SINGLE DUCT TERMINAL UNIT WITH
ELECTRIC REHEAT
DIGITAL OR ANALOG CONTROLS
PRESSURE INDEPENDENT
MODELS: D30RE AND A30RE
DATE
B SERIES
SUPERSEDES DRAWING NO.
6 - 17 - 20
3000
5 - 15 - 19
D30RE-1
Standard Features:
• 22 ga. (0.86) zinc coated steel casing,
mechanically sealed, low leakage
construction.
• 16 ga. (1.63) corrosion-resistant steel
inclined opposed blade damper with
extruded PVC seals (single blade on size
4, 5, 6). 45
°
rotation, CW to close. Tight
close-off. Damper leakage is less than 2%
of the terminal rated airflow at 3" w.g. (750
Pa).
• 1/2" (13) dia. plated steel drive shaft.
An indicator mark on the end of the shaft
shows damper position.
• Multi-point averaging Diamond Flow
Sensor. Aluminum construction. Supplied
with balancing tees.
• Rectangular discharge with slip and
drive cleat duct connection.
• Full NEMA 1 type low voltage controls
enclosure for factory mounted controls.
•
3/4" (19), dual density insulation,
exposed edges coated to prevent air
erosion. Meets the requirements of NFPA
90A and UL 181.
• Electric Coil is mounted in an integral
plenum section.
• 24 VAC Control transformer.
• Right-hand controls location is standard
(shown) when looking in direction of
airflow. Optional left hand controls
mounting is available.
Controls:
q
Nailor EZvav.
q
Factory mount (by others).
See separate submittal.
Options and Accessories:
q
Steri-liner.
q
Fiber-free liner.
q
Solid metal liner.
q
Perforated Metal Liner.
q
1" (25) liner.
q
Bottom access door.
q
Hanger brackets.
q
Controls enclosure
for field mounted
controls.
q
Dust tight enclosure seal.
q
20 ga. (1.00) construction.
Seismic Certification:
q
SSI (Standard).
q
OSHPD.
q
Special Features: ______________ .
Electric Coil Features, Options and
Accessories:
See page 2 of 2.
*
Maximum airflow limit is based upon 1.5" w.g. (373 Pa) max. differential pressure signal from Diamond Flow Sensor.
Dimensional Data
Unit
Size
Min.– Max. Airflow Range*
cfm (I/s)
W
H
Inlet
Size
4
25 – 225 (12 – 106)
10 (254)
10 (254)
3 7/8 (98) Round
5
45 – 400 (21 – 189)
10 (254)
10 (254)
4 7/8 (124) Round
6
65 – 550 (31 – 260)
10 (254)
10 (254)
5 7/8 (149) Round
7
95 – 800 (45 – 378)
12 (305)
12 1/2 (318)
6 7/8 (175) Round
8
125 – 1100 (59 – 519)
12 (305)
12 1/2 (318)
7 7/8 (200) Round
9
165 – 1400 (78 – 661)
14 (356)
12 1/2 (318)
8 7/8 (225) Round
10
215 – 1840 (101 – 868)
14 (356)
12 1/2 (318)
9 7/8 (251) Round
12
290 – 2500 (137 – 1180)
18 (457)
12 1/2 (318)
12 15/16 x 9 13/16 (329 x 249) Oval
14
360 – 3125 (170 – 1475)
24 (610)
12 1/2 (318)
16 1/16 x 9 13/16 (408 x 249) Oval
16
430 – 3725 (203 – 1758)
28 (711)
12 1/2 (318)
19 3/16 x 9 13/16 (487 x 249) Oval
24 x 16
960 – 8330 (453 – 3931)
38 (965)
18 (457)
23 7/8 x 15 7/8 (606 x 403) Rect.
Listed
*
Minimum flows are based
upon 0.02" w.g. differential
pressure from flow sensor. The
maximum flow rate represents
the diamond flow sensor’s
differential pressure reading at
1” w.g. (250 Pa).
AIRFLOW
5 1/2"
(140)
29" (737)
31" (787)
W
6"
(152)
H
1/2" (13)
OPTIONAL ACCESS DOOR
W
6"
(152)
11"
(279)
1/2"
(13)
H
CONTROLS ENCLOSURE
FOR FACTORY
MOUNTED CONTROLS
INLET: ROUND,
FLAT OVAL OR
RECTANGULAR
MULTI-POINT
AVERAGING
FLOW SENSOR
PRIMARY
AIR
VALVE
CONTROLS
ENCLOSURE
SLIP AND DRIVE
CONNECTION
ELECTRIC COIL
CONTROLS
ENCLOSURE
(HINGED ACCESS
DOOR)