15
WS-415-090 / 04.03.00
INSTALLATION TO BE DONE BY A QUALIFIED IN-
STALLER
and must be electrically connected and
grounded in accordance with local codes. In the absence
of local codes, use the current CSA C22.1
CANADIAN
ELECTRI
-
CAL
CODE
in Canada or the ANSI/NFPA 70-1996
NATIONAL
ELEC
-
TRICAL
CODE
in the United States
If the fireplace was not previously equipped with a
blower:
route a grounded 2-wire, 60hz power cable to the
receptacle / junction box. At this point, it must be strain
relieved and insulated.
The three slots in the
mounting bracket
allow ease of adjust-
ment when attaching
the blower. For a
quiet running blower,
do not allow the as-
sembly to sit on the
firebox base.
Slide the vibration reducing pad
(A)
into the clip
(C)
and
onto the threaded stud
(B)
at the other end, piercing a hole
into the pad. The blower must be able to be positioned
entirely onto the pad.
Tilt the blower onto its side. Slide it past the controls and
into the clip
(C)
. Secure to the threaded stud using the lock
washer and wing nut provided. Ensure that the blower
does not touch the fireplace base or the firebox.
C
NOTE
OFFSET
FIGURE 33
red
white
black
FIGURE 32
FIGURE 37
RECEPTACLE /
THERMODISC
GROUND
SCREW
JUNCTION BOX
FIGURE 36
Attach the connectors from the black and white wires to the
thermodisc and secure the thermodisc bracket to the se-
curing stud at the bottom left of the unit using a lock washer
and wing nut. Ensure that the thermodisc touches the fire-
box wall.
Attach the connectors from the black and red wires to the
blower.
Attach and secure the variable speed switch using the nut
provided. Plug the harness cord into the receptacle.
OPTIONAL BLOWER INSTALLATION
FIGURE 35
FIGURE 34
C
C
A
B
The wire harness provided in this kit is a universal
harness. When installed, ensure that any excess
wire is contained, preventing it from making con-
tact with moving or hot objects.
Drywall dust will penetrate into the blower bear-
ings, causing irreparable damage. Care must be
taken to prevent drywall dust from coming into
contact with the blower or its compartment. Any
damage resulting from this condition is not cov-
ered by the warranty policy.
Because the blower is thermally activated, when
turned on, it will automatically start approximately
10 minutes after lighting the fireplace and will run
for approximately 30-45 after the fireplace has
been turned off. Use of the fan increases the out-
put of heat.