3.7.1 PVC BRACKETS FOR TOOTHED RACK B117
a) Identify closing and opening brackets according to the
motor position against the gate (Fig. 12).
b) Manually close the gate up to 3cm before the closing
mechanical stop.
c) Place the closing bracket on the rack and slide it until the
limit-switch is activated (Fig. 13).
d) Mark the bracket position onto the rack, slightly open the
gate and fix the bracket to the rack.
e) Manually open the gate (gate end aligned to the pillar
edge).
f) Place the opening bracket on the rack and slide it until the
limit-switch is activated (Fig. 14).
g) Mark the bracket position onto the rack, slightly close the
gate and fix the bracket to the rack.
NB. Tagliare eventuali eccedenze di cremagliera
3.7.2 UNIVERSAL STEEL BRACKETS
a) Identify closing and opening bracket according to the motor
position against the gate (fig. 15).
b) Manually close the gate up to 3cm before the closing
mechanical stop.
c) Put the two fixing screws on the closing limit bracket.
d) Place the closing bracket on the rack and slide it until the
limit-switch is activated (Fig. 13).
e) Tighten the screws to fix the bracket onto the rack.
f) Manually open the gate (gate end aligned with the edge of
the pillar).
g) Put the two fixing screws on the opening limit bracket.
h) Place the opening bracket on the rack and slide it until the
limit-switch is activated (Fig. 14).
i) Tighten the screws to fix the bracket onto the rack.
Click!
Click!
ENGLISH
ENGLISH
Motor connection LEFT
CLOSING
limit-switch
OPENING
limit-switch
Motor connection RIGHT
CLOSING
limit-switch
OPENING
limit-switch
RIGHT motor
OPENING limit-switch
LEFT motor
CLOSING limit-switch
CLOSING
limit-switch
OPENING
limit-switch
CLOSING
limit-switch
OPENING
limit-switch
Motor connection RIGHT
Motor connection LEFT