background image

 

 GEM-P1632 Installation Instructions

 NAPCO Security Systems

WI808B 8/98

Page 36

NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrants
its products to be free from manufacturing defects in
materials and workmanship for 

thirty-six months

 following

the date of manufacture. NAPCO will, within said period,
at its option, repair or replace any product failing to oper-
ate correctly without charge to the original purchaser or
user.

This warranty shall not apply to any equipment, or any part
thereof, which has been repaired by others, improperly
installed, improperly used, abused, altered, damaged,
subjected to acts of God, or on which any serial numbers
have been altered, defaced or removed. Seller will not be
responsible for any dismantling or reinstallation charges.

THERE ARE NO WARRANTIES, EXPRESS OR IM-
PLIED, WHICH EXTEND BEYOND THE DESCRIPTION
ON THE FACE HEREOF. THERE IS NO EXPRESS OR
IMPLIED WARRANTY OF MERCHANTABILITY OR A
WARRANTY OF FITNESS FOR A PARTICULAR PUR-
POSE. ADDITIONALLY, THIS WARRANTY IS IN LIEU
OF ALL OTHER OBLIGATIONS OR LIABILITIES ON
THE PART OF NAPCO.

Any action for breach of warranty, including but not limited
to any implied warranty of merchantability, must be
brought within the six months following the end of the
warranty period.

IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE
FOR ANY CONSEQUENTIAL OR INCIDENTAL DAM-
AGES FOR BREACH OF THIS OR ANY OTHER WAR-
RANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS
OR DAMAGE IS CAUSED BY THE SELLER'S OWN
NEGLIGENCE OR FAULT.

In case of defect, contact the security professional who
installed and maintains your security system. In order to
exercise the warranty, the product must be returned by the
security professional, shipping costs prepaid and insured
to NAPCO. After repair or replacement, NAPCO assumes
the cost of returning products under warranty. NAPCO
shall have no obligation under this warranty, or otherwise,
if the product has been repaired by others, improperly
installed, improperly used, abused, altered, damaged,
subjected to accident, nuisance, flood, fire or acts of God,
or on which any serial numbers have been altered, de-
faced or removed. NAPCO will not be responsible for any
dismantling, reassembly or reinstallation charges.

This warranty contains the entire warranty. It is the sole
warranty and any prior agreements or representations,
whether oral or written, are either merged herein or are
expressly cancelled. NAPCO neither assumes, nor autho-
rizes any other person purporting to act on its behalf to
modify, to change, or to assume for it, any other warranty
or liability concerning its products.

In no event shall NAPCO be liable for an amount in excess
of NAPCO's original selling price of the product, for any
loss or damage, whether direct, indirect, incidental, conse-
quential, or otherwise arising out of any failure of the
product. Seller's warranty, as hereinabove set forth, shall
not be enlarged, diminished or affected by and no obliga-
tion or liability shall arise or grow out of Seller's rendering
of technical advice or service in connection with Buyer's
order of the goods furnished hereunder.

NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM
BE COMPLETELY TESTED WEEKLY.

Warning:  Despite frequent testing, and due to, but not
limited to, any or all of the following; criminal tampering,
electrical or communications disruption, it is possible for
the system to fail to perform as expected. NAPCO does
not represent that the product/system may not be compro-
mised or circumvented; or that the product or system will
prevent any personal injury or property loss by burglary,
robbery, fire or otherwise; nor that the product or system
will in all cases provide adequate warning or protection. A
properly installed and maintained alarm may only reduce
risk of burglary, robbery, fire or otherwise but it is not
insurance or a guarantee that these events will not occur.
CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY
FOR ANY PERSONAL INJURY, PROPERTY DAMAGE,
OR OTHER LOSS BASED ON A CLAIM THE PRODUCT
FAILED TO GIVE WARNING. Therefore, the installer
should in turn advise the consumer to take any and all
precautions for his or her safety including, but not limited
to, fleeing the premises and calling police or fire depart-
ment, in order to mitigate the possibilities of harm and/or
damage.

NAPCO is not an insurer of either the property or safety of
the user's family or employees, and limits its liability for
any loss or damage including incidental or consequential
damages to NAPCO's original selling price of the product
regardless of the cause of such loss or damage.

Some states do not allow limitations on how long an im-
plied warranty lasts or do not allow the exclusion or limita-
tion of incidental or consequential damages, or differenti-
ate in their treatment of limitations of liability for ordinary
or gross negligence, so the above limitations or exclu-
sions may not apply to you. This Warranty gives you spe-
cific legal rights and you may also have other rights which
vary from state to state.

NAPCO LIMITED WARRANTY

Summary of Contents for Gemini P1632

Page 1: ...WI808B 8 98 Napco 1998 R HARDWIRE WIRELESS...

Page 2: ...ity Systems Inc 333 Bayview Avenue Amityville New York 11701 For Sales and Repairs call toll free 800 645 9445 For direct line to Technical Service call toll free 800 645 9440 Internet http www napcos...

Page 3: ...17 KEYPAD CONFIGURATION MODE 18 Keypad Installation 18 Configuring the Keypads 18 BASIC OPERATION 21 User Codes Zone Descriptions 21 Arming and Disarming the System 22 Bypassing Zones 24 Alarm Indica...

Page 4: ...may be quickly and easily downloaded to the control panel using a PC compatible computer with Napco s PCD3000 Quickloader software and PCI2000 computer interface Or the panel may be programmed using...

Page 5: ...tary dial and TouchTone TM with Rotary backup Three 20 digit telephone numbers Backup Reporting Double Reporting Split Reporting 32 User Codes with Opening Closing Reporting by user AC Failure Reporti...

Page 6: ...IAL FIRE 16 5VAC TRANSFORMER BATTERY 12 VDC STANDBY CURRENT ALARM CURRENT STANDBY TIME 40VA 50VA 7 AH 120 mA 520 mA 1 24 Hours 40VA 50VA Two 7 AH 360 mA 280 mA 1 24 Hours 20VA 7 AH 120 mA 360 mA 1 24...

Page 7: ...78 Line Reversal Module PS3002 Power Supply Module 13 2Vdc 1 9A EOL2 2K End of Line Resistor Assy 2 2kW for Fire Circuit FT2200 End of Line Relay Resistor Supervisory Module RB1000 Relay Board RBATH1...

Page 8: ...anic connect only to UL listed holdup devices All zones must be programmed for Priority Do not program any zones for Keyswitch Arming System must be serviced at least once every 3 years Residential Fi...

Page 9: ...es for the machine screws it may be discarded after use Keypad A keypad should be located near each exit entry door The keypad features a handy pull up reference label Before mounting the keypad onto...

Page 10: ...tility room furnace room and hallways Heat detec tors rather than smoke detectors are recommended in kitchens attics and garages due to conditions that may result in false alarms and improper operatio...

Page 11: ...Range Wireless System The RM3008 may be used to interface the GEM P1632M control panel to the Ademco 7720 transmitter in order to meet UL Central Station Grade A or Grade B requirements by using a dig...

Page 12: ...transmitters proceed as follows Note Wireless systems have not been investigated by UL 1 Enter the Fault Find Mode 2 Fault a point of the transmitter to be tested by opening the loop If the signal st...

Page 13: ...e connected When connecting a mechanical bell it must be supervised using a 2 2k Ohm resistor To connect 8 Ohm Speakers use a Siren Driver with the proper polarity observed NOTE Refer to the GEM P1632...

Page 14: ...ted if the longest cable run from the panel to the farthest keypad daisy chained or home run is less than 1000 feet The maximum distance for seven keypads is 300 feet using 22 AWG wire NOTE When runni...

Page 15: ...the use of EZM Modules To do so simply select EZ Zone Doubling in programming refer to the GEM P1632 Programming Instructions and connect zones as shown above NOTE If both zones in a zone pair configu...

Page 16: ...ire smoke detectors are connected to zones 7 8 If Fire Alarm Verification is desired to reset the smoke detectors select this option for the desired fire zone zone 7 or 8 WIRING CONNECTIONS 4 WIRE SMO...

Page 17: ...nto an approved USOCRJ31X jack or a CA31A jack for Canadian installations The Telco Line is used by the control panel to dial the central station and for downloading This line should not be connected...

Page 18: ...er e EZM address and f zone response To enter the GEM RP1CAe2 Configuration Mode 1 Move jumper JP1 located at the upper right corner of the control panel board from Pins 1 2 top two to Pins 2 3 bottom...

Page 19: ...to continue or press the button to exit Zone Response The normal loop response of each keypad expansion zone is 750mS however the response time of any zone can be reduced to 50mS as follows 1 Of the f...

Page 20: ...ed that a GEM RP1CAe2 be selected as Keypad 1 Assign the keypad address number by selecting Jumpers J1 3 in accor dance with the table at left Note 1 Keypads are factory supplied with no jumpers insta...

Page 21: ...ay be programmed or it may be programmed as a two digit code for the purposes of quick arming Arm Only Code Programmable in Dealer Program Mode only An Arm Only Code may only be used to arm the area i...

Page 22: ...r disarm an Arm Only Code may only be used to arm Arming To arm enter a valid User Code then press the button If a wrong code is entered the keypad will display The green STATUS LED will go off the re...

Page 23: ...n be armed The display will read then automatically scroll through all unsecured zones If a system trouble is indicated display the system trouble Area Arming Manager s Mode In a partitioned system ei...

Page 24: ...forward or backward using the and the buttons respectively To return to normal keypad operation press the button The keypad will automatically return to its normal operating mode if no activity is de...

Page 25: ...nd a 2 second warning and the keypad will begin a 15 minute countdown with the sounder pulsing The sounder may be silenced by pressing the button but it will come back on one minute before arming With...

Page 26: ...Y Battery below 11 volts If not recharged within 24 hours replace it E03 00 COMM FAIL Unsuccessful communication to central station Note Will also display if panel improperly programmed to report i e...

Page 27: ...lighting disabled cut Jumpers W1 W2 W3 2 Backlighting disabled cut Jumpers A B C 3 Add 0 010A for each energized relay 4 Standby Time in Hours 1 STANDBY CURRENT X Amps AH STANDBY CURRENT Amps DEVICE Q...

Page 28: ...board be necessary use this wiring legend to relocate wire leads to their proper terminals Enter wire identification number or color code in WIRE NUMBER column and enter wire function in DESCRIPTION...

Page 29: ...RT FUNCTION MODE Keypad Commands NEXT YES PRIOR NO AREA Scroll Down Scroll Up Exit Yes No Press Bell Test Activated Chime Toggle On Off Exit Automatically No Yes Yes System to Arm in number of hours e...

Page 30: ...Bypassed Display Activated Bell Test Activated Chime Toggle On Off Exit Automatically Reset System Trouble Exit Automatically Activate Fault Find Download Activated Keypad Commands No No No No No No N...

Page 31: ...Zone Numbers in Area 1 Enter Entry Exit Zone Numbers in Area 1 Enter Central Station 1 Telephone Number No No Yes Yes Enter Number of Keypads in Area 1 Enter of Zones in Area 1 Press at any time Go to...

Page 32: ...er Program Option Enabled Bell Test Activated Chime Toggle On Off Exit Automatically No No Yes Yes System to Arm in number of hours entered w delay Exit Automatically Download Activated No No No Yes Y...

Page 33: ...1 ALARM CURRENT CAN BE INCREASED BY REDUCING STANDBY CURRENT BY THE SAME AMOUNT 2 THE FOLLOWING DEVICES MAY BE PLACE ON THE REMOTE BUS GEM RP1CAe2 GEM RP2ASe2 GEM EZM816 GEM X10 GEM RECV8 GEM RECV16...

Page 34: ...GEM P1632 Installation Instructions NAPCO Security Systems WI808B 8 98 Page 34 NOTES...

Page 35: ...ary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commissio...

Page 36: ...ssumes nor autho rizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liabl...

Reviews: