 4 781mm 59 3 4 1518mm MINIMUM PLUS RISE 34 864mm MAXIMUM See VENTING section 29 737mm MINIMUM 30 3 4 781mm 86 4cm 73 7cm...

Page 12: ...isez l ensemble p riscopique afin de positionner la terminaison au dessus du niveau du sol L ensemble p riscopique doit tre install de fa on ce que la fente d air du bas soit situ e un minimum de 12 p...

Page 13: ...ce to a mechanical air supply inlet L 7 2 1m 7 2 1m Clearance above a paved sidewalk or paved driveway located on public property M 12 30 5cm 12 30 5cm Clearance under a veranda porch or deck N 16 40...

Page 14: ...times the vertical rise equal to or greater than the horizontal run maximum of 40 feet 12m maximum of 40 feet 12m 14 1 For the following symbols used in the venting calculations and examples are grea...

Page 15: ...H1 2 5 FT 0 8m H2 2 FT 0 6m HR H1 H2 2 5 FT 0 8m 2 FT 0 6m 4 5 FT 1 4m HO 03 three 90 elbows 90 03 270 90 5 4 FT 1 7m HT HR HO 4 5 FT 1 4m 5 4 FT 1 7m 9 9 FT 3m HT VT 9 9 FT 3m 11 FT 3 4m 20 9 FT 6 4m...

Page 16: ...7FT 5 1m 24 75 FT 7 5m Since both formulas are met this vent configuration is acceptable HORIZONTAL VENT RUN PLUS OFFSET IN FEET METERS HT The shaded area within the lines represents acceptable value...

Page 17: ...feet 12 2m Example V1 5 FT 1 5m V2 6 FT 1 8m V3 10 FT 3 1m VT V1 V2 V3 5FT 1 5m 6FT 1 8m 10FT 3 1m 21FT 6 4m H1 8 FT 2 4m H2 2 5 FT 0 8m HR H1 H2 8FT 2 4m 2 5FT 0 8m 10 5 FT 3 2m HO 03 four 90 elbows...

Page 18: ...6FT 1 8m 2FT 0 6m 8 FT 2 4m HO 03 four 90 elbows 90 03 360 90 8 1 FT 2 5m HT HR HO 8FT 2 4m 8 1FT 2 5m 16 1FT 4 9m HT VT 16 1FT 4 9m 4 5FT 1 4m 20 6 FT 6 3m Formula 1 HT 3VT 3VT 3FT 0 9m x 4 5FT 1 4m...

Page 19: ...pe on both horizontal and vertical runs to combustibles is required W415 1427 12 23 14 18 EN 4 0 INSTALLATION WARNING ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP T...

Page 20: ...ENCLOSURE WITH ANY TYPE OF MATERIAL DO NOT PACK INSULATION OR COMBUSTIBLES BETWEEN CEILING FIRESTOPS ALWAYS MAINTAIN SPECIFIED CLEARANCES AROUND VENTING AND FIRESTOP SYSTEMS INSTALL WALL SHIELDS AND F...

Page 21: ...l vent pipe shield plate or equivalent in the case of a finished ceiling and secure over the opening in the ceiling A firestop must be placed on the bottom of each framed opening in a roof or ceiling...

Page 22: ...eeded for the nished wall surface Apply a heavy bead of the high temperature sealant W573 0007 Mill Pac not supplied to the inner sleeve of the air terminal Slip the vent pipe a minimum of 2 50 8mm ov...

Page 23: ...over the air terminal connector leaving a min 3 4 19mm of the air terminal connector showing above the top of the ashing Slide the ashing underneath the sides and upper edge of the shingles Ensure th...

Page 24: ...ealant W573 0007 Mill Pac not supplied C Run a bead of high temperature sealant not supplied around the inside of the air intake collar Pull the adjustable pipe a minimum 2 50 8mm into the air intake...

Page 25: ...NOTE A vent adaptor will be required directly off the appliance Follow vent manufacturer s installation instructions Different manufacturer s venting components must not be combined Once the preferred...

Page 26: ...t 0 3m Three types of chimney systems may be used with this appliance 88 1A Remove the nails from the shingles above and to the sides of the chimney Place the ashing over the chimney pipe and slide un...

Page 27: ...ive black band standard with the GS150KT Both are available from your local authorized dealer distributor W415 1427 12 23 14 26 EN 4 3 3 ADDING VENT SECTIONS Add chimney sections according to the manu...

Page 28: ...al block F Attach the black on off switch wire with the 3 16 tab to the other side of the terminal block Connect the remaining wires 1 black 1 white with 1 4 connectors to TP TH and TH on the gas valv...

Page 29: ...RE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS...

Page 30: ...RMOSTAT OR GAS VALVE DIRECTLY TO 110 VOLT ELECTRICITY 4 5 WALL SWITCH INSTALLATION GS50 Disconnect the existing on off switch wire from terminal 1 on the valve and the black switch wire from the termi...

Page 31: ...S ARE HEAVY AND FRAGILE SO HANDLE WITH CARE 75 3 A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and must be installed Open the side panels and...

Page 32: ...d when securing the door HANDLE CATCH 5 2 DOOR OPENING AND CLOSING W415 1427 12 23 14 31 EN WARNING RISK OF FIRE NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE DO NOT STRIKE SLAM OR SCRATCH GLASS D...

Page 33: ...FAILURE TO USE ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE DO NOT MODIFY THE PROPE...

Page 34: ...emove the backing of the logo supplied and centre over the logo installation holes as indicated 5 5 TRIVET INSTALLATION Insert the trivet into the space on the appliance top Line up the holes in the b...

Page 35: ...burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless th...

Page 36: ...riction If necessary consult with a qualified inspector 6 2 TURBO BURNER OPERATION 6 3 SPILL SWITCH GS50 ONLY W415 1427 12 23 14 35 EN The purpose of the turbo burner is to increase heat output of BTU...

Page 37: ...ONT BURNER REAR BURNER NG 1 4 6 4mm 1 2 13mm P 1 4 6 4mm 1 2 13mm W415 1427 12 23 14 36 EN 7 0 ADJUSTMENTS 7 1 PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized ame Turn in a cl...

Page 38: ...not burning properly D Check to see that the pilot flame is large enough to engulf the flame sensor and or thermocouple thermopile as well as reaches the burner E Replace the cleaned logs rocks or gl...

Page 39: ...ions for pre cleaning Also gently remove any build up on the pilot assembly including if equipped thermopile thermocouple flame sensor and igniter NOTE Clean ame sensor using a fine emery cloth or a s...

Page 40: ...ors G Turn the gas supply and electricity back on Because the blower is thermally activated when turned on it will automatically start approximately 15 30 minutes after lighting the appliance and will...

Page 41: ...cement parts always give the following information Model Serial Number of appliance Installation date of appliance Part number Description of part Finish IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR...

Page 42: ...ATCH X2 W430 0002 LOG 3 RIGHT SIDE LOG GL 642 LEFT SIDE DOOR ASSEMBLY W135 0196 W010 3526 W010 1265 VALVE TRAIN ASSEMBLY W357 0001 PIEZO IGNITER LOG 4 LEFT CHUNK GL 642 W135 0197 CHARCOAL EMBERS GL 64...

Page 43: ...010 0800 PILOT P W010 0798 PILOT ASSEMBLY NG W010 0799 PILOT ASSEMBLY P W720 0062 PILOT TUBE w FITTINGS W240 0006 SER ELECTRODE w WIRE W290 0029 PILOT GASKET YES YES YES YES YES YES YES YES YES 14 14...

Page 44: ...96 SAFETY BARRIER ASSEMBLY GS350 W300 0028 LEFT AND RIGHT SIDE GLASS PANEL 12 22 14 3 1 STOCKED W225 0086G GOLD DOOR FRAME GS350 W135 0148 CAST IRON ANDIRONS X2 W562 0009 GASKET KIT W225 0086 METALLIC...

Page 45: ...switch terminals if main burner lights replace switch thermostat Wall switch wiring is defective Disconnect the switch wires connect a jumper wire across terminals 1 3 if the main burner lights check...

Page 46: ...ed Ensure air shutter opening is free of lint or other obstructions Flame is impinging on the logs or combustion chamber Check that the logs are correctly positioned Open air shutter to increase the p...

Page 47: ...ff and front burner to low When blower turns on re adjust burners Door sticking Dirt dust adheres to the hinges is heated and burns causing sticking Lift door from its hinges Lubricate with high temp...

Page 48: ...dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under the President s Limited Lifetime Warranty Policy are subject to a single claim...

Page 49: ...W415 1427 A 09 27 17 49 EN 15 0 SERVICE HISTORY 43 1...

Page 50: ...ORT PRODUCTS 7200 Route Transcanadienne Montr al Qu bec H4T 1A3 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden Kentucky USA...

Page 51: ...l doit tre utilis uniquement avec le type de gaz indiqu sur la plaque signal tique Cet appareil ne peut tre converti d autres gaz sauf si une trousse de conversion est utilis e Si ces instructions ne...

Page 52: ...DE L VENT DE TYPE B GS50 76 4 3 1 INSTALLATION DE LA CHEMIN E 76 4 3 2 INSTALLATION DU SOLIN ET DU COLLET DE SOLIN 76 4 3 3 AJOUT DE SECTIONS D VENTS 77 4 3 4 INSTALLATION DE L VENT TIRAGE NATUREL 78...

Page 53: ...ECTION vacuation voir la section VACUATION Porte voir la section OUVERTURE ET FERMETURE DE LA PORTE Grille voir la section INSTALLATION DE LA GRILLE B ches voir la section DISPOSITION DES B CHES Plaqu...

Page 54: ...ant des tapis literie etc L emplacement de l appareil doit tre gard libre de tous mat riaux combustibles essence ou autres liquides et vapeurs inflammables Cet appareil ne devra tre modifi en aucun ca...

Page 55: ...27 09 27 17 FR 2 1 DIMENSIONS CONDUITE DE GAZ SITU E L ARRI RE DU PI DESTAL PRISED AIR BUSE 281 4 718mm 141 8 359mm 215 8 549mm 8 203mm 7 178mm 4 102mm 133 4 349mm 21 533mm 303 4 781mm 2 51mm CRAN DE...

Page 56: ...d couper des solives de plancher ou de toit Si l appareil est install directement sur un tapis sur une surface de vinyle ou tout autre rev tement de plancher combustible autre que le bois l appareil d...

Page 57: ...r installation dans les maisons mobiles Le mod le au gaz naturel peut tre install dans une maison mobile install e en permanence et aliment e au gaz naturel GS50 Cet appareil est approuv pour installa...

Page 58: ...UTEZ PAS A CETAPPAREILAUCUN MATERIAU DEVANT ENTRER EN CONTACTAVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CETAPPAREIL PAR LE FABRICANT PRODUIT D CORATIF NE PAS UTILISER COMME APPARIEL DE CHAUF...

Page 59: ...rsque les murs int rieurs le plancher ou le plafond sont travers s NOTE Si pour une raison quelconque le syst me d vents de prise d air est d mont r installez le selon les instructions fournies dans l...

Page 60: ...nduits inclus ou ensemble de terminaison pour toit de pente 1 12 7 12 GD110 ensemble de terminaison pour toit de pente 8 12 12 12 GD111 ensemble de terminaison pour toit plat GD112 ou ensemble p risco...

Page 61: ...r la section VACUATION 16 406mm MINIMUM 40 FT 12m MAXIMUM 36 914mm MINIMUM 30 3 4 781mm 59 3 4 1518mm MINIMUM PLUS L L VATION 34 864mm MAXIMUM 29 737mm MINIMUM 30 3 4 781mm 63 W415 1427 01 06 15 FR 86...

Page 62: ...t situ e un minimum de 12 pouces 30 5cm au dessus du niveau du sol La longueur maximale permise de l vent est 10 pieds 3 1m pour un foyer et 8 pieds 2 4m pour un po le 9 1B 3 3 INSTALLATIONS PARTICULI...

Page 63: ...3 0 9m Voir le tableau pour les dimensions d un mur plus large R 6 1 8m 6 1 8m Voir le tableau pour les dimensions d un mur plus profond La terminaison ne doit pas tre install e sur quelconque mur aya...

Page 64: ...izontale 3 fois la course verticale plus grande ou gale la course horizontale VACUATION SUR LE DESSUS 14 1 Les symboles suivants sont utilis s dans le calcul et les exemples d vacuation plus grand que...

Page 65: ...T VT 9 9 PI 3m 11 PI 3 4m 20 9 PI 6 4m Formule 1 HT VT 9 9 PI 3m 11 PI 3 4m Formule 2 HT VT 40 PI 12 2m 20 9 PI 6 4m 40 PI 12 2m Puisque les deux formules sont respect es cette configuration d vacuati...

Page 66: ...Formule 2 HT VT 24 75 PI 7 5m 16 7PI 5 1m 24 75 PI 7 5m Puisque les deux formules sont respect es cette configuration d vacuation est acceptable Exemple V1 4 PI 1 2m V2 1 5 PI 1 5m VT V1 V2 4 PI 1 2m...

Page 67: ...PI 1 8m V3 10 PI 3 1m VT V1 V2 V3 5PI 1 5m 6PI 1 8m 10PI 3 1m 21 PI 6 4m H1 8 PI 2 4m H2 2 5 PI 0 8m HR H1 H2 8 PI 2 4m 2 5 PI 0 8m 10 5 PI 3 2m HO 0 03 quatre coudes 90 90 0 03 360 90 8 1 PI 2 5m HT...

Page 68: ...atre coudes 90 90 0 03 360 90 8 1 PI 2 5m HT HR HO 8 PI 2 4m 8 1 PI 2 5m 16 1 PI 4 9m HT VT 16 1PI 4 9m 4 5PI 1 4m 20 6 PI 6 3m Formule 1 HT 3VT 3VT 3PI 0 9m x 4 5PI 1 4m 13 5 PI 4 1m 16 1 PI 4 9m 13...

Page 69: ...ux combustibles sont respect es le meilleuwwr endroit pour un appareil est le centre de la maison car ceci permet une meilleure utilisation de la chaleur fournie L emplacement des fen tres des portes...

Page 70: ...L ESPACEUR COUPE FEU DOIT TRE INSTALL AVEC L CRAN PROTECTEUR ORIENT VERS LE HAUT LA TERMINAISON NE DOIT PAS TRE ENCH SS E DANS LE MUR OU LE REV TEMENT EXT RIEUR PLUS QUE L PAISSEUR DE LA BRIDE DE LA...

Page 71: ...fond ni et xez le protecteur de conduit d vacuation de fa on recouvrir l ouverture dans le plafond Un espaceur coupe feu doit tre x la base de chaque ouverture charpent e dans un toit ou un plafond pa...

Page 72: ...vement Utilisez des supports incombustibles afin de maintenir le d gagement minimal aux mat riaux combustibles La plaque de montage de la terminaison peut tre ench ss e dans le mur ou le rev tement ex...

Page 73: ...in Glissez le solin sous les c t s et le bord sup rieur des bardeaux Assurez vous que le connecteur de terminaison est bien centr dans le solin en laissant une marge de 3 4 19 1mm tout autour Fixez le...

Page 74: ...haute temp rature non fourni l int rieur de la buse de prise d air Glissez le conduit t lescopique l int rieur de la buse de prise d air sur une longueur d au moins 2 50 8mm NOTE Assurez vous que le...

Page 75: ...a n cessaire directement partir de l appareil Suivez les instructions d installation du fabricant du syst me d vacuation Des composants d vacuation de diff rents fabricants ne doivent pas tre combin s...

Page 76: ...doivent avoir une l vation minimale de 1 4 6 4mm par pied 0 3m Trois types de syst mes de chemin e peuvent tre utilis s avec cet appareil 88 1A Enlevez les clous des bardeaux sur le dessus et les c t...

Page 77: ...iture et 2 0 6m de tout mur toit ou difice se trouvant l int rieur d une distance horizontale de 10 3 1m 59 1B 3 PI 1m MIN 3 PI 1m MIN 10 PI 3m OU PLUS TOIT PLAT MUR FA TE MOINS DE 10 PIED 3m 2 PI 0 6...

Page 78: ...orairement les deux bornes ensemble avec du ruban adh sif Avec l ouverture de l interrupteur d coulement align e avec l arri re de l appareil tenez l adaptateur par la base et ins rez le rebord gaufr...

Page 79: ...de 3 16 sur l autre c t du bloc de branchement Branchez les autres fils 1 noir et 1 blanc muni d un connecteur 1 4 6 4mm aux bornes TP TH et TH de la soupape de gaz G Remettez en place et refixez le...

Page 80: ...n fil provenant de l interrupteur d coulement fil blanc la borne 3 situ e sur la soupape de gaz et l autre noir provenant de l interrupteur marche arr t la borne 1 de la soupape Fixez l tiquette d vac...

Page 81: ...orne 1 de la soupape de gaz et le fil noir de l interrupteur du bloc de branchement et remplacez les par les deux fils de l interrupteur mural thermostat millivolt Au Canada l installation de l vacuat...

Page 82: ...SONT LOURDES ET FRAGILES MANIPULEZ AVEC SOIN 75 3 Une barri re con u r duire le risque de br lures partir de le chaude la vitre est condition que avec l appareil et sera tre install s Ouvert les pann...

Page 83: ...ITR E EST ENLEV E FISSUR E BRIS E OU GRATIGN E 72 4 85 W415 1427 01 06 15 FR Lorsque vous ouvrez la porte vitr e une simple proc dure doit tre suivie pour viter d endommager la porte Ouvrez la porte d...

Page 84: ...BLESSURES CORPORELLES LES B CHES DOIVENT TRE PLAC ES CORRECTEMENT L INT RIEUR DE L APPAREIL NE CHANGEZ PAS LA POSITION DES B CHES CAR L APPAREIL RISQUE DE NE PAS FONCTIONNER AD QUATEMENT ET UN RETARD...

Page 85: ...LOGO Retirez le papier dorsal et placez le logo de fa on camoufler les trous comme indiqu 5 5 INSTALLATION DE LA GRILLE Ins rez la grille dans l espace sur le dessus de l appareil Alignez les trous de...

Page 86: ...refroidir Durant l allumage et le r allumage le bouton de contr le du gaz ne peut tourner de PILOT OFF moins de l enfoncer l g rement 1 Arr tez Lisez les consignes de s curit ci dessus 2 Coupez l alim...

Page 87: ...teur qualifi 6 1 INSTRUCTIONS D OP RATION 6 2 OP RATION DU BR LEUR TURBO 6 3 INTERRUPTEUR D COULEMENT GS50 SEULEMENT 89 FR Le br leur turbo sert accro tre le d bit de chaleur de l appareil Il ne fonct...

Page 88: ...UPLE ET DE LA THERMOPILE DE 3 8 1 2 9 5mm 12 7mm 88 W415 1427 09 27 17 FR 7 0 R GLAGES 7 1 R GLAGE DE LA VEILLEUSE BR LEUR AVANT BR LEUR ARRI RE GN 1 4 6 4mm 1 2 13mm P 1 4 6 4mm 1 2 13mm Ajustez la v...

Page 89: ...pots de carbone qui peuvent se d poser dans des endroits de s jour avoisinants F V ri ez si le br leur principal allume sur tous les ori ces lorsque le bouton de contr le du gaz est ON Un temps d all...

Page 90: ...ons de pr nettoyage Enlevez aussi tout d p t se trouvant sur l assemblage de la veilleuse et aussi s il y a lieu sur la thermopile le thermocouple le capteur de amme et l allumeur NOTE Vous devrez pos...

Page 91: ...s b ches C Retirez la porte d vacuation de pression retenue par 6 vis Enlevez le joint d tanch it D D branchez les deux fils de la soufflerie Enlevez le support de la soufflerie en d vissant les 4 vis...

Page 92: ...s rie de l appareil Date d installation de l appareil Num ro de la pi ce Description de la pi ce Fini IDENTIFIE LES ARTICLES QUI NE SONT PAS ILLUSTR S POUR PLUS D INFORMATION CONTACTEZ VOTRE D TAILLA...

Page 93: ...642 ASSEMBLAGE DE LA PORTE DU C T GAUCHE W135 0196 W010 3526 W010 1265 L ASSEMBLAGE DE LA SOUPAPE W357 0001 ALLUMEUR PIEZO PIECE GAUCHE B CHE 4 GL 642 W135 0197 BRAISES DE CHARBON GL 642 BASE DU B CHE...

Page 94: ...0799 ASSEMBLAGE DE VEILLEUSE P W720 0062 TUBE DE VEILLEUSE RACCORD W240 0006 SER ELECTRODE AVEC FILS W290 0029 JOINT D TANCH IT DU VEILLEUSE OUI OUI OUI OUI OUI OUI OUI OUI OUI 14 14 14 14 14 14 14 14...

Page 95: ...225 0086 W225 0086SC 49 50 51 52 53 OUI W300 0029 W030 0021G BARRE D ACCENT OR W030 0021SC BARRE D ACCENT CHROME SATIN 49 49 THERMOSTAT MURAL NUM RIQUE T L COMMANDE MANUELLE L ASSEMBLAGE DU L CRAN DE...

Page 96: ...cipal le bouton du gaz est HI l interrupteur mural thermostat est ON Le thermostat ou l interrupteur sont d fectueux Reliez un fil de d rivation entre les bornes de l interrupteur mural si le br leur...

Page 97: ...me ci dessous Assurez vous que le br leur prinicpal fonctionne HI APR S AVOIR PRIS LA LECTURE DES PRESSIONS ASSUREZ VOUS DE TOURNER FERMEMENT LA VIS VERS LA DROITE POUR SCELLER NE SERREZ PAS TROP FORT...

Page 98: ...br leur avant LOW Lorsque la soufflerie se met en marche r ajustez les br leurs La porte se coince La poussi re salet adh re aux charni res elle est chauff e et br le coin ant ainsi la porte Enlevez...

Page 99: ...uits d entretien nuisibles ne seront pas la responsabilit de NAPOL ON Toutes les pi ces remplac es en vertu de la politique de Garantie vie limit e du Pr sident ne peuvent faire l objet que d une seul...

Page 100: ...ON DE PRODUITS DE CONFORT 7200 Route Transcanadienne Montr al Qu bec H4T 1A3 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden...

Reviews: