Napoleon Arlington GDS20N Installation And Operation Instructions Manual Download Page 22

22

W415-0496 / B / 08.10.05

Contact your dealer for questions concerning prices and
availability of replacement parts. Normally all parts can
be ordered through your Napoleon dealer or distributor.
When ordering replacement parts always give the fol-
lowing information:

1.  M

ODEL

 & S

ERIAL

 N

UMBER

 

OF

 

FIREPLACE

2.  I

NSTALLATION

 

DATE

 

OF

 

FIREPLACE

3.  P

ART

 N

UMBER

4.  D

ESCRIPTION

 

OF

 

PART

5.  F

INISH

FOR

 

WARRANTY

 

REPLACEMENT

 

PARTS

A

 

PHOTOCOPY

 

OF

 

THE

ORIGINAL

 

INVOICE

 

WILL

 

BE

 

REQUIRED

 

TO

 

HONOUR

 

THE

 

CLAIM

.

REPLACEMENTS

IDENTIFIES

 

ITEMS

 

WHICH

 

ARE

 

NOT

 

ILLUSTRATED

FOR

FURTHER

 

INFORMATION

CONTACT

 

YOUR

 

NAPOLEON

 

DEALER

.

#

PART #

DESCRIPTION

1

W135-0248

LOG #1- REAR

2

W135-0249

LOG #2 - LEFT

3

W135-0250

LOG #3 - RIGHT

4

GL-651

LOG SET

5

W725-0035

SIT VALVE - NG

5

W725-0043

SIT VALVE - LP

6

W100-0084

BURNER (NATURAL GAS)

6

W100-0086

BURNER (PROPANE)

7

W455-0065

#45 BURNER ORIFICE - NG

7

W455-0050

#55 BURNER ORIFICE - LP

8

W010-0800

PILOT ASSEMBLY - NG

8

W010-0801

PILOT ASSEMBLY - LP

9

W455-0069

PILOT INJECTOR - NG

9

W455-0068

PILOT INJECTOR - LP

10

W680-0005

THERMOCOUPLE

11

W680-0004

THERMOPILE

12

W357-0001

PIEZO IGNITOR

13* W385-0245

NAPOLEON LOGO

14* W660-0009

ON/OFF SWITCH

15

W690-0002

THERMODISC

16

KB-35

VARIABLE SPEED SWITCH

17

GZ552

REPLACEMENT BLOWER

18

W135-0233

FRONT

19

W135-0232

SIDE (LEFT OR RIGHT)

20

W135-0231

TOP

21

W225-0162

DOOR

22

W010-1306

GLASS 

W

/ GASKET

23

W430-0013

CONTROL DOOR MAGNET

24

W010-1307

CONTROL COVER

25

W750-0149

PILOT LIGHT ASSEMBLY

26

W615-0072

FIRESTOP SPACER

27

W585-0198

FIRESTOP SPACER SHIELD

28 GD175  -  WALL TERMINAL KIT

29

BM6790

90°   ELBOW - 7" DIAMETER

30

GD222

TERMINAL ASSEMBLY

31

BM67ADJ

30" TO 53" ADJUSTABLE PIPE - 7" DIA

32

W500-0077

FIRESTOP / WALL PLATE

33

W020-0032

HARDWARE

34

BRTC7

BRASS TRIM COLLAR

35

BM6724

24" STOVE PIPE - 7" DIAMETER

36

W010-0300

10' ALUMINIUM FLEX LINER 

C

/

W

 

SPACERS

  - 4" DIA

37

W025-0001

DECORATIVE BRASS BAND

38 GD180  -  PERISCOPE TERMINAL KIT

29

BM6790

90°   ELBOW - 7" DIAMETER

39

GD201

PERISCOPE

31

BM67ADJ

30" TO 53" ADJUSTABLE PIPE - 7" DIA

32

W500-0077

FIRESTOP / WALL PLATE

33

W020-0032

HARDWARE

34

BRTC7

BRASS TRIM COLLAR

35

BM6724

24" STOVE PIPE - 7" DIAMETER

36

W010-0300

10' ALUMINIUM FLEX LINER 

C

/

W

 

SPACERS

  - 4" DIA

40 GD176  -  WALL TERMINAL KIT

34

BRTC7

BRASS TRIM COLLAR

35

BM6724

24" STOVE PIPE - 7" DIAMETER

37

W025-0001

DECORATIVE BRASS BAND

41

BM6745

45°  ELBOW

42

W410-0027

2 PLY FLEX ALUMINIUM LINER - 4" x 32.5"

GD110  -  1/12 TO 7/12 PITCH

43

W010-0569

AIR TERMINAL

44

W120-0036

VERTICAL CAP

45

W010-0567

ROOF SUPPORT

46

W170-0063

STORM COLLAR

47

W263-0054

ROOF FLASHING

GD111 - 8/12 TO 12/12 PITCH

43

W010-0569

AIR TERMINAL

44

W120-0036

VERTICAL CAP

45

W010-0567

ROOF SUPPORT

46

W170-0063

STORM COLLAR

47

W263-0055

ROOF FLASHING

GD112 - FLAT ROOF

43

W010-0569

AIR TERMINAL

44

W120-0036

VERTICAL CAP

45

W010-0567

ROOF SUPPORT

46

W170-0063

STORM COLLAR

47

W263-0056

ROOF FLASHING

48* W690-0001

MILLIVOLT THERMOSTAT

49* W690-0011B

REMOTE CONTROL - 

ADVANTAGE

 

PLUS

50

GS-65KT

BLOWER KIT

51* GDSLL-KT

LEG LEVELLING KIT

52* W175-0234

CONVERSION KIT - 

NG

-

LP

52* W175-0237

CONVERSION KIT - 

LP

-

NG

41

BM6745

45°  ELBOW

53

GD-301

HEAT GUARD

54* W175-0001

4" COUPLER

55

GD201

PERISCOPE

37

W025-0001

DECORATIVE BRASS BAND

56* GS331S

STOVE TOP INSET - SOAPSTONE

56* GS-331F

STOVE TOP INSET - GRANITE - 

GREEN

56* GS-331N

STOVE TOP INSET - GRANITE - 

BROWN

REPLACEMENT PARTS

TERMINAL KITS

ROOF TERMINAL KITS

ACCESSORIES:

Summary of Contents for Arlington GDS20N

Page 1: ...1 W415 0496 B 08 10 05 W415 0496 B 08 10 05...

Page 2: ...2 W415 0496 B 08 10 05 WHAT TO DO IF YOU SMELL GAS WARNINGS SAFETY PRECAUTIONS...

Page 3: ...nder water Immediately call a qualified service technician to inspect the stove and to replace any part of the control system and any gas control which has been under water Do not operate the stove wi...

Page 4: ...ot covered Any labour related to warranty repair is not covered Any labour related to warranty repair is not covered Any labour related to warranty repair is not covered CONDITIONS AND LIMITATIONS NAP...

Page 5: ...m with local codes In the absence of local codes install to the current standard for gas equipped mobile housing CAN CSA Z240 MH Series in Canada or the manufactured home construction and safety stand...

Page 6: ...in the centre of a building thereby allowing the most efficient use of the heat created The location of windows doors and the traffic flow in the room where the stove is to be located should be consid...

Page 7: ...bracket as shown using 2 of the screws supplied Connect the flagged leads to the terminals of the thermodisc Remove the knock out from the housing label 8 Install the variable speed switch rheostat in...

Page 8: ...n Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to unv...

Page 9: ...venting included WALL TERMINAL KIT GD176 24 of vent ing included or 1 12 TO 7 12 PITCH ROOF TERMINAL KIT GD110 8 12 TO 12 12 ROOF TERMINAL KIT GD111 FLAT ROOF TERMINAL KIT GD112 or STOVE PERISCOPE KI...

Page 10: ...bottom air slot is located a minimum of 12 inches above grade The maximum allow able vent length depends on the fireplace as illustrated FIGURES3a c FIGURE4 TYPICAL VENT INSTALLATIONS SPECIAL VENT IN...

Page 11: ...in feet feet inches 1 0 03 0 5 15 0 45 6 0 30 0 9 11 0 45 1 35 16 0 90 2 7 32 0 the first 45 and 90 offset has a zero value and is shown in the formula as 45 and 90 respectively or 135 when combined F...

Page 12: ...ET HT when HT VT Simple venting configuration only one 45 and 90 elbow Example 2 V1 4ft V2 1 5ft VT V1 V2 4 ft 1 5 ft 5 5 ft H1 2ft H2 1ft H3 1ft H4 1 5ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 one 45...

Page 13: ...ce both formulas are met this vent configuration is ac ceptable when HT VT FIGURE9 REQUIRED VERTICAL RISE IN FEET VT HORIZONTAL VENT RUN PLUS OFFSETS IN FEET HT FIGURE10 For vent configurations requir...

Page 14: ...eptable Formula 2 HT VT 40 feet 15 9 40 Since only formula 2 is met this vent configuration is unac ceptable and a new fireplace location or vent configuration will need to be established to satisfy b...

Page 15: ...in the ceiling and the roof to provide the minimum 1 inch clearance be tween the stove pipe and any combustible material Try to center the exhaust pipe location midway between two joist to prevent hav...

Page 16: ...ng Slide the storm collar around the air terminal and down to the caulking Tighten to ensure that a weather tight seal between the air terminal and the collar is achieved Attach the other storm collar...

Page 17: ...L copper tubing with a shut off valve to the stove 2 Seal and tighten the gas line securely to a flex connector DO NOT KINK FLEXIBLE CONNECTOR 3 Check for gas leaks by brushing on a soap and water so...

Page 18: ...It is not necessary to remove the cast front in order to remove the door 1 Lift the top cast piece off of the unit 2 Unlatch the door latches from the door 3 Slide the door straight up to remove Follo...

Page 19: ...shown onto the rear log support brackets Ensure the cutout on the left underside of the log fits over the pilot assembly Bend the bracket on the right side to help retain the rear log 2 Place the hol...

Page 20: ...itch must be in the ON position to ignite the burner 10 Turn on all electric power to the fireplace When lighting and re lighting the gas knob cannot be turned from PILOT to OFF unless the knob is dep...

Page 21: ...ermopile on one leg and reaches toward the burner on the other leg 5 Replace the cleaned logs 6 Check to see that the main burner ignites completely on all openings when the gas knob for the burner is...

Page 22: ...ER 30 GD222 TERMINALASSEMBLY 31 BM67ADJ 30 TO 53 ADJUSTABLE PIPE 7 DIA 32 W500 0077 FIRESTOP WALL PLATE 33 W020 0032 HARDWARE 34 BRTC7 BRASS TRIM COLLAR 35 BM6724 24 STOVE PIPE 7 DIAMETER 36 W010 0300...

Page 23: ...23 W415 0496 B 08 10 05 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Page 24: ...s knob is on HI wall switch thermostat is on Main burner orifice is plugged Faulty thermopile Faulty themostat or switch remove stoppage in orifice replace connect a jumper wire across the wall switch...

Page 25: ...led at all joints check that minimum rise per foot has been adhered to for any horizontal venting Air shutter has become blocked ensure air shutter opening is free of lint or other obstruc tions Flame...

Page 26: ...26 W415 0496 B 08 10 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Page 27: ...27 W415 0496 B 08 10 05 NOTES...

Page 28: ...28 W415 0496 B 08 10 05 NOTES...

Reviews: