36
4.3.5.9 -
IGNITION MENU
Table 29
Entering to
Ignition Menu
you can set the parameters according to
Table 29
as below
:
Fumes Temp. ON
sets the fumes temp. that should be reached in
order to change the state to Fire On.
Fumes Temp. OFF
sets the fume temp. during shutdown in order to
finish the shutdown state. The temp. cannot be sated less than 5
degrees from the Fumes On Temp.
Pre-Startup Duration 1
sets the time in seconds for the warm up of
the igniter (resistance).
Pre-Startup Duration 2
sets the time in seconds for the first filling of
the burner pot in order to achieve the ignition.
Warm Pre-Duration
as above.
Ignition Duration
sets the total time in seconds to achieve the
ignition. If that time passes and there is no flame or the Fumes Temp.
on is not reached than appears A01 alarm.
Fire On Duration
sets the time in seconds for the final stage of the
ignition. The purpose of that time is to burn the extra pellet in the pot
that is stocked during the ignition so it will go normally and not full of
MENU
SUB MENU
SUB
VALUE
SETTINGS
Technical
Menu
Ignition Menu
Fumes Temp. ON
0-150
°
C
50-65
°
C
Fumes Temp. OFF
10 -290
°
C
45-60
°
C
Pre-Startup Duration 1
0-300s
30-120s
Pre-Startup Duration 2
0-300s
Variable
Warm Pre-Startup
0-300s
Ignition Duration
0-3600s
600-900
Fire On Duration
0-400s
Variable
Thermocouple
On
OFF
Off