MYLAPS BibTag Timing system V.30. ENG. November 2020
© MYLAPS rights reserved 54
ID
Error
Problems
Solutions
332 Battery fuse broken
Battery fuse is faulty
Replace fuse
316 Battery temperature
too high to charge
Battery temperature too high
Charge battery in correct temp. range
314 Battery temperature
too low to charge
Battery temperature too low
Charge battery in correct temp. range
600 CCNet error
Contact MYLAPS
Connection to the CCNet server is
lost
Wait for BibTag to reconnect. If error
occurs frequently, check GSM status
or network connections
604 CCNet Unregistered
Register device
Device is unregistered
Register the BibTag at the CCNet
server - refer to
http://partner.mylaps.com for more
information
602 CCNet Auth failed
Login OK?
Internet unavailable
Check APN, User name and password.
Contact network provider
CCNet not found
Server settings OK?
Internet unavailable
Check APN, User name and password.
Contact network provider
328 Charge error
high current
The measured charge current is too
high
The measured charge current is too
high
326 Charge error
low current
The measured charge current is too
low
Connect alternative (110 - 240 VAC)
supply. Contact MYLAPS if error
repeats
102 Chip queue at 75%
save passings
Memory is becoming full
Save the current passings to Timing &
Scoring
104 Chip queue at 90%
save passings
Memory is becoming full
Save the current passings to Timing &
Scoring
106 Credit time > 75%
Credit time is running out
Sync to Tag Use Server
108 Credit time expired
Credit time has run out
Sync to Tag Use Server
400 Communication error
Contact MYLAPS
Undefined
Contact MYLAPS
500 Decoder error
Contact MYLAPS
Internal communication failed
Contact MYLAPS