6-18
Wiring Safety Devices
Magnum 4A Control Wiring and Adjustment Manual
Part #C-00084
Rev. 9-09-16
The Panic Latch Switch is used to prevent activation when the door is broken out in a normally closed
circuit (when safety is fail-safe). When the door is broken out, the Panic Breakout Limit Switch will OPEN
the circuit to activate the Continuous Safety feature and disable the Operator.
1.►
Turn OFF Power.
2.►Go to Panic Latch located at bottom of Header.
3.►Ensure that the EXT
⇢
arrow points to the
Exterior
side of the building. Panic Breakout Limit
Switch will OPEN when door is broken out. Please see Figure 6-1
DN 0644
EXT
INTERIOR SIDE
EXTERIOR SIDE
Figure 6-5
Normally Closed Arrow points to Interior
4.►Go to Dip Switch (2). Flip switch OFF.
5.►Go to ends of each (Red) wire connected to Panic Latch Harness. Cut white plastic connectors off.
Please see
6.►Strip all wire ends 1/4 inch.
7.►Insert Red wires into Pole 3 (Continuous Safety) and into Pole 5 (Common). Please see Figure 6-6
.
Figure 6-6
Panic Latch
w/Safety Sensors
(Fail Safe)
DN 0570
BROW
N
BLAC
K
RE
D
WHIT
E
VIOL
ET
ORANGE
2
3
4
5
6
1
2
3
5
6
To Magnum Control
Safety with Lockout
during door swing
To Terminal #5
Normally Closed Contacts
Continuous Safety
Normally Closed Contacts
Red
Red
Part # 11- 0941
Panic Latch Kit
TERMINAL BLOCK
#1 BROWN
#2 ORANGE
#3 VIOLET
#4 WHITE
#5 RED
#6 BLACK
24VAC NEUTRAL
24VAC HOT
CONTINUOUS SAFETY
SAFETY WITH LOCKOUT
ACTIVATION
When using normally closed safety, all panic breakout devices connected to
continuous safety must be wired in series. If sensor contacts
or a panic latch opens, the door can not activate.
BROW
N
BLAC
K
RE
D
WHIT
E
VIOL
ET
ORANGE
2
3
4
5
6
1
2
3
4
To Magnum Control
Safety with Lockout
To Terminal #5
Normally Closed Contacts
Continuous Safety
Normally Closed Contacts
Red
Red
Red
Red
SIMULTANEOUS PAIRS
SINGLE DOORS
Panic Latch must be positioned so that
arrow marked
"EXT" points to exterior
of building.
(Contacts must open when door is broken out)
Panic Latch must be positioned so that
arrow marked
“EXT” points to exterior
of building.
(Contacts must open when door is broken out)
Safety with Lockout
(Overhead Sensors)
Normally Closed Contacts
On double egress doors
using two overhead safety
sensors with normally closed
safety, outputs of both
sensors must be wired in
series.
(Overhead Sensor)(
Door Mounted Sensor)
Continuous Safety
Normally Closed Contacts
(Door Mounted Sensor)
To Terminals
4 and 5
COMMON