10 of 32
Opus Control Wiring and Programming Installation Manual
www.NabcoEntrances.com
P/N C-00139
Rev 10-20-17
Base Settings
Setting Category
Menu Item
Default
Action
Door Hand
(for Fold Doors)
X
Left
X
Right
Left
From the Exterior Side of Building, determine which Handing to
enter: Left or Right
DN 0833
EXTERIOR BREAKOUT SIDE
LEFT HAND
RIGHT HAND
Door Hand
(for Slide Doors)
X
Left
X
Right
Left
From the Exterior Side of Building, determine which Handing to
enter: Left or Right
RIGHT HANDING
DN 1326
LEFT HANDING
EXTERIOR SIDE OF BUILDING
Operator Type
X
GT-300/400/500 Swing
X
GT-1175 Slide
X
GT-710 Swing
GT-710
Swing
X
Select Operator Type
X
If installing a GT-1400 Fold Door, select GT300/400/500 Swing
Reduced Stroke
X
Yes
X
No
No
X
Reduced opening manually move door and push YES
Movement Settings
Parameter
Range
Default
Description
Open Speed
0 - 7
3
The higher the number the faster the Door opens
Back Check Speed
0 - 7
3
Sets door speed during Back Check
Back Check Range
0 - 7
3
X
Swing Door: 2-1/2° to 35° of Fully Open
X
Slide Door: 1" to 13-3/4" of Fully Open
Close Speed
0 - 7
3
The higher the number the faster the Door closes
Latch Check Speed
0 - 7
3
Sets door speed during latch check
Latch Check Range
0 - 7
3
X
Swing Door: 10° to 45° of Fully Closed
X
Slide Door: 1" to 13-3/4" of Fully Closed
Open Timer
0-10, 12, 15, 20, 25, 30
2
Amount of Hold Open time after deactivation in seconds
Reaction Power
0 - 7
3
Determines how fast the door reacts to a reactivation when closing
Open Recycle Sens
0 - 7
3
Determines how hard the door will push against an obstruction
during opening
Close Recycle Sens
0 - 7
3
X
Determines how hard the door will push against an obstruction
during closing.
X
Close Recycle is disabled when “No Power Close” and Close
Recycle Sensitivity “7” is selected.
After Open Recycle
Slow Open, Stop
Slow Open Determines what happens after a recycle during Opening cycle.
Close Recycle
Reopen
Yes
Yes
Determines what happens after a recycle while closing cycle.
No
Optional Settings
Parameter
Range
Default
Description
Hold Close Force
0 - 3
0
0
OFF
3
Strongest Hold Close force
Sim Pair Setting
Single Door
Single
Door
Select type of Door
Normal Sim Pair
If selected; before returning to last screen, option to copy
settings to other Control is given.