233969 / 01/13 (A20)
9
Machine Set-Up
AlWAyS ENSURE tHAt tHE bAttERy IS dISCONNECtEd
bEFORE MAKING ANy AdJUStMENtS
!
!
Fitting the brushes
Featuring the Nulock brush system.
The brush is simply pushed and twisted to lock, making fitting and removal a simple process.
Slide the brush / pad under the brush deck (Fig 6).
Fit the brush / pad onto the Nulock drive chuck, twist to lock
the brush / pad in place (Fig 7).
Only use manufacturer supplied brushes.
This machine requires a 16 inch brush or a 16 inch pad.
Fitting the Floor tool
The floor tool has been designed for quick fitting, allowing easy squeegee blade replacement and a safety knock-off
feature if the floor tool gets snagged, whilst in transit.
Swing the floor-tool carrier to the side of the machine
(Fig 8).
Secure to the carrier using the
two knobs fitted to the floor-tool
carrier (Fig 9) - (Fig 9a).
Do not over tighten the retaining
knobs.
Fig 6
Fig 7
Fig 8
Fig 9
Fig 9a
Safety gloves are recommended for the changing of used brushes.
Note:
It is easier to fit the floor-tool if the weight of the machine is
resting on the brush. Ensure the brush is fitted first.