Input Settings
Parameter
Terminal
Range
Default
Sequential Input
Takes on activation to open then another to close door
Input 62
Terminal 4 Open Slow
Exterior
Activation
Causes slow opening of the door
Safety with Lockout
Swing side header mounted sensor input
Continuous Safety
Swing side door mounted sensor input
Reduced Opening
Causes unit to change to reduced open
Emergency Close
Forces the door to slowly close and lock (if equipped)
Hold Open Mode
Causes the door to hold open forever
Input 62
Open Timer
N/A
Same as Open Timer,
0 thru 10, 12,15, 20,25 sec
Same as
Open timer
Hold open time for Input 62
Input H Setting
Terminal
10
— —
— —
No input
All Activation Mode
Activates in all modes but OFF
Interior Activation
Activation on interior for One Way mode
Exterior Activation
Activation on exterior
Beam Sensor
Beam input
LE Approach Sensor
LE door mounted sensor
Unlock Input
Receives unlocked signal from elec Lock
Spring Close Only
Turns off power close and hold close
Sequential Input
Takes on activation to open then another to close door
Open Slow
Causes slow opening of the door
Safety with Lockout
Swing side header mounted sensor input
Continuous Safety
Swing side door mounted sensor input
Reduced Opening
Causes unit to change to reduced open
Emergency Close
Forces the door to slowly close and lock (if equipped)
Hold Open Mode
Causes the door to hold open forever
Input H
Open Timer
N/A
Same as Open Timer,
0 thru 10, 12,15, 20,25 sec
Same as
Open timer
Open Timer Setting for this Terminal only
Input 61 Circuit
N/A
X
Normally Open
X
Normally Close
Normally
Open
Circuit logic for Input 61
Input 62 Circuit
N/A
X
Normally Open
X
Normally Close
Normally
Open
Circuit logic for Input 62
Input 6B Circuit
N/A
X
Normally Open
X
Normally Close
Normally
Open
Circuit logic for Input 6B
Input
SWL Circuit
N/A
X
Normally Open
X
Normally Close
Normally
Open
Circuit logic for Input SWL
Insert BA Circuit
N/A
X
Normally Open
X
Normally Close
Normally
Closed
Circuit logic for Input SWL
6B Stop Closing
N/A
X
Yes
No
Determines door movement stop or close, when 6B is
ON at latch check while closing cycle.
X
No
After 6B Open?
N/A
X
Yes
Yes
Determines door movement open or close, after 6B.
X
No
61 Monitoring
N/A
X
Active
X
Not Active
Not Active
Sensor monitoring function *
62 Monitoring
N/A
X
Active
X
Not Active
Not Active
Sensor monitoring function *
6B Monitoring
N/A
X
Active
X
Not Active
Not Active
Sensor monitoring function *
SWL Monitoring
N/A
X
Active
X
Not Active
Not Active
Sensor monitoring function *
* If Monitoring is enabled for any input then the sensor MUST be connected to Output 1 or 2.
Output 1 or 2 must then be programmed to “Sensor Health Check”. If an error occurs, the door will
hold open until the error clears or the power is cycled.