30
Double fold
Irregular
accordion fold
Letter fold
Accordion
fold
Brochure fold
* Range of paper length which cannot be corrected to
±
0.2". The correction value differs according to the paper length.
10. FOLDING MISALIGNMENT
Correction restrictions
The positions of the folding stoppers of folding plates 1 and 2 may not be adjustable to
±
0.2"
according to the length of the paper used. This restriction is due to the length of the paper and
length of folding plates 1 and 2.
The restricted folding plate and correction details differ according to the folding mode and paper
length. Refer to the following table.
Folding
mode
Minimum paper length
that can be used
7.2"
7.2"
5.6"
5.6"
5.1"
Restricted range of
paper length*
7.2" to 8.1"
7.2" to 7.4"
7.2" to 8.1"
5.6" to 6.0"
5.6" to 6.1"
16.8" to 17.0"
16.7" to 17.0"
Restricted folding plate and
correction details
Correction by “–” key of folding plate 2
Correction by “–” key of folding plate 1
Correction by “–” key of folding plate 2
Correction by “–” key of folding plate 2
Correction by “–” key of folding plate 2
Correction by “+” key of folding plate 1
Correction by “+” key of folding plate 2
If the correction value is within the restricted range when this correction value is set using the
folding stopper adjusting key, the folding stoppers will stop at the maximum possible correction
value position. Set a valid correction value again using the folding stopper adjusting key.
Correction range
For standard folding, the adjustable range
using the folding stopper adjusting key is
within
±
0.2" from the center of the paper.
If set exceeding
±
0.2", the buzzer sounds
“pi.pi.pi”, and the folding stoppers will stop at
the
±
0.2" position of the adjustable range.
Center
Paper
Conveyance direction
Correction by the “+” key
0.2"
Correction by the “–” key
Within –0.2"