Napoleon GD27 - N Installation And Operation Instructions Manual Download Page 4

4

WS-415-090 / 04.03.00

CARE OF GLASS, AND PLATED PARTS

Do not use abrasive cleaners to clean plated parts. Buff
lightly with a clean dry cloth. The glass is 3/16" ceramic
glass available from your Napoleon / Wolf Steel Ltd. dealer.
DO NOT SUBSTITUTE MATERIALS. Clean the glass after
the first 10 hours of operation with a recommended gas
fireplace glass cleaner. Thereafter clean as required. DO
NOT CLEAN GLASS WHEN HOT! If the glass is not kept
clean permanent discolouration and / or blemishes may
result.

No external electricity (110 volts or 24 volts) is
required for the gas system operation.
Purge all gas lines with the glass door of the fire-
place removed. Assure that a continuous gas flow
is at the burner before installing the door.
Under extreme vent configurations, allow several
minutes (5-15) for the flame to stabilize after igni-
tion.
Six inches is the minimum bend radius allowed for
the 7" diameter flexible liner.
Provide adequate ventilation air. Provide adequate
accessibility clearance for servicing and operat-
ing the fireplace. Never obstruct the front opening
of  the fireplace.
Objects placed in front of the fireplace must be
kept a minimum of 48" from the front face of the
unit.
Expansion / contraction nosies during heating up
and cooling down cycles are normal and are to be
expected.

GENERAL INSTRUCTIONS

THIS GAS FIREPLACE SHOULD BE INSTALLED AND
SERVICED BY A QUALIFIED INSTALLER

  to conform with

local codes. In absence of local codes, install to the cur-
rent CAN/CGA -B149 Installation Code in Canada or to the
National Fuel Gas Code, ANSI Z223.1-1988, and NFPA
54-1988 in the United States. Mobile home installation
must conform with local codes or in the absence of  local
codes, install to the current standard for gas equipped
mobile housing CAN/CSA ZA240 MH Series in Canada or
ANSI Z223.1-1988 and NFPA 54-1988 in the United States.

The fireplace and its individual shutoff valve must be dis-
connected from the gas supply piping system during any
pressure testing of that system at test pressures in ex-
cess of 1/2 psig (3.5 kPa). The fireplace must be isolated
from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the
gas supply piping  system at test pressures equal to or
less than 1/2 psig (3.5 kPa).

If the optional fan or blower is installed, the junction box
must be electrically connected and grounded in accordance
with local codes. In the absence of local codes, use the
current CSA C22.1 CANADIAN ELECTRICAL CODE in
Canada or the ANSI/NFPA 70-1996 NATIONAL ELECTRI-
CAL CODE in the United States.

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN
TEST-FIRED TO ASSURE ITS OPERATION AND QUAL-
ITY!

  Maximum input is 27,000 BTU/hr for natural gas and

propane. When the fireplace is installed at elevations above
4,500ft, and in the absense of specific recommendations
from the local authority having jurisdiction, the certified high
altitude input rating shall be reduced at the rate of 4% for
each additional 1,000ft. Maximum output for natural gas is
23,220 BTU/hr at an efficiency of 86% with the fan on, and
23,814 BTU/hr for propane at an efficiency of 88% with the
fan on. Minimum A.F.U.E. (annual fuel utilization efficiency)
rating is 64% for natural gas and 65% for propane.

Minimum inlet gas supply pressure is 4.5 inches water
column for natural gas and 11 inches water column for
propane. Maximum inlet gas pressure is 7 inches water
column for natural gas and 13 inches water column for
propane. Manifold pressure under flow conditions is 3.5
inches water column for natural gas and 10 inches water
column for propane.

This fireplace is approved for bathroom, bedroom and bed-
sitting room installations and is suitable for mobile home
installation. The natural gas model can only be installed in
a mobile home that is permanently positioned on its site
and fueled with natural gas.

FIGURE 1

Summary of Contents for GD27 - N

Page 1: ...nnot reach your gas supplier call the fire department LISTED DIRECT VENT MILLIVOL LISTED DIRECT VENT MILLIVOL LISTED DIRECT VENT MILLIVOL LISTED DIRECT VENT MILLIVOL LISTED DIRECT VENT MILLIVOLT T T T...

Page 2: ...should be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near the fireplace Any safety screen or guard removed for servic...

Page 3: ...ver requires the prior approval of an authorized company official Labour costs to the account of to the account of to the account of to the account of to the account of NAPOLEON NAPOLEON NAPOLEON NAPO...

Page 4: ...States The fireplace and its individual shutoff valve must be dis connected from the gas supply piping system during any pressure testing of that system at test pressures in ex cess of 1 2 psig 3 5 kP...

Page 5: ...When terminating vertically the vertical rise is a minimum 3 feet and a maximum 40 feet above the fireplace For safe and proper operation of the fireplace follow the ventinginstructionexactly Deviati...

Page 6: ...llow ing procedure for vent length calculations must be followed In an installation as shown in FIGURE 5 lengths A and C are known based on room height and roof re quirements Any 90 and 45 elbows must...

Page 7: ...ET Clearance above grade veranda porch deck or balcony Clearance to windows or doors that open Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the termina...

Page 8: ...nded that For optimum performance it is recommended that For optimum performance it is recommended that all horizontal runs have a minimum inch rise all horizontal runs have a minimum inch rise all ho...

Page 9: ...e fireplace vent collar and secure with 3 8 screws 2 Using the 7 diameter flexible aluminum liner apply sealant slide a minimum of 2 over the fireplace combus tion air collar and secure with 3 8 screw...

Page 10: ...rminal and down to the caulk ing Tighten to ensure that a weather tight seal between the air terminal and the collar is achieved Attach the other storm collar centered between the air intake and the a...

Page 11: ...ons for Horizontal Air Terminal In stallations 2 Continue adding components alternating inner and outer venting Ensure that all 4 vent ing and elbows have sufficient vent spacers attached and each com...

Page 12: ...vary according to the mantle depth FIGURES 26 Use the graph to help evaluate the clearance needed MOBILE HOME INSTALLATION In Canada mobile home installation may be vented hori zontally or vertically...

Page 13: ...ROPERLY WILL CAUSE FLAMEIMPINGEMENTANDCARBONING Log colours may vary During the initial use of the fireplace the colours will become more uniform as colour pigments burn in during the heat activated c...

Page 14: ...S 31 Optional plated door trim door side trim webbed facias arched door facias and bay door kits are available at your local Napoleon Wolf Steel dealer DOOR LOUVRE AND TRIM REMOVAL INSTALLATION Ensure...

Page 15: ...E OFFSET FIGURE33 red white b l a c k FIGURE32 FIGURE37 RECEPTACLE THERMODISC GROUND SCREW JUNCTION BOX FIGURE36 Attach the connectors from the black and white wires to the thermodisc and secure the t...

Page 16: ...E FIGURE39 FIGURE38 FIGURE40 FIGURE41 ELECTRICAL INSTALLATION TO BE DONE BY A QUALI FIED INSTALLER and must be connected and grounded in accordance with local codes In the absence of local codes use t...

Page 17: ...RUCTIONS When lit for the first time the fireplace will emit a slight odour for a few hours This is a normal temporary condi tion caused by the curing of the logs and the burn in of internal paints an...

Page 18: ...ad to carboning Opening the air shutter will cause a more blue flame but can cause flame lifting from the burner ports The flame may not appear yellow immediately allow 15 to 30 minutes for the final...

Page 19: ...NO DESCRIPTION GD 225 36 BLACK DOOR FRAME WS 300 20 GLASS ONLY GD 010 402 GLASS c w GASKET GD 321 K BLACK DOOR C W GLASS GD 562 09 DOOR GASKET 100 INCHES WS 455 11 40 NATURAL GAS ORIFICE WS 455 033 5...

Page 20: ...3 TRIM KIT POLISHED BRASS GD3C 3 TRIM KIT CHROME GD6AB 6 TRIM KIT ANTIQUE BRASS GD6PB 6 TRIM KIT POLISHED BRASS GD6C 6 TRIM KIT CHROME GD43AB 4 3D TRIM KIT ANTIQUE BRASS GD43PB 4 3D TRIM KIT POLISHED...

Page 21: ...n around the thermocouple Pilot flame is not engulfing the thermocouple Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace thermocouple replac...

Page 22: ...are very active Flames are con sistently too large or too small Carboning occurs check pressure readings Inlet pressure can be checked by turning screw A counter clockwise 2 or 3 turns and then placi...

Page 23: ...23 WS 415 090 04 03 00 NOTES...

Reviews: