3 to 17
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
All equipment manufactured by SIERRA RANGE. is for use with the type of gas specified on the rating plate and
for installation will be in accordance with National Fuel Gas Code ANSI Z223.1 (latest edition)
IMPORTANT: Installing, Operating and Service Personnel:
Qualified, certified licensed and/ or authorized personnel who are familiar with and experience in state/local
installation codes should perform installation of the equipment. Qualified or authorized personnel who have
read this manual and are familiar with the functions of the equipment should perform operation of the
equipment.
Qualified personnel who are knowledgeable with Sierra equipment should perform service of the equipment.
The BTU input rating on all equipment is calibrated for elevations up to 2,000 feet above sea level. All orifice
drill sizes are referenced for operation at or below this altitude. For operation at elevations above 2,000 feet,
the BTU rating must be reduced 4% for each 1,000 feet of elevation or the orifice drill size must be changed
appropriately. For high altitude drill sizes, call your local gas company or Factory Authorized Service Center.
All units are equipped with fixed orifices and cannot be adjusted. If converting the gas appliance from natural
to propane, or vice versa, all orifices and the regulator must be changed. The correct type of gas, for which the
unit is configured, is noted on the name plate. The type of gas specified MUST be used. For proper conversion,
contact a qualified service technician or your Factory Authorized Service Center.
SHIPPING DAMAGE CLAIM PROCEDURE
Merchandise must be inspected prior to the carrier leaving your premises. Damage must be noted in writing
on the BOL and pictures must be taken at this time.
- For any goods shipped prepaid by MVP Group Corp., and the goods are damaged and/or lost in transit, please
call the Logistics Department at MVP immediately (1-888-275-4538)
- MVP Group will not be held responsible for damages that are not notated on the BOL or not reported within
5 business days of being delivered.
- For goods shipped via 3rd party carrier, any claim for damages or loss must be made by the consignee
directly with the carrier. MVP Group Corp. assumes no responsibility for damage or loss while in transit.
INSTALLATION INSTRUCTIONS
Gas pressure regulator provided with the equipment must be installed when the appliance is connected to gas
supply. The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning
liquid, broom, rags, etc. Proper clearances must be provided at the front of the appliance for servicing and
proper operation.