W415-1427 / A / 09.27.17
28
EN
Refer to "DOOR OPENING AND CLOSING" section
prior to proceeding to prevent damaging the appliance.
A.
Remove both burners and the log support
bracket.
B.
Remove the combustion air cover plate and its
gasket. THE TWO SCREWS MUST BE RE-
SECURED.
C.
Undo the bracket holding the thermodisc, turn
90° as shown and reattach to the weld stud
located on the right air manifold side.
NOTE: Do not tighten the wing nut until
burner is installed; then ensure that the
thermodisc firmly touches the underside of
the burner tray and tighten. This enables the
blower to function properly.
D.
Secure the terminal block into place as shown
with the screw supplied.
E.
Gently pull the two white spill switch wires
to take up any slack. Feed these wires down
through the combustion air opening and back
up through the 4x6 inch cut-out in the base.
Connect the shorter of the 2 wires to the
terminal block.
F.
Attach the black on/off switch wire with the
3/16" tab to the other side of the terminal block.
Connect the remaining wires (1 black - 1 white)
with 1/4" connectors to TP/TH and TH on the
gas valve.
G.
Replace and re-secure the log support bracket
and the two burners ensuring that each venturi
fits over the burner orifice.
4.3.5 NATURAL VENT ADAPTATIONS
TURBO
VIEWING
COMBUSTION AIR
COVER PLATE
MIRROR
REAR BURNER
FRONT BURNER
LOG SUPPORT BRACKETS
4.3.6 COMBUSTION AIR
If using outside air, connections can be made through a hole in the floor to line up with the hole in the pedestal
base. Use a fresh air kit available through your local authorized dealer / distributor. Secure the 4" (102mm)
diameter aluminum liner to the hole in the base of the pedestal. Avoid cutting away floor joist, electrical wiring
or plumbing. Seal around the outside pipe with insulation to prevent drafts.
ANY APPLIANCE NEEDS AIR FOR SAFE OPERATION AND MUST BE INSTALLED IN SUCH A WAY
THAT ADEQUATE COMBUSTION AIR IS AVAILABLE. THIS APPLIANCE IS DESIGNED TO FUNCTION
USING EITHER OUTSIDE OR INSIDE (ROOM) AIR.
!
WARNING