background image

 

Installation Instructions 

& User Guide

Prior to Installation

Please leave these instructions 

with the end user

All products manufactured and supplied by Bristan are safe to use  

provided that they are installed, operated and receive regular  

maintenance in accordance with these instructions. 

This product needs to be installed in accordance with, and meet the 

requirements of the Water Supply (Water Fittings) Regulations 1999  

and current by-laws. For full Installation Requirements & Notes (IRN) 

please visit 

wras.co.uk/directory. 

Isolation valves must be fitted to the inlet water supplies to ensure ease 

of future maintenance. Before installing this product the water supply 

must be thoroughly flushed in order to remove any swarf, solder etc.  

Full access must be made available for future maintenance/ 

servicing purposes.

Before drilling into walls, check that there are no hidden electrical  

wires, cables or water supply pipes. This can be checked with the  

aid of an electronic detector.

If power tools are used do not forget to:  

 

- Wear eye protection

 

- Unplug equipment after use

This product must not be modified in any way  

as this will invalidate the guarantee.

If in doubt, contact a registered plumber, your Local Water  

Authority or the Secretary of the Institute of Plumbing,  

address as follows:-

The Institute of Plumbing,

64 Station Lane,

Hornchurch,

Essex,

RM12 6NB, Tel: 01708 472791

6

Attach the fixed head. 

To adjust height of head, slide the riser 

to desired height (see step 2).

3

1

Rotate the  

shroud until  

the opening  

aligns with the  

isolation screw.

Remove the 

concealing cap 

from the shroud.

2

5

         Identify the    

   required position of 

the valve and prepare 

the water supply pipes. 

Supply pipes should be 

150mm apart.

Using the backplate 

supplied with the 

wallmount, mark and 

drill holes.

Secure the isolator 

onto the backplate 

ensuring the olive is 

positioned over the 

pipework correctly.

Push shrouds to the back 

of the wall outlet, securing 

them against the rubber 

fixing plate

4

3

1

Installation

150mm C

entr

es

1

Isolation

2

Secure the rubber backplate 

and backplate into place.

Insert filter washer and 

secure the shower to 

the wall mount.

21mm

21mm

REMEMBER 

hot on the left, 

cold on the 

right

To reduce the build up of limescale 

and to ensure this shower works to 

its maximum performance we 

recommend this shower is serviced 

every 6-12 months depending on the 

hardness of your water.

Servicing Intervals

Turn the screw to isolate the water. 

Reverse the process when turning  

the water back on.

4

5

Riser Installation

2

Product Code: BUZ2 SHXDIVCTFF C (D4)

IMPORTANT

Pack Contents

150mm

Centres

1.0

5.0

Pressure

BAR

0.2

4.0

2.0 3.0

Pressure

BAR

1.0

5.0

0.2

4.0

2.0

3.0

60°C

65°C

Specifications

Maximum Static Pressure: 

10.0 bar

Inlet Water Temperature

Inlet Connections

Min: 

1.0 bar

Max: 

5.0 bar

Working Pressures

The inlet hot water must 

be at least 10°C above the 

required blend temperature.

Factory pre-set

38°C

Inlet Dimensions

5°C

25°C

Cold Water Supply

Min: 

5°C

 Max: 

25°C

Hot Water Supply

Tools You’ll Need

60-65°C Recommended

x1

x2

x2

x2

x2

x8

x8

x2

x2

x2

x2

x1

x1

x2

x1

x1

x1

x1

x1

x1

x1

x1

Flat Head Screwdriver

Cross Head Screwdriver

Hexagonal Keys

Pipe Cutter

Drill

Spanner

Safety Glasses

Detector

Using a spirit level 

to ensure the 

riser is positioned 

correctly, use 

the assembled 

riser to mark the 

desired position 

of the bracket.

Secure the 

bracket to  

the wall.

Secure the riser 

bracket and riser 

rail.

Slide the 

bracket onto the 

riser rail, then 

push the riser 

extension into 

the riser rail.   

 

Press & hold 

knob on the 

bracket to slide 

up or down.

Tighten nut to 

secure riser.

To adjust the 

height unscrew 

the nut and 

move the pole 

to the desired 

height. Tighten 

nut again to 

secure in place. 

1/2” 

Compression

 

Reviews: