background image

3 to 17 

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE 

All equipment manufactured by SIERRA RANGE. is for use with the type of gas specified on the rating plate and 
for installation will be in accordance with National Fuel Gas Code ANSI Z223.1 (latest edition) 

IMPORTANT: Installing, Operating and Service Personnel: 

Qualified, certified licensed and/ or authorized personnel who are familiar with and experience in state/local 
installation codes should perform installation of the equipment. Qualified or authorized personnel who have 
read  this  manual  and  are  familiar  with  the  functions  of  the  equipment  should  perform  operation  of  the 
equipment. 

Qualified personnel who are knowledgeable with Sierra equipment should perform service of the equipment. 

The BTU input rating on all equipment is calibrated for elevations up to 2,000 feet above sea level. All orifice 
drill sizes are referenced for operation at or below this altitude. For operation at elevations above 2,000 feet, 
the BTU rating must be reduced 4% for each 1,000 feet of elevation or the orifice drill size must be changed 
appropriately. For high altitude drill sizes, call your local gas company or Factory Authorized Service Center. 

All units are equipped with fixed orifices and cannot be adjusted. If converting the gas appliance from natural 
to propane, or vice versa, all orifices and the regulator must be changed. The correct type of gas, for which the 
unit is configured, is noted on the name plate. The type of gas specified MUST be used. For proper conversion, 
contact a qualified service technician or your Factory Authorized Service Center. 

SHIPPING DAMAGE CLAIM PROCEDURE 

Merchandise must be inspected prior to the carrier leaving your premises. Damage must be noted in writing 
on the BOL and pictures must be taken at this time. 

- For any goods shipped prepaid by MVP Group Corp., and the goods are damaged and/or lost in transit, please

 

call the Logistics Department at MVP immediately (1-888-275-4538)

- MVP Group will not be held responsible for damages that are not notated on the BOL or not reported within

 

5 business days of being delivered.

- For  goods  shipped  via  3rd  party  carrier,  any  claim  for  damages  or  loss  must  be  made  by  the  consignee

 

directly with the carrier. MVP Group Corp. assumes no responsibility for damage or loss while in transit.

INSTALLATION INSTRUCTIONS 

Gas pressure regulator provided with the equipment must be installed when the appliance is connected to gas 
supply. The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning 
liquid,  broom,  rags, etc.  Proper  clearances must  be  provided  at  the  front  of  the  appliance  for  servicing  and 
proper operation. 

Summary of Contents for Sierra SR-10-60

Page 1: ... 48 SR 4B 36G 60 SR 6B 24G 60 SR 6B 24RG 60 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS RANGE 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 12000 BISCAYNE BLVD STE108 MIAMI FL 33181 TEL 786 600 4687 1 844 218 8477 sales mvpgroupcorp com www mvpgroupcorp com ...

Page 2: ...ARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lis...

Page 3: ...and cannot be adjusted If converting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Me...

Page 4: ...as Fuel ANSI Z21 41 or Quick Disconnect Devices for Use with Gas Fuel CANI 6 9 Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached to the back frame panel of the unit HIGH SHELF ASSEMBLY 1 Mount the back guard flue riser ...

Page 5: ...y valve and then to the pilot burner Gas flow is controlled by the safety valve Oven pilot lighting or relighting is to be completed in the following sequence 1 Turn the oven thermostat knob to off and wait 5 minutes 2 Remove the oven s lower kick plate by lifting up and out This exposes the pilot safety valve and the igniter button 3 Make sure any accumulated gas has dispersed Since propane gas i...

Page 6: ...e oven liner panels Wash all the above with hot soapy water then reassemble Baked on spills may be loosened and stubborn stains removed with ordinary household ammonia and scrubbing with a nylon pad in a cold oven only Do not allow spray type oven cleaners to come into contact with the temperature probe in the oven After cleaning the oven rinse well with 1 4 cup of vinegar to one quart of clear wa...

Page 7: ...ss than under any circumstances All connections must be tested with a soapy water solution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the installation instructions the serving gas supplier or the appl...

Page 8: ...ly piping system at test pressure equal to or less than psi 3 45kpa CLEARANCES The appliance area must be kept free and clear of all combustibles SR Series products are for installation in Non Combustible locations only COMBUSTIBLE NON COMBUSTIBLE SIDES 12 Inches 0 Inches REAR 8 Inches 0 Inches FLOOR 6 Inches 0 Inches AIR SUPPLY VENTILATION The area in front of around and above the appliance must ...

Page 9: ...ers operating gas pressure in inches WC and whether the appliance is orifices for natural or propane gas When communicating with factory about a unit or requesting for special parts or information Rating plate data is essential for proper identification SIERRA COOKING APPLIANCES MUST BE CONNECTED ONLY TO THE TYPE OF GAS ACCESSORIES INSTALLATION BACKSPLASH AND SHELF INSTALLATION MODELS SRR 4 24 SRR...

Page 10: ... INSTALLATION Identify the assemblies to be fitted over the equipment Make sure you have all the tools and fasteners listed Item Description Quantity PC 1 M6 SCREW FLAT 2 2 HEX SCREW 10mm 10 Flat screwdriver Hex Nutdriver ...

Page 11: ...11 to 17 Remove the 3 rear screws of the unit Place the backsplash and make sure that the manifold fits in the hole on the right side support push ...

Page 12: ...12 to 17 Place and tight the hex screws in the shown positions SHELF INSTALLATION Place the shelf over the backsplash and hook it on the very top of it Back Splash Shelf ...

Page 13: ...13 to 17 Fit the M6 screws on the inside of the shelf to secure it in position REMOVE THE DOOR ...

Page 14: ... in both hinges you can find 2 pieces of it in carton legs box STEP 2 Hold onto both hinges with your hands STEP 3 Raise the door until the door is at a 45 degrees angle STEP 4 Pull the door towards you and lift up To put the door back in reverse these instructions ...

Page 15: ...FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CLEAN ORIFICE MAKE SURE THERE IS NO RESTRICTION IN THE ORIFICE BURNER LOW GAS PRESSURE INCREASE GAS PRESSURE TO...

Page 16: ...Sierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional...

Page 17: ...7 514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canada H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...