background image

8 / 24

Mesurement Method

The display of a menu function is displayed as follows.

Whenever it presses the [MENU] key, an item changes.

(Example of a display)

A U T O

O F F

F F

O

W E L D

M E T H O D

A C

R A N G E

L o

I M P U L S E

0

U N I T

c y c

S T A R T

C Y

5

.

0

E N D

9 9 . 5 C Y

S A V E

M O D E

O V E R

C L E A R

M E M .

C L E A R

C N T .

F R E Q U E N C Y

H z

0

6

Summary of Contents for MDM22-M01A

Page 1: ...Handy Nadescorder MDM22 M01A Instruction Manual ...

Page 2: ...he caution with this mark may result in injuries or physical damage This mark indicates that improper handling may create shock hazards This mark indicates that improper handling may lead to troubles caused by poisonous substance This mark indicates that improper handling may cause injury or other troubles This mark indicates that improper handling may create fire hazards This mark indicates that ...

Page 3: ...ak or fire When disconnecting a cord or cable be sure to do so by holding the plug or connector Otherwise the cord or cable may have a break which will eventually develop into functional failure overheating or fire 2 Be sure to use the charging AC adapter supplied with the equipment Use of another AC adapter may not only lead to failure of the equipment but also cause fire or explosion due to abno...

Page 4: ...ation it may generate heat ignite or explode 7 Please do not put in a battery pack into fire If it puts in into fire or heats it may explode or explode 8 Changes or modifications not expressly approved by the manufacturer for compliance could void the user s authority to operate the equipment 9 In order to comply with FCC radio friquency radiation exposure guidelines for an uncontrolled exposure t...

Page 5: ... a long period of disuse store the equipment with the charging AC adapter and other appendent units disconnected from it 3 Never engage in disassembly remodeling or unwarranted adjustment of this equipment Tinkering with this equipment may cause equipment failure or malfunction 4 Do not use a volatile fluid such as benzene or thinner when wiping the equipment clean Use of such a fluid can cause th...

Page 6: ...stal display 7 4 3 Notes on the Use of CT Coil 9 4 4 Note on the Use of Tip Voltage Detection Cable 10 5 Selection of Menu Function 11 5 1 How to select 11 5 2 Selection Menu Items 11 6 Communication Method 16 6 1 In the Case of USB 16 6 2 In the case of radio communications Bluetooth 16 7 How to Charge 18 8 Error Display 19 9 Troubleshooting 20 10 Specification 22 ...

Page 7: ...ttery is built in it is cordless and can be used 5 Collection of the data in remoteness is possible by radio communications Bluetooth 6 The connectors for the cables used are all easy to use one touch connectors 7 There are two measuring ranges namely Lo 2 50 to 19 99kA and 10 00 to 49 99kA You can select a range best suited to the current levels you are going to measure 8 The WELD lamp lights up ...

Page 8: ...mes and Functions of Components Names and Functions of Components Names and Functions of Components Names and Functions of Components 2 Names and Functions of Components 5 6 1 2 3 4 7 8 9 10 11 CHARGE WELD Handy Nadescorder POWER SEL MENU DISP ...

Page 9: ...hange of menu item The lighting for LCD turns on at the time of a measured value display 5 The connector for current measurement Connect the appendant CT cable 6 The connector of voltage between tips Connect the appendant tip voltage cable 7 Liquid crystal display Measured value is displayed in measurement mode The contents of a menu are displayed in menu mode 8 WELD lamp Lights up when welding is...

Page 10: ...s Bluetooth or USB PDA PC C H A R G E C H A R G E C H A R G E C H A R G E W E L D W E L D W E L D W E L D Handy Nadescorder POWER S E L S E L S E L S E L M E N U M E N U M E N U M E N U D I S P D I S P D I S P D I S P Handy Nadescorder CT Tip voltage detection cable welding machine ...

Page 11: ... 5 When you measure the tips voltage please connect the tip voltage detection cable Notes on measurement If you connect the connector with the power on the trigger may work and a measurement will be made But the data from this measurement are invalid Be sure therefore to turn off power before connecting or disconnecting the connector Since it will be regarded as a weld end if it becomes 50 of peak...

Page 12: ...also connect CT cable simultaneously When you connect the tip voltage detection cable please do not connect AC adapter and a USB cable It cannot measure correctly When it becomes an unusual welding form in AC measurement it cannot measure correctly Measurement data may be unable to be saved when a measurement interval is very short Tip voltage of AC inverter welding machine cannot be measured In D...

Page 13: ...DISP key Whenever it presses the DISP key switching display of weld time weld current tip voltage weld counter and remain of memory Example of a display The following is displayed when ms is chosen weld current weld time cyc voltage between tips weld counter remainder of memory R E M A I N M 1 0 0 0 0 1 5 0 C Y 1 1 5 0 k A V 2 1 0 W C O U N T 3 weld current weld time ms 0 m s 5 2 1 1 5 0 k A ...

Page 14: ...ws Whenever it presses the MENU key an item changes Example of a display A U T O O F F F F O W E L D M E T H O D A C R A N G E L o I M P U L S E 0 U N I T c y c S T A R T C Y 5 0 E N D 9 9 5 C Y S A V E M O D E O V E R C L E A R M E M C L E A R C N T F R E Q U E N C Y H z 0 6 ...

Page 15: ...t correct values can be obtained when measured in this position Please fix to secondary conductor so that CT does not move during measurement In case you attach CT please insert the tip of CT firmly to the back of a case Danger Use extreme caution not to hurt your hand when hooking up the CT coil to the gun for the welding machine secondary conductor ...

Page 16: ...duction by the tip voltage detection cable when measuring the tip voltage as shown in the following figure please make connection of the tip voltage detection cable When especially a lead is made to gather and is attached induced electromotive force becomes small and the tip voltage can measure correctly Tip voltage detection cable CT coil ...

Page 17: ...e 5 2 Selection Menu Items 1 Selection of welding method There are two welding methods to select from namely AC welding DC welding AC When measurement is made with a single phase AC welder DC When measurement is made with inverter controlled welder and AC inverter controlled welder Example of a display Caution The tip voltage of AC inverter welding machine cannot be measured 2 Selection of frequen...

Page 18: ...regarded as an impulse by 1 or more cycle pause and it is regarded as the welding end by 31 or more cycle pause At the time of msec measurement it is regarded as an impulse by 13 or more msec pause and it is regarded as the welding end by 101 or more ms pause If impulse No is set as 2 in the case of the following figure the 2nd step of welding will be measured When there is no 31 or more cycles we...

Page 19: ...can measure 6 Setting of measurement start cycle A measurement start cycle is set up cyc It can set up in the range of 0 5 9 5 cyc ms It can set up in the range for 1 199ms at the time of DC welding Example of a display When the up slope etc is included in welding current control steady state current can be measured by specifying a measurement start cycle In the case of a figure a measurement star...

Page 20: ...measurement end cycle is set as 10 0cyc 8 Setting of the data save method The data saved is Average data 10000 data Each cycle msec data 20 data Wave data 1 newest data OVER The newest welding point in the range of the number of the maximum storage is saved LOCK It is not saved after storage and it to the number of the maximum storage Example of a display Caution Waveform data this setup is invali...

Page 21: ...urrently recorded is eliminated Display 1 When SEL key is pressed it displays as follows 2 Press SEL key and the data will be cleared Press MENU key and it cancels carrying out 11 Erase of measurement data It chooses whether the measurement data currently recorded on the memory is eliminated Display 1 When SEL key is pressed it displays as follows 2 Press SEL key and the data will be cleared Press...

Page 22: ...escription of software about the communicative method Caution Please do not perform USB communication and radio communications Bluetooth simultaneously Data is not compensated when it connects simultaneously The communication distance in radio communications Bluetooth is less than 10m However it may become short according to a surrounding electric wave situation an obstacle and installation enviro...

Page 23: ... the manufacture line of a factory besides industry science and medical apparatus such as a microwave oven etc are employed 1 Please check in near that the premises radio station and specific power saving for move object discernment are not employed before using this product 2 When the example of electric wave interference occurs from this product to the premisesradiostationformoveobjectdiscernmen...

Page 24: ...dling enough Moreover covering paper and cloth during charge should stop Please be sure to charge in a cool place with sufficient ventilation It may become the cause of a fire Even if it connects AC adapter for charge when a CHARGE lamp does not light up the defect of a battery pack is considered Please stop use immediately Caution Current cannot be measured when it is displayed on a liquid crysta...

Page 25: ...is not able to measure by other items When it is not able to measure by other items When it is not able to measure by other items When welding time of 100 cycles or 2000msec or more cycles is carried out When a setup of measurement time is wrong When larger current than a measurement range is measured When larger voltage than the measurement range is measured When a setting value is not reached V ...

Page 26: ...t is displayed as kA It is a current overflow error Please check a measurement range If it is Lo range please make a setting change at Hi range If it is Hi range it is outside the specification range It is displayed as CY or ms It is an impulse setting error Please input the suitable value for which the number of setting impulses is not suitable It is displayed as CY or ms It is a cycle setting er...

Page 27: ...s V It is a measurement impossible error 1 Cycle overflow 2 current value overflow 3 current value under flow 4 cycle setting error 5 impulse setting error Has not error generated An error should not occur It is displayed as Memory Error Setting data and measurement data are destroyed Please push any keys A LCD display will be the initial screen Data Initialize 0 0CY 0 00kA A memory is reset compu...

Page 28: ...welding The effective value of each cycle 6 Measurement of welding range Welding current Lo 2 50 19 99kA Resolution 0 1kA Hi 10 00 49 99kA Resolution 0 2kA Weldingtime 0 5 to 99 5 cycle Resolution 0 5 cycles 1 1999ms Resolution 1ms Tip voltage 0 00 5 00V Resolution 0 01 V Tip resistance 1 2000 micro ohm Resolution 1 micro ohm 7 Measurement accuracy Welding current 2 FS Tip voltage 5 FS Tip resista...

Page 29: ...data 1 data Preservation by the Comma Separated Value is possible at PC edit is possible at Excel etc 14 External Output Radio communications Bluetooth USB 15 Power Supply Built in rechargeable battery Li ion 780mAh 16 Charge Time About 5 hours 17 Operation time Continuation 8 hours 18 Power Consumption Duringstanding 63 mA During wireless communication 115 mA 19 Overall dimensions 58 h x155 w x22...

Page 30: ... C H A R G E C H A R G E C H A R G E C H A R G E W E L D W E L D W E L D W E L D Handy Nadescorder POWER S E L S E L S E L S E L M E N U M E N U M E N U M E N U D I S P D I S P D I S P D I S P 146 58 22 155 Outside figure ...

Page 31: ... Jun 11 2004 Up Date Drawing No 102806 311 0 Press NADEX Co Ltd NISHIHARU FACTORY 1 OMIYAMAE TOKUSHIGE NISHIHARU CHO NISHIKASUGAI GUN AICHI PREF 481 0038 JAPAN PHONE 81 568 21 1428 FACSIMILE 81 568 23 5540 ...

Page 32: ......

Reviews: