33
All between levels are automatically calibrate.
Step of the duration is 0.05s so never increase or decrease the time
by making big changes unless you are 100% sure for the setting.
Pellet feeder duration time changes also by the Recipe Menu (see
par. SETTINGS) so every time you intervene this menu check your
settings at MENU > SETTINGS > RECIPE > PELLET POWER.
4.3.5.6 -
COMBUSTION AIRFLOW MENU
Table 25
Entering to
Combustion Air Flow menu
you can set the parameters according
to
Table 25
as below
:
Air Flow control
engages or disengages the Air Flow sensor. By default the
selection accords to if the stove/boiler is equipped or not with the sensor.
In case of malfunction of the sensor you can put it in OFF.
RPM control
engages or disengages the RPM sensor of the extractor fan.
Air Flow at Min Power
set’s the required flow (liters per minute) of the
combustion air at the minimum power (level 1).
Air Flow at Max Power
set’s the required flow (liters per minute) of the
combustion air at the maximum power (level 5).
Technical
Menu
Combustion
Air Flow
Air Flow control
On
Off
Off
RPM control
On
Off
Off
Low rpm Limiter
On
Οff
Off
RPM at Min Power
0 - 2.750 rpm
500 -2500
RPM at Max Power
0 - 2.750 rpm
350-2750
Motor Type
0 - 100
Variable
MENU
SUB MENU
SUB
VALUE
SETTINGS