7
W415-0496 / B / 08.10.05
BLOWER INSTALLATION
Blower (
SEE
LOCATION
AND
CLEARANCES
)
1.
Cut and remove the tie securing the blower switch wires
to the heat shield.
2.
Connect the white wire coming from below the unit to the
terminal on the blower.
3.
Connect the black blower wire to the black wire coming
from below the unit.
4.
Insert the clips on the blower housing into the cutouts in
the rear shield. Push down to lock the clips into position.
5.
Secure the blower using the screw and lock washer
supplied.
Note:
Ensure that all the wires are tucked into the blower
switch housing.
Switches
6.
Open the switch housing by removing the top screw.
7.
Install the thermodisc bracket as shown, using 2 of the
screws supplied. Connect the flagged leads to the
terminals of the thermodisc.
Remove the knock out from the housing label.
8.
Install the variable speed switch (rheostat) into the
housing with the wires facing up. Secure the switch to the
housing using the pal nut and the knob supplied.
9.
Connect the male connector on the switch to the female
connector coming from the unit.
10.
Pilot Indicator Light:
Install the batteries as shown.
Replace the batteries annually.
Note: If replacing the pilot
indicator light , ensure that the red wire lead connects
to the red lead of the thermopile and black to white.
11.
Tuck all of the wires into the housing and close. Secure
using the screw removed in step
6
.
This unit comes equiped with a pilot indicator
light that blinks every few seconds when the
pilot is on.
For more information see step #10.