GT300-350-8300-8350OpusOverheadConcealedSwingDoorInstallationManual
Rev 5-23-18
P/N C-00175
3. Insert the Weather Strip into both channels located on the Finger Guard Mounting Plate.
a. Spraying silicone (not included) inside the Channels may ease the insertion of the Weather Strip.
Figure 25 Install Weather Strip onto Finger Guard Mounting Plate
DN 0470
Weather Strip
Channels
Weather Strip
Channels
Finger Guard Moun ng Plate
SIDE VIEW
Assembled Finger Guard
4. Line up the Center Notch located down the full length of the Finger Guard Mounting Plate, with the Center Mark located on
the Pivot Jamb Tube. It is recommended to use a level.
Figure 26 Secure Weatherstrip Extrusion to Hinge Jamb Tube
DN 0471
Hinge Jamb Tube
Weatherstrip Extrusion
Center Line
Plumb Line
1/8” Screw Hole
1/8 x 1” Self Tapping
Steel or Zinc Plated Screw
5. Drill (3-4) 1/4 inch evenly spaced screw holes down the Finger Guard Assembly.
a. Each screw hole must go through the Weather Strip, Mounting Plate and the Pivot Jamb Tube.
6. Secure the Finger Guard Mounting Plate onto the Pivot Jamb with 1/4 x 1 inch self tapping Screws (zinc or steel plated).
CHAPTER 7: 120 VAC GENERAL WIRING
Shut the installation site branch Circuit Breaker OFF. Failure to do so may result in serious
personal or fatal injury. When uncertain whether power supply is disconnected, always
verify using a voltmeter.
All high voltage electrical connections must be made by licensed electricians according to
National and Local electrical codes/regulations.
Permanent wiring shall be employed as required by local codes.
Electrical circuit to Nabco operator must not be not shared with other equipment such
as lighting, cash registers, or any device that might cause electrical interference on the
circuit.
Keep sufficient spacing between high-voltage and low-voltage wiring. 120 VAC Power
wires must be routed (separate from other wiring) located near the top of inside Header.
Ensure that incomming electrical ground is properly secured to the grounding screw or
grounding wire, whichever is provided.
Attention: Insert all Incoming 120 VAC Power wires into the pre drilled Electric Service Access Hole located at
the left or right side of Header End Cap .
Note: It is recommended for the Installer to house all Incoming 120 VAC wires within an Electrical Conduit.
WARNING
WARNING
CAUTION
CAUTION
CAUTION
CAUTION