Glossary
Manual No. 771971
Glossary-9
During the automatic rebuild process, system activity continues as normal.
System performance may degrade slightly during the rebuild process.
To use the standby rebuild feature, you should always maintain a standby
SCSI disk in your system. When a disk fails, the standby disk will
automatically replace the failed drive and the data will be rebuilt. The system
administrator can disconnect and remove the bad disk and replace it with a
new disk. The administrator can then make this new disk a standby.
The standby replacement table has a limit of 8 automatic replacements in
any session (from power-on/reset to the next power-off/reset). When the
limit of 8 is reached and a disk failure occurs, the standby replacement will
occur but will not be recorded in the replacement table.
To clear the ‘standby replacement’ table, reboot the system from a DOS
bootable floppy, run the configuration utility and select the option ‘view/
update configuration’ from the main menu. A red box labeled ‘Drive Remap
List’ will be displayed. Selecting the box will allow you to continue. You
should save the configuration without making any changes, and exit the
configuration utility. This will clear the replacement table. You may now
proceed to boot your system and continue normal operations.
In normal use, the replacement table limit of 8 should not cause any
problems. Assuming that a disk fails about once a year (drives we support
generally come with a 5-year warranty), the system would run continuously
for a minimum of 8 years before the table would need to be cleared.
Stripe Order
The order in which SCSI disk drives appear within a drive group. This order
must be maintained, and is critical to the controller’s ability to ‘Rebuild’
failed drives.
Stripe Size
The stripe size is defined as the size, in kilobytes (1024 bytes) of a single I/O
operation. A stripe of data (data residing in actual physical disk sectors,
which are logically ordered first to last) is divided over all disks in the drive
group.
Summary of Contents for DAC960PG
Page 1: ...PCI RAID Controller Installation Guide DAC960PG PCI to Ultra SCSI P N 771971 D01...
Page 2: ......
Page 10: ......
Page 24: ...DAC960PG Specifications 1 10 DAC960PG Installation Guide...
Page 35: ...Functional Description Manual No 771971 2 11 Figure 2 4 Configuration on Disk Flowchart...
Page 48: ...Cache Management 2 24 DAC960PG Installation Guide...
Page 76: ...System Reboot or Power Down 4 10 DAC960PG Installation Guide...
Page 78: ...SAF TE A 2 DAC960PG Installation Guide...
Page 90: ...Battery Backup Capacity B 12 DAC960PG Installation Guide...
Page 102: ...Glossary Glossary 12 DAC960PG Installation Guide...
Page 105: ......
Page 106: ......