32
Table 23
Entering to
FAN menu
you can set the parameters according to
Table 23
as
below:
Temp.On
set’s the fumes temperature that the fan starts.
Temp.Off
set’s the fumes temperature that the fan stops.
Level 1- 5
set’s the fan speed at minimum (level 1) and at the
maximum (level 5). Do not reduce the values beyond the table
settings.
4.3.5.5 – PELLET FEEDER MENU
Table 24
Entering to
Pellet Feeder menu
you can set the parameters according to
Table 24
as below:
Duration at Min
set’s the time on duration of the pellet feeder motor
at the minimum power (level 1)
Duration at Max
set’s the time on duration of the pellet feeder moter
at the maximum power (level 5)
MENU
SUB MENU
SUB
VALUE
SETTINGS
Technical
Menu
Fan Menu
Number of Fans
0-1-2
0
Temp.On Fan
0 - 200
°
C
50-65
°
C
Temp.Off Fan
0 -200
°
C
85
°
C
Level 1 Fan 1
1 - 40
15-35
Level 5 Fan 1
1 - 40
25-35
Level 1 Fan 2
1 - 40
N/A
Level 5 Fan 2
1 - 40
N/A
MENU
SUB MENU
SUB
VALUE
SETTINGS
Technical
Menu
Pellet Feeder
Pellet Feeder Brake
On
Off
Off
Duration at Min Power
0,0 -7,5 s
1,5-3,5
Duration at Max Power
0,0 - 7,5 s
3,0 – 7,0
AUX output
On
Off
Off