background image

 

Page 

1

 of 

22

 

 

 

 

TASER Axon Mic  

User Manual

Model AX1004

 

IMPORTANT SAFETY INSTRUCTIONS

 

Read all warnings and instructions.  Save these 
instructions.

 

The most up-to-date warnings and instructions are 
available at www.TASER.com 

MMU00## Rev: X1 

 

Summary of Contents for Axon Mic AX1004

Page 1: ...SER Axon Mic User Manual Model AX1004 IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions Save these instructions The most up to date warnings and instructions are available at www TASER com MMU00 Rev X1 ...

Page 2: ...icrophone 10 EVENT Mode Starting Recording 11 Adding Markers to Recorded Audio 11 Battery Status 12 Configuring Your Axon Mic 12 Adjusting the Audio Prompt Volume 12 Turning off the Microphone LEDs Stealth Mode 12 Other Settings 13 Chapter 4 Notification Reference Tables 14 Audio Prompts 14 LED Status 14 Operation LED 14 Function LED 14 Battery LED 15 Upload Status LED 15 Chapter 5 Axon Signal Ope...

Page 3: ...Page 3 of 22 Chapter 7 Troubleshooting 19 Customer Service 19 Warranty Policy 19 Warnings 19 Radio Waves 19 Declaration of Conformity 21 ...

Page 4: ... Information Read understand and follow all warnings and instructions before using this product The most up to date warnings and instructions are available at www taser com Additional Reading This manual explains how to operate the Axon Mic hardware Other manuals cover additional aspects of the Axon Mic and Axon Fleet system These documents are available at www taser com The Axon Academy website e...

Page 5: ...erating mode for Battery status see the battery LED described below Operating Mode Operation LED Recording Recovering interrupted video Blinking Red Buffering Blinking Green Booting up powering down Error state Solid Red When the Function LED also is blinking red When the Function LED also is solid red Function LED Function LED Operation LED upload status LED On off switch Function button on off i...

Page 6: ...o start hold for 4 seconds to stop recording The Mic might take several additional seconds to close out of the video when it is powered off before stopping an event Battery Status Button When pressed the Battery button lights up the Battery LED which momentarily indicates the remaining battery capacity only it does not indicate the operating mode Battery LED When lit momentarily indicates the rema...

Page 7: ...Dock has no communication with the device Contact TASER customer service LED off Pressing buttons causes the Axon Mic to emit audio alerts beeps to indicate system actions See Chapter 4 Notification Reference Tables for more information Accessories The Axon Mic is designed to work with the new Axon RapidLock mounting system The RapidLock mounting system consists of the attachment piece called the ...

Page 8: ...se steps 1 Insert the key on the back of the Axon Mic into the lock 2 Twist the RapidLock mount counterclockwise 90 degrees 3 Place the magnetic back underneath the shirt patrol vest or whatever you are using 4 Hold the back in place and place the RapidLock mount over the back Magnetic attraction will hold the microphone in place 1 2 ...

Page 9: ...Page 9 of 22 ...

Page 10: ...turing anything unless the agency has configured audio in buffer ON and will not record to permanent memory while in BUFFERING mode When configured at the agency level to be ON buffered audio duration is 30 seconds by default 00 00 30 When you activate the EVENT mode the buffered audio if this feature is enabled at the agency level captured directly before the event up to 30 seconds will be saved ...

Page 11: ...es if the system is paired to a GPS capable smart phone will be recorded This will continue throughout the duration of the recording until you terminate the recording The Axon Mic provides you with indications that it is recording in EVENT mode At the start of an event and every 2 minutes during an event the system will beep twice The Operation LED on top of the device will blink red 2 To stop rec...

Page 12: ...esired volume settings for the audio beeps recorded by the device The volume has 4 settings At each level the Axon Mic beeps providing you with a sample of the volume Low Medium High Off Turning off the Microphone LEDs Stealth Mode For some situations you may wish to turn off the lights on your Mic You can turn off the lights through the Evidence Sync software or by using the Battery button To tur...

Page 13: ...ttery level For interpreting the LED colors see Chapter 2 Getting to Know Your Axon Mic To turn the lights back on 1 Connect the Axon Mic to the Evidence Sync application 2 Select the device settings 3 Select the option to turn on the device LEDs Other Settings Your organization s administrator can further configure your Axon Mic with these features Pre event buffer of up to 2 minutes Axon Signal ...

Page 14: ...ng Two beeps None The device is ending an event and re turning to BUFFERING mode One long beep Once long duration The battery is at 20 percent capacity or lower Four quick beeps every 5 minutes Four times quickly every 5 minutes The device s memory is full Three beeps The device will not start recording Three times LED Status Operation LED Operating Mode Operation LED Recording Recovering interrup...

Page 15: ... System Status LED Indication Initial connection momentary Solid red for 20 seconds or fewer In queue awaiting upload Solid yellow Device ready all files uploaded successfully and fully charged Solid green Device not assigned agency mismatch or device error Blinking red Uploading data Blinking yellow Firmware update internal battery charging extremely low battery or memory full Blinking red and ye...

Page 16: ...a signal to your Axon devices Upon processing this signal your Axon devices transition from BUFFERING to EVENT mode When your device starts recording you will hear two beeps The ASU has a range of approximately 30 feet 9 1 meters Another vehicle s light bar activation may cause your Axon devices to start recording if the light bar is equipped to do so The ASU can only send a signal to tell the dev...

Page 17: ...utes This message indicates that less than approximately 20 percent of the battery capacity remains Always recharge a depleted battery as soon as reasonably possible You can use an Axon Dock wall charger or computer to charge the battery Using a non TASER approved wall charger may degrade device performance and will void the warranty If the Axon Mic is to be stored for a long time the Battery LED ...

Page 18: ...Page 18 of 22 3 Remove the back of the device 4 Put the new device back in place with the device front 5 Using a Torx T6 screwdriver fasten the screws into the new device back Do not over tighten ...

Page 19: ...to radio frequency RF energy set by the Federal Communications Commission FCC of the U S Government These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies The standards incl...

Page 20: ...put power of this wireless device is far below the FCC radio frequency exposure limits This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RSS 210 Warning Statement The installer of thi...

Page 21: ...e so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication Conformément à la réglementation d Industrie Canada le présent émetteur radio ne peut fonctionner qu au moyen d une antenne d un seul type et d un gain maximal ou inférieur approuvé pour l émetteur par Industrie Canada Dans le but de réduire les risques de brouillage ra...

Page 22: ...rademark of Acumen Global Technologies and Windows is a trademark of Microsoft Corporation AXON Axon Axon Dock Axon Fleet Axon RapidLock Axon Signal Axon View Evidence com Evidence Sync TASER and are trademarks of TASER International Inc some of which are registered in the US and other countries For more information visit www taser com legal All rights reserved 2016 TASER International Inc MMU00 R...

Reviews: