Most natural gas systems and all LP gas systems have a service regulator located near the point where the
gas piping enters the building.
The propane tank will normally have an additional fi
rst stage regulator located at the tank outlet valve. All of
these regulators (located outdoors) will have a vent.
(Figure 2)
It is important for these vents to remain clear. Do not allow moisture, which could freeze, to build up in the vent.
If you see moisture building up in the regulator vent, contact your gas supplier.
FIGURE 2 - GAS REGULAT
OR VENT
Regulator vent
Keep free of ice, snow,
and debris
OBSTRUCTION OF THE AIR VENT ON
AN LP (PROP
ANE) CYLINDER OR TANK REGULA
TOR
CAN CAUSE EXPLOSION OR FIRE RESULTING IN PROPERTY
DAMAGE, SEVERE PERSON-
AL INJUR
Y OR DEA
TH.
YOUR GAS SUPPLIER SHOULD PERIODICALLY
INSPECT AND CLEAN THE
AIR VENT
SCREEN TO
PREVENT ANY
OBSTRUCTION. KEEP PROTECTIVE REGULA
TOR COVER IN
PLACE, AS EXPOSURE T
O THE ELEMENTS CAN CAUSE ICE BUILDUP
AND REGULA
TOR
FAILURE.
WARNING
!
!