13 / 24
Selection of Menu Function
(5) Selection of measuring range
There are two measuring range to select from, namely, Lo and Hi .
Lo
: 2.50kA to 19.99kA
Hi
: 10.00kA to 49.99kA
(Example of a display)
Caution
- If average data is measurement within the limits even if the current value of
each cycle is outside the measurement range, it can measure.
(6) Setting of measurement start cycle
A measurement start cycle is set up.
cyc: It can set up in the range of 0.5 - 9.5 cyc.
ms : It can set up in the range for 1 - 199ms. (at the time of DC welding)
(Example of a display)
When the up slope etc. is included in welding current control, steady-state current can be measured
by specifying a measurement start cycle. In the case of a figure, a measurement start cycle is set as
2.5cyc.
R A N G E
L o
S T A R T
C Y
5
.
2
Steady-state current
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
0.5
Summary of Contents for MDM22-M01A