19 of 32
www.NabcoEntrances.com
OpusControlWiringandProgrammingInstallationManual
Rev. 10-20-17
P/N C-00139
SECTION 11.2: Activation using ON/OFF/Hold-Open Switch
DN 1330
1
12VDC +12VDC
2
GND
Common for 12V and Signals
3
61
Interior Ac va on
4
62
Exterior Ac va on/Programmable Input
5
6B
Swing Door Con nuous Safety (door mounted, swing side Safety Sensor)
Slide Door
Holding Beam
6
SWL
Swing Door Safety with Lockout (overhead, swing side safety sensor)
Slide Door
Sidelite Sensor
7
Out1 Programmable Output
14
13
12
11
10
9
8
7
6
5
4
3
2
1
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Exterior Push-Plate
Interior Push-Plate
COM
N.O.
COM
N.O.
All Devices Must Be
N.O. Dry Contact
Powered Activation Devices
(sensor, card reader, radio receiver, etc.)
Powered Activation Devices
Non-Powered Activation Devices
WARNING!
Total Power Consumption Of All Sensors And Powered Activation
Devices Must Not Exceed 750 mA
All Device Outputs Must Be
N.O. Dry Contact
COM N.O.
PWR+ PWR-
COM N.O.
PWR+ PWR-
Exterior Activation
Interior Activation
RADIO
RECEIVER
7
6
5
4
3
2
1
3
2
4
RED
BLUE
BLACK
14
13
12
11
10
9
8
8
WHITE
Off
Hold Open
On
Off
7
6
5
4
3
2
1
3
2
4
1
RED
BLUE
BLACK
14
13
12
11
10
9
8
8
WHITE
Off
Hold Open
On
Off
NOTE:
If not using ON/OFF/HOLD OPEN switch,
change "Input BA Circuit" to "Normally Open