20 of 32
Swing and Fold Door Opus Control Wiring and Programming Installation Manual
www.NabcoEntrances.com
P/N C-00139
Rev 8-11-21
SECTION 11.2: Motor Wiring
11.2.1 GT8300/8400/8500
DN 1315
ENCODER MOTOR WIRING
NONENCODER WIRING
Handing Harness
(Right Hand Units)
To Opus Control
To Motor
To Motor
Non-Encoder
Adapter Harness
To Opus Control
Motor
Harness
To Door
Posi on Switches
Brake Module
2 11
2
2
1
12
2
1
1 2
2 11
2
2
1
12
11.2.2 GT710/8710
DN 1327
ENCODER MOTOR WIRING
NONENCODER WIRING
Non-Encoder Adapter Harness
To Motor
To Motor
To Opus Control
2
1
1
2
To Door Posi on
Switches
Motor Harness
2
1
1
2
Motor Fuse
To Opus Control
Motor Harness
Motor Fuse
SECTION 11.3: Other
DN 1333
EXAMPLE OF A
PROGRAMMABLE INPUT
I/O Terminal 8 - 14
8
BA Breakout
Used mainly for sliding door, can be used for ON/OFF with Swing
Doors.
9
SQ Sequen al Ac -
va on
Signal to Open, signal to Close.
10
H
Programmable Input
11 M0 Mode 0
When grounded, puts door into ONE WAY Mode.
When grounded with M1, puts door into HOLD OPEN Mode.
12 M1 Mode 1
When grounded, puts door into NIGHT Mode.
When grounded with M0, puts door into HOLD OPEN Mode
13 Out2 Aux. Output 2
Programmable output, closes to GND
14 GND Ground
Common for all above signals.
Example: A Switch being used to turn
ON/OFF Power Close and Hold Close.
Programmable Terminal 10, (Input H)
would be set to DISABLE POWER CLOSE.
5
1
2
34
67
12
89
10
11
13
14
CAN Bus Communica on:
Used to connect Sim Pair, Astragal,
Sequencing and the NET-HT Cable
when programming.
12
8
910
11
13
14
10
14