5. INSTALLATION 

Position your shower unit on the wall away from the 

direct spray of the shower and at about the same 

height as the showerhead position.

The shower unit should be positioned so that the 

showerhead cannot be immersed in the bath or 

shower tray when hanging down.

Remove the four screws securing the shower unit 

cover and remove the cover complete with the control 

knobs.

Place the shower unit on the wall and mark the 

location of the fi xing screws through the back plate.

Carefully drill the holes as marked using a sharp 

5.5mm masonry drill after fi rst having made certain 

there are no pipes or wires behind the proposed holes.

Fix the shower unit to the wall using the plugs and 

screws provided, do not fully tighten at this stage.

Inspiration

 

QI

Phased

Shutdown

Auto

Reset

Low

Eco

High

4. GENERAL LAYOUT OF A SHOWER INSTALLATION 

A TYPICAL INSTANTANEOUS ELECTRIC SHOWER 

INSTALLATION

Plan your own installation carefully. Check on the 

nearest and most readily accessible rising mains 

water supply, this may be beneath the bath or in the 

loft, where it feeds the cold water storage tank. Use 

only the cold rising water main supply.

Do not connect the shower unit to the outlet from the 

cold water tank.

Avoid connecting the shower unit, if possible, 

were it will be affected by water drawn off by other 

appliances, e.g. From the mains feed to the W.C. 

This may cause a drop in pressure too low for the 

shower unit to work correctly.

An isolating valve must be fi tted to comply with water 

regulations and for servicing purposes.

BATH

COLD WATER 

MAINS SUPPLY

SEPARATE PERMANENTLY 

CONNECTED SUPPLY 

FROM CONSUMER UNIT

ISOLATING 

STOP TAP

DOUBLE POLE

HEATER SWITCH

WALL MOUNTED

IN ACCORDANCE

WITH LOCAL

AUTHORITY

REGULATIONS

SHOWER

UNIT

BATHROOM

FLOOR

CEILING JOISTS

IMPORTANT

This appliance is not intended for use by persons (Including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their safety. Children should be 

supervised to ensure that they do not play with the appliance.

!

!

!

!

PRODUCT POSITIONING GUIDE

Shower unit can be mounted either 

side of riser rail

Height of 

showerhead 

and shower 

to suit user’s 

requirements

Mains cold water supply 

(either top, bottom, left, 

right or rear entry

25mm minimum

Outline of bath or 

shower tray

Spillover level

Spillover level

Soap dish

Hose retaining 

ring

Summary of Contents for Inspiration QI

Page 1: ...Instantaneous Electric Shower Installation Instructions IMPORTANT ThisStep by Stepguideshouldbegiventothecustomer afterinstallationanddemonstration InspirationQI...

Page 2: ...er in accordance with our instructions and recommendations WARNING DO NOT operate shower if frozen or suspected of being frozen It must thaw out before using DO NOT operate the unit if the showerhead...

Page 3: ...y Children should be supervised to ensure that they do not play with the appliance DEFAULT PLUMBING SETTING The shower unit is supplied for right hand installation To plumb the unit on the left you mu...

Page 4: ...ffattheisolatingswitchwhennot inuse 3 GENERALADVICETOSHOWERUNITUSERS Thefollowingpointswillhelpyoutounderstandhow yourMXshowerunitoperates Theflowrateofwaterpassingthroughtheshower unitdeterminesthewa...

Page 5: ...ttotheoutletfromthe coldwatertank Avoidconnectingtheshowerunit ifpossible wereitwillbeaffectedbywaterdrawnoffbyother appliances e g FromthemainsfeedtotheW C Thismaycauseadropinpressuretoolowforthe sho...

Page 6: ...ulloff 3 Simplyrefitblankingcaptotheinletpipeonthe righthandsideoftheunit 4 Re insertthemetalfixingclipensuringitispushed firmlyintothegroove 5 Whenleaktestingtheinstallationyoumustensure therearenole...

Page 7: ...iscordoperated Thewiringmustbe connectedtotheswitchwithouttheuseofaplugor socketoutlet ThecablesizerequiredisdeterminedbythekW ratingoftheshowerandthedistancebetweenthe showerandtheconsumerunit Thetab...

Page 8: ...ydebrisfrom thepipework cleanandrefit IMPORTANT Theshowerunitmustbefullofwaterbeforeheatsettingsareused IMPORTANT TurntheTemperaturecontrolknobanticlockwiseuntilthevalveisfullyopenbeforeswitchingonthe...

Page 9: ...this setting will only alter the flow of water not the water temperature ECO II setting This is the moderate power setting for economy during warmer months or when a cool shower is required Temperatu...

Page 10: ...owerthetemperatureontheheatdial 2 Cleantheshowerheadofanydirtanddebris restarttheshowerontheHotwatersetting 3 Confirmthatthemainswaterstopvalveis fullyopen 4 CleantheInlinefilter 5 Ensuretheisolationv...

Page 11: ...modificationsorlossordamagearisingtherefrom includingthecost ofrepairingdamage breakdown malfunctioncausedbycorrosion furring pipescaling limescale systemdebrisorfrost 8 Componentsand orunitsincluding...