Provisions  shall  be  incorporated  in  the  design  of  the  kitchen,  to  ensure  adequate  supply  of  fresh  air  and 
adequate clearance for air openings into the combustion chamber, for proper combustion, and ventilation. For 
proper operation of the appliance, do not obstruct the flow of combustion and ventilation air. 

The installation must conform with local codes, or in the absence of local codes, to the national fuel gas code, 
ANSI Z223.1 (or latest addenda). The Appliance and its individual shut off valve must be disconnected from the 
gas supply piping system during any pressure testing of that system in excess of ½ PSI (3.45Kpa). 

The  appliance  must  be  isolated  from  the  gas  supply  piping  system  by  closing  its  individual  manual  shut  off 
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ PSI 
(3.45Kpa). 

The gas supply line must be at least the same size as the gas inlet of the appliance. 

FLEXIBLE COUPLINGS, CONNECTORS AND CASTERS 

For an appliance equipped with casters the installation shall be made with a connector that complies with the 
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances, 
CAN/CGA-6.16, and a quick  disconnect device that complies with the  standard for Quick Disconnect Devices 
for Use  with  Gas  Fuel,  ANSI  Z21.41, or  Quick  Disconnect Devices  for  Use  with Gas  Fuel,  CANI-6.9.  Adequate 
means must be provided to limit the movement of the appliance without depending on the connector and the 
quick-disconnect device or its associated piping to limit the appliance movement. 

Restraining devices may be attached to the back frame/panel of the unit. 

HIGH SHELF ASSEMBLY 

(1) Mount the back guard/ flue riser to the range with sheet metal screws in the back.
(2) Mount  the  high  shelf  to  the  riser  with  bolts  provided  (see  attachment  at  the  end  of  this  manual  for  a
diagram that describes the installation of the back guard / flue riser).
NOTE: If a Salamander broiler / Cheese Melter is to be mounted on a range, read installation instructions for
Salamander broiler / Cheese Melter before installing high shelf. Special care must be taken to ensure that the
gas supply piping and/or gas pressure regulator is not exposed to exhaust gases, or elevated temperatures.
The gas supply (service) line must be the same size or greater than the inlet line of the appliance. Royal ranges
and ovens u

se a 3/4” NPT inlet. Sealant on all pipe joints must be resistive to LP gas.

OPERATING INSTRUCTIONS

: Before lighting, check all joints in the gas supply line for leaks. 

DO NOT USE OPEN 

FLAME TO CHECK FOR LEAKS! USE SOAP AND WATER SOLUTION. 

Putting an open flame beside a new gas connection is extremely dangerous. 
LIGHTING: Initial pilot lighting: 
CAUTION: When lighting pilots  and checking  for leaks, do not  Stand with your face  close to the combustion 
chamber. 

Summary of Contents for Sierra SR-10-60

Page 1: ... 48 SR 4B 36G 60 SR 6B 24G 60 SR 6B 24RG 60 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS RANGE 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 12000 BISCAYNE BLVD STE108 MIAMI FL 33181 TEL 786 600 4687 1 844 218 8477 sales mvpgroupcorp com www mvpgroupcorp com ...

Page 2: ...ARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lis...

Page 3: ...and cannot be adjusted If converting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Me...

Page 4: ...as Fuel ANSI Z21 41 or Quick Disconnect Devices for Use with Gas Fuel CANI 6 9 Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached to the back frame panel of the unit HIGH SHELF ASSEMBLY 1 Mount the back guard flue riser ...

Page 5: ...y valve and then to the pilot burner Gas flow is controlled by the safety valve Oven pilot lighting or relighting is to be completed in the following sequence 1 Turn the oven thermostat knob to off and wait 5 minutes 2 Remove the oven s lower kick plate by lifting up and out This exposes the pilot safety valve and the igniter button 3 Make sure any accumulated gas has dispersed Since propane gas i...

Page 6: ...e oven liner panels Wash all the above with hot soapy water then reassemble Baked on spills may be loosened and stubborn stains removed with ordinary household ammonia and scrubbing with a nylon pad in a cold oven only Do not allow spray type oven cleaners to come into contact with the temperature probe in the oven After cleaning the oven rinse well with 1 4 cup of vinegar to one quart of clear wa...

Page 7: ...ss than under any circumstances All connections must be tested with a soapy water solution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the installation instructions the serving gas supplier or the appl...

Page 8: ...ly piping system at test pressure equal to or less than psi 3 45kpa CLEARANCES The appliance area must be kept free and clear of all combustibles SR Series products are for installation in Non Combustible locations only COMBUSTIBLE NON COMBUSTIBLE SIDES 12 Inches 0 Inches REAR 8 Inches 0 Inches FLOOR 6 Inches 0 Inches AIR SUPPLY VENTILATION The area in front of around and above the appliance must ...

Page 9: ...ers operating gas pressure in inches WC and whether the appliance is orifices for natural or propane gas When communicating with factory about a unit or requesting for special parts or information Rating plate data is essential for proper identification SIERRA COOKING APPLIANCES MUST BE CONNECTED ONLY TO THE TYPE OF GAS ACCESSORIES INSTALLATION BACKSPLASH AND SHELF INSTALLATION MODELS SRR 4 24 SRR...

Page 10: ... INSTALLATION Identify the assemblies to be fitted over the equipment Make sure you have all the tools and fasteners listed Item Description Quantity PC 1 M6 SCREW FLAT 2 2 HEX SCREW 10mm 10 Flat screwdriver Hex Nutdriver ...

Page 11: ...11 to 17 Remove the 3 rear screws of the unit Place the backsplash and make sure that the manifold fits in the hole on the right side support push ...

Page 12: ...12 to 17 Place and tight the hex screws in the shown positions SHELF INSTALLATION Place the shelf over the backsplash and hook it on the very top of it Back Splash Shelf ...

Page 13: ...13 to 17 Fit the M6 screws on the inside of the shelf to secure it in position REMOVE THE DOOR ...

Page 14: ... in both hinges you can find 2 pieces of it in carton legs box STEP 2 Hold onto both hinges with your hands STEP 3 Raise the door until the door is at a 45 degrees angle STEP 4 Pull the door towards you and lift up To put the door back in reverse these instructions ...

Page 15: ...FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CLEAN ORIFICE MAKE SURE THERE IS NO RESTRICTION IN THE ORIFICE BURNER LOW GAS PRESSURE INCREASE GAS PRESSURE TO...

Page 16: ...Sierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional...

Page 17: ...7 514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canada H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...

Reviews: