15 to 17
TROUBLESHOOTING
BURNER AND/OR PILOTS NOT
TURN ON
GAS SUPPLY TO COOKING
EQUIPMENT IS OFF
TURN ON GAS SUPPLY
UNIT PRODUCING CARBON
DEPOSITS
GAS TYPE
VERIFY CORRECT GAS
GAS SUPPLY PRESURE
CONTACT LOCAL GAS SUPPLIER
PRIMARY AIR NOT ADJUSTED
PROPERLY
ADJUST AIR SHUTTER
ORIFICE TOO BIG
VERIFY ORIFICE SIZE
PILOT WILL NOT REMAIN LIT
PILOT FLAME NOT ADJUSTED
ADJUST PILOT FLAME
DRAFT CURRENTS NEAR
EQUIPMENT
FIX DRAFT
NOT ENOUGH VENTILATION
CONTACT HVAC CONTRACTOR
DEBRIS OR GREASE CLOGGING
PILOT BURNER
CLEAN DEBRIS AND GREASE
FROM PILOT BURNER
EXCESSIVE FLARE-UP
OVERLOAD OF OIL AND
LEFTOVERS
CLEAN AND PREPARE PAN
NOT HEATING PROPERLY
ORIFICES DIRTY/CLOGGED
CLEAN ORIFICE, MAKE SURE
THERE IS NO RESTRICTION IN THE
ORIFICE BURNER
LOW GAS PRESSURE
INCREASE GAS PRESSURE TO 5”
WC (NAT) OR 10” WC (L.P.)
GRATES DIRTY/CLOGGED
CHECK AND CLEAN TOP GRATES
IF THE VENTILATION IS TO
STRONG IT WILL DRAFT HEAT
FROM THE COOKING/BROILING
SURFACE
CALL HVAC CONTRACTOR