7
110 – 220 VAC Power Source –
Single Phase Only
Use Color coded terminals for High
Voltage Input to hook up inside D3
Site Power Available
Input Power Configuration for 110 – 220 VAC
High Voltage A/C Typical Conventions, single phase (USA wiring
convention):
Color
Symbol
Description
Black
L
Line Conductor, aka: “Hot” wire
White
N
Neutral Conductor
Green
G
Ground Wire, Chassis Ground
Input Specifications
Input Voltage: 90-264 VAC, (127-370 VDC)
Frequency Range: 47- 63 HZ
Input Current @ Full Load(Typ.): 1.8A@115VAC,
1.0A@230VAC
Recommended Min. Circuit Breaker: 6 A (type C)
Int. Electrical. Working Temp*: -20 ~ +70C
MTBF: 353.6Khrs min. MIL-HDBK-217F(25C)
Power Available to Camera & Accessories (max.)
MVP using 110/ 220 VAC input to S-Type enclosure
Using
ONE
Output
Using
BOTH
Output Channels (12VDC & 24VDC)
Model
12 VDC Output
OR
24 VDC
Heater Blower
25 watts
or
25 watts
25 watts first channel, 5 watts on second Channel
Tornado
25 watts
or
50 watts
25 watts first channel, 25 watts on second channel
Ring of Fire
25 watts
or
25 watts
25 watts first channel, 5 watts on second channel
Run 110-220 VAC into D3 via
weatherproof wiring ports provided.
Connect wires to appropriate Color
Coded terminal shown here
! Use
Single Phase
Voltage Wiring
Only
!
* Shut off
all power before and during wiring & servicing!
*All Wiring must be done by a Qualified technician
*Observe all local and applicable electrical codes
Inside all D3-MVP is a Chassis similar to shown
All Wiring Connections are
to be made fully inside of D3
The MVP comes ready for 110-220VAC Input power
Summary of Contents for D3 SERIES
Page 1: ...PRODUCT INSTRUCTIONS D3 SERIES CAMERA ENCLOSURES ...
Page 6: ...3 ...
Page 14: ...11 ...
Page 18: ...15 D3 Exploded Detail ...
Page 19: ...16 D3 Mounting Detail ...