NAPCO Security Systems
GEM-P1632 Installation Instructions
WI808B 8/98
Page 23
BA
SIC OPERA
T
ION
Arming with No Delay
Press the
button prior to or after arming.
This feature allows normal exit delay, but cancels the next entry delay through an entry/exit zone. The display red LED will
flicker. This feature may be used to provide instant protection while you or someone else is still on the premises. It will be
cancelled automatically upon disarming.
Priority Arming
A 2-second tone and “
” displayed when attempting to arm indicates a priority condition; that is, a
problem exists on at least one zone that has been designated a Priority Zone, or a system trouble exists. The trouble(s)
must be corrected before the panel can be armed. The display will read “
”, then automatically scroll through all
unsecured zones. If a system trouble is indicated, display the system trouble.
Area Arming/Manager’s Mode
In a partitioned system, either or both secured areas may be armed (or disarmed) from the Manager's Mode (if enabled).
The Manager's Mode, is a low-security mode of operation. It provides quick access to other areas without the system
status display.
To arm or disarm the alternate area:
1. Press the
or
button representing the alternate area.
2. Press the
button, then the
button. The keypad will display “
”, where “X” denotes the area
selected. In effect, you will now be in that area.
3. Arm or disarm the area using your code (the code must be valid in that area).
4. To return the keypad to its “home” area, the
button, then the
button.
Note: If the “home” keypad has been changed to the alternate area and unused for more than 5 minutes, it will revert to
the home area.