1
Attention: before beginning anykind of procedure of installation is
absolutely necessary to read all this manuall.
2
Test/Control that the perfornces of the actuator auswer to your installation
needs.
3
Besides control that:
• The gare hinges are in good conditions and perfectly fattened.
• The gate has mechanicall stops in the opening and the closing.
INSTALLATION ADVICE
Connections:
•
See the “Operational Diagram” and refer to the control central scheme.
•
The electric cable in the exit from the actuator must be tight, but do an ample
curve towards the botton in order to avoid the reflux in the inside of the
actuator itself. (Fig. O)
•
The adjustment must be effected when the device has no power supply.
•
Foresee a omnipolar breaking device near to the apparatus (the contact
must measure at least 3 mm) Always protect the power supply using a 6A
automatic switch, or a 16A single-phase switch fises.
•
The power supply lines the motors, to the control unit and the connection
lines to the outfits must be sepated to avoid troubles which could generate
problems in the installation working.
•
Any outfits (of control or safety) eventually connected to the control unit
must be tension free.
Spare parts:
•
use esclusively original spare parts.
•
The batteries should be put with industril waste and not with domestic refuse .
(Law n. 475/88).
Installation:
•
In order to correctly use the product and to exclude the possibility of injury or
damage, refer to the "Generals" page enclosure, which is an integrated part
of this manual.
•
The use of this equipment must be in observance of the safety standards in
force in the country where it is installed, as well as the standards governing
proper installation.
•
Together with this manual is provided a label showing manufacturer's name and
product reference: please stick it insight on the equipment for future reference.
Warranty:
•
The warranty supplied by the manufacturer becomes void in the event of
interference, carelessness, improper use, lightening damage, power surges
or use by unqualified personnel.
•
The warranty will also become void in the event of the following: Failure to
observe the instructions given in the manuals supplied with the product.
The application of any part in a manner differing from that provided for
current legislation or the use of spare parts which are unsuitable and/or not
approved by manifacturer.
•
The manufacturer cannot be held responsible for damages due to improper
or unreasonable use.
ADVICES FOR THE INSTALLATION
1
Before starting the installation, please proceed with the test of the risks
concerning the gate to automate referring to the paragraph "Generalities"
that is an integral part of this manual. Please fill the technical table in and
remove the discovered risks. It will be obbligatory to install the
complementary security systems necessary in case that some risks remain.
2
Check the security regulations mentioned in the paragraph "Safety criteria".
3
Identify in the kit bought all the components that will be useful to the
installation referring to the drawing "kit composition".
4
Identify the left and/or the right operator referring to the drawing
“
”.
Operational Diagram
5) When the gate is closed, the bracket S1 must be fixed at minimum 30 mm.
Fix the bracket 1S as per the drawing in proximity of the extremity of the leaf
( see the drawing "Operating scheme").
N.B. It will be necessary to foresee a stiffener structure for the fixing of the
above mentioned bracket if the structure of the gate is light.
6
Grease the sliding points.
7
In order to take off the cover of the motor:
a) Pull the cap 1T off.
b) Unscrew the fixing screw of the cover.
c) Pull the cover of the motor up
8
Insert the sliding slide that contains the
motor in the bracket S1.
9
Insert the protective covering of the
cables in the apposite passage placed
on the side of the motor.
10 Connect the cables in the terminal boards.
11 Insert the cover and fix it.
12 Stretch the cables as per the "Operating scheme".
13 Connect the control unit and all the accessories
14 Program the radio receiver
15 Program The "Times of functioning”
In case of bad working, please read the paragraph " Anomalies and Advises".
If you do not find any solution please contact the nearest assistence centre.
ELECTROLOCKING
The electrolocking must be installed on the leaf that is the first to open and
must be connected to the apposite terminals of the control unit.
Position of the electrolocking:
POSITION 1: Closure between the leaves ( in this case it is necessary to use
the blot for closure on the second leaf )
POSITION 2: Closure on the ground ( in this case it is not necessary the
utilisation of the blot for closure )
Remember to eliminate the locking or in any case to make it be inoperative
blocking the closure in the opened position and to eliminate all the blots for
the closure.
MECHANICAL STOPS
At this point it is necessary to position the mechanical stops in order to effect
the stop in closing and the stop in opening of the leaf.
RELEASE OF THE MOTOR
a) Take the upper cap off.
b) Catch the metallic ring below and pull the chain until when the motor will
be a little bit lifted from the ground.
c) Hook the metallic ring placed at the head of the chain in a special
arresting hook that will have to be placed at the suitable height in order
to make the motor be inoperative.