46
8B. SERVICES – To be conducted by a technician only –
8B-2-1 General
Problem
Main cause
Remedy
Page
The machine will not turn
on.
The power cord is disconnected.
Connect the cord securely to the
AC outlet.
The fuse is blown.
Replace the fuse.
The game will not start.
(The attraction is not
displayed.)
The connectors on the MAIN PCB
are disconnected.
Connect them securely.
Page 55
MAIN PCB failure
Replace the PCB.
Page 55
The machine
malfunctions or operation
is unstable.
The power supply voltage is
outside the range of 104 to 127 V
AC
Disconnect large power
consuming equipment (air
conditioners, large rides, etc.)
from the same power line, and
ensure that the game machine
receives the specified power
supply voltage.
8B-2-2 Middle Box assembly
Problem
Main cause
Remedy
Page
No images on the LCD
monitor
The connectors to the LCD
monitor are disconnected.
Connect them securely.
Page 54
LCD monitor failure
Replace the LCD monitor.
Page 52
MAIN PCB failure
Replace the PCB.
Page 55
8B-2-3 Under Box assembly
Problem
Main cause
Remedy
Page
No sound from the
loudspeakers
The sound volume is set to the
minimum.
Turn the volume up.
Page 29
The connectors to the
loudspeakers are disconnected.
Connect them securely.
AMP PCB failure
Replace the PCB.
Page 59
MAIN PCB failure
Replace the PCB.
Page 55
To Purchase This Item, Visit BMI Gaming | www.bmigaming.com | (800) 746-2255 | +1.561.391.7200