![Nanometrics RM-4 User Manual Download Page 32](http://html.mh-extra.com/html/nanometrics/rm-4/rm-4_user-manual_705058032.webp)
Internet
The “Internet” page (see Figure 12) displays the Internet configuration of the RM-4 and the
destinations to which it sends information via the network.
RM-4 Internet configuration
Communication port Defines the communication port used by the RM-4 system to send and
receive messages from the destination stations. Value ranges from 0 to
32768. Default value is 32000. Tech access.
IP address
Defines the IP address of the RM-4. For example, 129.3.14.3. Values range
from 0 to 255. Default value is 199.71.138.129. Tech access.
Gateway IP
Defines the IP address of the gateway. For example, 129.3.14.2. Values range
from 0 to 255. Default value is 0. Tech access.
Subnet mask
Network mask used to define the RM-4 subnet. For example, 255.255.255.0
Values range from 0 to 255 Default value is 255.255.255.0. Tech access.
Destination Internet configuration
A destination station is a remote computer to which the RM-4 server sends the time series data and
SOH information through an Internet connection. The RM-4 also listens for any request from the
remote computer, if the remote is running NAQSServer.
Port
The port used by the RM-4 to communicate with the destination computer.
Values range from 0 to 32768. Default value is 32000. Tech access.
IP address
The IP address of the destination computer. For example, 129.3.14.3. Use
0.0.0.0 to indicate not in use. Values range from 0 to 255. Default value is
0.0.0.0. Tech access.
Figure 12: Configuration of the Internet communications
RM-4 Manual 26
5 - User Interface
Summary of Contents for RM-4
Page 1: ...RM 4 Bridge Multiplexer Manual ...
Page 2: ......
Page 3: ...RM 4 Bridge Multiplexer User Manual ...
Page 8: ...This page intentionally left blank ...
Page 10: ...This page intentionally left blank ...
Page 12: ...This page intentionally left blank ...
Page 40: ...This page intentionally left blank ...