GEM-P1632 Installation Instructions
NAPCO Security Systems
WI808B 8/98
Page 26
KEYPA
D M
ESSA
GES
%
The GEM-RP1CAe2 Keypad can display the following messages. The GEM-RP2ASe2 will display similar abbreviated messages that
may scroll through two screens. Note: Refer to OI234 for the GEM-RP1CAe2 Keypad; OI192 for the GEM-RP2ASe2 Keypad.
SYSTEM READY CW - All zones operating; system can be
armed. GEM-RP1CAe2 only: C = Chime Mode on; W = Watch
Mode on; 1 through 2 = Area.
PLEASE WAIT - Panel reporting to central station on arming.
Wait for ringback signal to exit.
EXIT TIME XXX - Exit delay in progress. XXX = exit time
remaining in 10-second decrements; GEM-RP1CAe2 only: S =
Service Code active; I = arming with Instant protection.
ENTRY TIME XXX - Entry delay in progress. XXX = entry time
remaining in 10-second decrements.
SYSTEM ARMED - Panel armed. GEM-RP1CAe2 only.
ZONE FAULTS - One or more zones not secured. Display status
for zone description(s). GEM-RP1CAe2 only.
CAN'T ARM/ZONES NOT NORMAL - Arming attempted with
Priority Zone in trouble. Secure zone to arm.
DAY ZONE TRBL - Trouble condition on Day Zone, followed by
one or more zone descriptions.
INVALID ENTRY/TRY AGAIN - Wrong code/time/area number
entered.
CAN'T ARM SYSTEM/PRESS RESET - Arming attempted with
System Trouble present. Press the
button and then arm
the system.
ALARM - Alarm condition, followed by one or more zone descrip-
tions.
****FIRE**** - Fire alarm condition, followed by one or more zone
descriptions.
FIRE TROUBLE - Trouble condition on a Fire Zone. Press
button to silence the sounder. Correct the trouble, then
press the
button again.
FIRE ALARM - Alarm condition on a Fire Zone. Press the
button to silence the sounder. Correct the cause of the alarm,
then press the
button again.
ZONES BYPASSED - (When Zones Bypassed displayed) Indi-
cates zones that have been deactivated.
OV(R-) - Overview Mode (Status of 2 areas): R=Zone Ready;
also, Z=Zone Fault; A=Armed; B=Burglary Output; F=Fire Alarm;
T=Fire Trouble; C=Check Trouble; Display Mode.
SYSTEM TROUBLE - A System Trouble display will be followed
by one or more of the following error codes:
E01-00 - AC POWER FAIL. Power failure. Check power
transformer. Check for blown fuse or circuit breaker;
general power outage.
E02-00 - LOW BATTERY. Battery below 11 volts. If not
recharged within 24 hours, replace it.
E03-00 - COMM FAIL. Unsuccessful communication to
central station. Note: Will also display if panel improperly
programmed to report; i.e., Report Alarm, Report Codes,
Subscriber ID Numbers, etc. must be programmed.
E04-NN - WL TRBL. Wireless transmitter supervisory
failure. NN = transmitter number.
E05-NN - WL LOBATT. Rf transmitter low battery.
NN = transmitter number.
E06-NN - RF REC TROUBLE. Rf receiver response
trouble. NN = receiver number.
E07-00 - DOWNLOAD FAIL. Download failure.
E08-00 - TELCO LINE1 FAIL. Telephone line failure
(system trouble displays after a programmed delay).
E09-00 - NOT PROGRAMMED. System cold start.
E10-NN - BURG KEYPAD TRBL. Keypad response failure.
NN = keypad number.
E11-NN - BURG KPD TAMPER. Keypad cover removed.
NN = keypad number.
E12-NN - BURG EZM TRBL. Expansion zone module
failure. NN = module number.
E13-NN - BURG EZM TAMPER. EZM module cover re
moved. NN = module number.
E14-NN - RELAY BOARD TRBL. Relay board response
failure. NN = relay board number.
E15-NN - WL TAMPER. Transmitter cover removed.
NN = transmitter number.
E16-NN - RF REC JAMMED. Receiver jammed.
NN = receiver number.
E17-NN - RF REC TAMPER. Receiver cover removed.
NN = receiver number.
E18-NN - LOBATT KEYFOB. Key fob transmitter low
battery. NN = key fob transmitter number.
E19-00 - USER MEM ERROR. Internal memory error.
Select RESET SYSTEM TBL. Press the
button, then
the
button.
E20-00 - DEALER MEM ERROR. Same as above.
E22-NN - PIR SENSOR TRBL. No trip detected on PIR
Supervision Zone within programmed Sensor-Watch time.
NN = Zone number. To reset, press YES (
)
button at “
” function display.
E23-00 - BURG BUS FAILED. Failure of 4-wire bus. Check
Terminals 11/12.
E24-00 - TIME FOR SERVICE. A service message can be
programmed through the PCD3000 Quickloader
(event-schedule screen) to remind the user to arrange for
scheduled maintenance. At the programmed date and time,
the keypad sounder will start to pulse and the display will
read “
” (GEM-RP1CAe2) or “
”
(GEM-RP2ASe2). This condition will behave as a system
trouble and may be cleared as such, i.e., press the
button to silence sounder; access RESET SYSTEM TRBL,
then press the
button.
E39-00 - RF CAPACITY TRBL. Receiver capacity error.
E51-00 - Alarm Output Supervisory.
E99-00 - Keypad panic shorted too long. GEM-RP2ASe2
only.
NN OUT OF SYSTEM - Keypad inoperative. NN = keypad
number.
ALARM - (After panel is disarmed) displays zones violated.
FAULT FIND - Fault-find Mode activated.