SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
Nailor Industries Inc. reserves the right to change any information concerning product or pricing without notice.
14" (356)
6"
(152)
1/2"
(13)
H
15 1/2" (394)
5 1/2"
(140)
AIRFLOW
CONTROLS ENCLOSURE
FOR FACTORY
MOUNTED CONTROLS
INLET: ROUND,
FLAT OVAL OR
RECTANGULAR
MULTI-POINT
AVERAGING
FLOW SENSOR
OPTIONAL
ACCESS DOOR
11" (279)
W
SLIP AND DRIVE
CONNECTION
DAMPER
DRIVESHAFT
6"
(152)
1/2"
(13)
H
11" (279)
W
DATE
B SERIES
SUPERSEDES DRAWING NO.
3 - 30 - 17
3000
10 - 28 - 16
D3001-2
Page 1 of 2.
Dimensions are in inches (mm).
SINGLE DUCT TERMINAL UNIT
DIGITAL OR ANALOG CONTROLS • PRESSURE
INDEPENDENT • CONSTANT OR VARIABLE VOLUME
MODELS: D3001 AND A3001 WITH BOTTOM MOUNT
CONTROLS LOCATION (OPTION OB)
Standard Features:
• Bottom mount controls location with
vertical drive shaft (option code OB).
• 22 ga. (0.86) zinc coated steel casing,
mechanically sealed, low leakage
construction. Leakage is less than 1% of
nominal flow at 1" w.g. (250 Pa).
•
16 ga. (1.61) corrosion-resistant
steel inclined single blade damper with
extruded PVC seals (single blade on size
4, 5, 6). 45° rotation, CW to close. Tight
close-off. Damper leakage is less than
2% of the terminal rated airflow at 3" w.g.
(750 Pa).
• 1/2" (13) dia. plated steel drive shaft.
An indicator mark on the end of the shaft
shows damper position.
• Multi-point averaging Diamond Flow
Sensor. Aluminum construction. Supplied
with balancing tees.
• Rectangular discharge with slip and
drive cleat duct connection.
• Full NEMA 1 type controls enclosure for
factory mounted controls.
• 3/4" (19), dual density insulation,
exposed edges coated to prevent air
erosion. Meets the requirements of
NFPA 90A and UL 181.
Controls:
q
Digital (by others).
q
Analog (by Nailor).
See separate submittal.
Options and Accessories:
q
Steri-liner.
q
Fiber-free liner.
q
Solid metal liner.
q
1" (25) liner.
q
Side access door.
q
24 VAC Control transformer.
q
Toggle disconnect switch.
q
Hanger brackets.
q
Controls enclosure for field mounted
controls.
q
Dust tight enclosure seal.
q
Special Features: _____________ .
*
Maximum airflow limit is based upon 1.5" w.g. (373 Pa) max. differential pressure signal from Diamond Flow Sensor.
Dimensional Data
Unit
Size
Airflow Range*
cfm (I/s)
W
H
Inlet Size
4
0 – 225 (0 – 106)
10 (254)
10 (254)
3 7/8 (98) Round
5
0 – 400 (0 – 189)
10 (254)
10 (254)
4 7/8 (124) Round
6
0 – 550 (0 – 260)
10 (254)
10 (254)
5 7/8 (149) Round
7
0 – 800 (0 – 378)
12 (305)
12 1/2 (318)
6 7/8 (175) Round
8
0 – 1100 (0 – 519)
12 (305)
12 1/2 (318)
7 7/8 (200) Round
9
0 – 1400 (0 – 661)
14 (356)
12 1/2 (318)
8 7/8 (225) Round
10
0 – 1840 (0 – 868)
14 (356)
12 1/2 (318)
9 7/8 (251) Round
12
0 – 2500 (0 – 1180)
18 (457)
12 1/2 (318) 12 15/16 x 9 13/16 (329 x 249) Oval
14
0 – 3125 (0 – 1475)
24 (610)
12 1/2 (318)
16 1/16 x 9 13/16 (408 x 249) Oval
16
0 – 3725 (0 – 1758)
28 (711)
12 1/2 (318)
19 3/16 x 9 13/16 (487 x 249) Oval
24 x 16
0 – 8330 (0 – 3931)
38 (965)
18 (457)
23 7/8 x 15 7/8 (606 x 403) Rect.