background image

Page 10

Instruction manual 5900110x 

Version 1 July-08

Thank you for choosing this equipment. We sincerely wish that you enjoy your Nahita

high vacuum pump. We highly recommend looking after this equipment according to
what is stated in this manual.

Nahita develops its products according to the CE marking regulations as well as

emphasizing the ergonomics and security for its user. 

The correct using of the equipment and its good quality will permit you to enjoy this

equipment for years.

The improper use of the equipment can cause accidents and electric discharges, circuit

breakers, fires, damages, etc. Please read the point of Maintenance, where we expose the
security notes.

TO GET THE BEST RESULTS AND A HIGHER DURATION OF THE EQUIP-

MENT IT IS ADVISABLE TO READ THOROUGHLY THIS MANUAL BEFORE
OPERATING WITH THE EQUIPMENT.

Please bear in mind the following:
This manual is inseparable from the Nahita high vacuum pump, so it should be availa-

ble for all the users of this equipment.

You should carefully handle the equipment avoiding sudden movements, knocks, free

fall of heavy / sharp objects on it. Avoid spilling liquids inside the equipment.

Never dismantle the different pieces of the equipment to repair it yourself, since it could

produce a defective use of the whole equipment and a loss of the product warranty, as
well as injuries on people that handle the oscillating stirrer.

To prevent fire or electric discharges avoid dry or dusty environments. In case it may

happen unplug the equipment immediately. 

If you have any doubt about setting up, installation or functioning do not hesitate in

contacting your wholesaler. You can also tell us any doubts or suggestions you have by
contacting Nahita Technical Assistance Department by email to [email protected] or
by telephone: +34 807 117 040 (0.30 Euros/min).

This equipment is protected under the Warranties and consumer goods regulation

(10/2003).

Overhaul is not covered by the equipment warranty.
Operations made by non-qualified staff will automatically produce a loss of the

warranty.

Neither fuses nor accessories (including their loss), are covered by the product’s

warranty. The warranty neither covers piece’s deterioration due to the course of time.

Please make sure you keep the invoice, either for having the right to claim or asking for

warranty coverage. In case you have to send the equipment to Nahita Technical Assistance
Department you should enclose the original invoice or a copy as guarantee.

Please do not forget filling the warranty certificate and send it before 15 days after the

date of purchase.

Manufacturer reserves the right to modify or improve the manual or equipment.




Revision 1 Juillet-08

Manual d’usage 5900110x 

Page 19

ATTENTION ! AUCUN APPAREIL NE SERA RÉPARÉ S’IL N’A PAS

PRÉALABLEMENT ÉTÉ CORRECTEMENT NETTOYÉ ET DÉSINFECTÉ.

INDEX OF LANGUAGES

Espagnol

Anglais

Français

2-9

10-17

18-26

1. APPLICATIONS DE L’APPAREIL

2. DESCRIPTION

3. SPÉCIFICATIONS TECHNIQUES

4. INSTALLATION / MISE EN MARCHE

5. MAINTENANCE ET NETTOYAGE

6. RÉSOLUTION DES PROBLÈMES
ANNEXE I: CERTIFICAT CE

19

19

20

20

23

24

27

INDEX OF CONTENTS

1. APPLICATIONS DE L’APPAREIL

Ces pompes à haut vide sont utilisées dans laboratoires et industrie chimie, emballage

sous vide, réfrigération, équipements de lyophilisation, lampes, métallisées, imprégnation
par vide, etc…  

2. DESCRIPTION

1.1. Poigné pour son transport
1.2. Interrupteur allumé/éteint
1.3. Bouche de charge d´huile
1.4. Viseur du niveau d´huile
1.5. Bouchon  de drainage d´huile
1.6. Valvule d´entrée de gaz
1.7. Valvule de connexion au vide
1.8. Couvercles de protection 

ENGLISH

FRANÇAIS

Summary of Contents for 55001102

Page 1: ...s prestaciones y una mayor duración del mismo This manual should be available for all users of these equipments To get the best results and a higher duration of this equipment it is advisable to read carefully this manual and follow the processes of use Nous vous recommandons lire attentivement cet manuel d instructions et suivre tous les procédures d usage à fin d obtenir les meilleures preesta t...

Page 2: ...así como la pérdida de los mismos no están cubiertos por dicha garantía Tampoco estarán cubiertos por el periodo de garantía las piezas en su des gaste por uso natural Asegúrese de guardar la factura de compra para tener derecho de reclamación o pres tación de la garantía En caso de enviar el equipo al Servicio Técnico adjunte factura o copia de la misma como documento de garantía Rellene y envíe ...

Page 3: ...réutilisation d appareils vieux vous étiez faisant une contribution important à la protection de l environnement S il vous plaît il faut faire le contact avec l administration de votre communauté pour demander les points de recyclage Revisión 1 Julio 08 Manual de instrucciones 5900110x Pág 3 ATENCIÓN NO SE ADMITIRÁ NINGÚN APARATO PARA REPARAR QUE NO ESTÉ DEBIDAMENTE LIMPIO Y DESINFECTADO 1 APLICAC...

Page 4: ... embalaje 1 6 1 7 1 8 Revision 1 Juillet 08 Manual d usage 5900110x Page 25 3 La pompe démarre mais a une haute consommation électrique ampérage CAUSE SOLUTION L huile est très épaisse haute viscosité Changement d huile pour une autre o la température ambiance est plus moins visqueuse basse que 5ºC La pompe est surchargée avec huile Corriger le niveau d huile enlevant l excès Corps étranges dans l...

Page 5: ... No aceptaremos ningún equipo en periodo de devolución sin que vaya en su emba laje original Instalación Antes de comenzar a utilizar el instrumento es conveniente familiarizarse con sus com ponentes y fundamentos básicos así como con las funciones de sus controles LEA DETALLADAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE OPERAR CON ESTE EQUIPO CON EL FIN DE OBTENER LAS MÁXIMAS PRES TACIONES Y UNA ...

Page 6: ...pe sur une table horizontale stable en créant un espace libre d au moins 30 cm de chaque côté Ne placez pas l appareil dans des zones proches à des sources de chaleur Bec bunsen chalumeau N exposez pas l appareil directement au soleil et évitez les vibrations et la poussière Pendant le fonctionnement aucun matériel dangereux tels que les liquides inflamma bles ou le matériel pathologique ne devron...

Page 7: ...una superficie horizontal plana y estable donde las vibraciones producidas no afecten a equipos cercanos La parte trasera de la bomba debe estar perfectamente ventilada y libre de obstrucciones No coloque la bomba de alto vacío en zonas próximas a fuentes de calor mecheros sopletes ni exponga el equipo directamente a la luz del sol Evite las vibraciones el polvo y los ambientes muy secos Durante s...

Page 8: ...e garantie Nous n accepterons pas aucun appareil en période de restitution sans son emballage original Installation Avant de commencer à utiliser l appareil il est important de se familiariser avec ses composants ses fondements basiques et ses fonctions Par mesure de sécurité nous vous conseillons de réviser l appareil avant son utilisation LISEZ ATTENTIVEMENT CE MANUEL D INSTRUCTIONS AVANT D UTIL...

Page 9: ...de la bomba paletas rotas Servicio Técnico Nahita rodamientos dañados ó trabados Baja tensión en la alimentación eléctrica Verificar la tensión 5 La bomba en funcionamiento tiene temperatura elevada CAUSA SOLUCIÓN Gases aspirados a altas temperaturas Verificar el proceso Analizar la posibilidad de colocar un enfriador No hay suficiente aceite ó el aceite Incrementar el nivel del aceite si no es el...

Page 10: ...cting Nahita Technical Assistance Department by email to asistencia auxilab es or by telephone 34 807 117 040 0 30 Euros min This equipment is protected under the Warranties and consumer goods regulation 10 2003 Overhaul is not covered by the equipment warranty Operations made by non qualified staff will automatically produce a loss of the warranty Neither fuses nor accessories including their los...

Page 11: ...uvez consulter distributeur installation mise en marche fonc tionnement etc Vous pouvez également nous envoyer vôtres doutes ou suggestions au Service Technique Nahita par e mail à asistencia auxilab com ou par téléphone au 0034 807117040 0 30 Euros min Cet appareil est sous la protection de la Loi des Garanties et des Biens de Consommation 10 2003 Révisions de l appareil ne sont pas en garantie L...

Page 12: ...uction manual 5900110x Page 17 5 The pump presents is too hot when operating CAUSE SOLUTION Gases sucked at high temperatures Verify the process Study the possibility of using a cooling system There is no enough oil or it is too Correct the level of oil If it is contaminated contaminated drain it and add new oil Cleaning Never use scourers or substances that can grate for cleaning metallic parts s...

Page 13: ...riginal wrapping Installation Before using the vacuum pump it is convenient for you to familiarize with its compo nents and basic essentials as well as with its control functions PLEASE READ THOROUGHLY THE INSTRUCTIONS BEFORE CONNECTING AND OPERATING WITH THIS EQUIPMENT WITH THE AIM OF ACHIEVING THE HIGHEST FEATURES AND THE MAXIMUM DURABILITY OF THE INS TRUMENT Put the pump on top of a horizontal ...

Page 14: ...g the pump for a long period of time please make sure it is unplugged in order to avoid possible accidents It is essential to have the equipment switched off and unplugged from the net before cleaning checking components or replacing any piece Never try to repair the pump by yourself since you will lose the warranty and may pro voke damages to the general operating system or the electrical install...