Flue Box Kit
Models:
BOX03706
BOX03707
BOX03708
BOX03709
KIT COMPONENTS:
Use these instructions when replacing the flue box:
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES.
SERVICE INSTALLER'S
GUIDE
▲
WARNING
!
Disconnect power to the unit before removing the blower
door. Failure to follow this warning could result in personal
injury from moving parts.
18-CH99D1-1
Item
No.
Drawing No.
Description
Qty
1
A340089P01
PRESSURE SWITCH TUBE
1
2
D345926P01
FLUE BOX
1
3
18-CH99CHD1-1
INSTALLER'S GUIDE
1
SHARP EDGE HAZARD!
Failure to follow this Caution could result in property damage or
personal injury. Be careful of sharp edges on equipment or any cuts
made on sheet metal while installing or servicing.
▲
CAUTION
!
▲
WARNING
!
INSTALLATION OR REPAIRS MADE BY UNQUALIFIED
PERSONS CAN RESULT IN HAZARDS TO YOU AND OTH-
ERS. INSTALLATION MUST CONFORM WITH LOCAL CODES
OR, IN THE ABSENCE OF LOCAL CODES, WITH CODES OF
THE COUNTRY HAVING JURISDICTION. THE INFORMATION
CONTAINED IN THESE INSTRUCTIONS IS INTENDED FOR
USE BY A QUALIFIED SERVICE TECHNICIAN FAMILIAR WITH
SAFETY PROCEDURES AND EQUIPPED WITH THE PROPER
TOOLS AND TEST INSTRUMENTS. FAILURE TO CARE-
FULLY READ AND FOLLOW ALL INSTRUCTIONS IN THESE
INSTRUCTIONS CAN RESULT IN FURNACE OR BOILER
MALFUNCTION, PROPERTY DAMAGE, PERSONAL INJURY
AND/ OR DEATH.
Removing the flue box
1. Turn the thermostat to the off position.
2. Disconnect all electric power to the unit.
3. Shut off the gas supply to unit.
4. Remove the furnace door.
5. Remove the inducer assembly. Retain the screws
for reinstallation.
6. Disconnect the pressure switch tubing from the flue
box.
7. Remove the flue box. Retain the screws for
installation of the new flue box.
8. Clean the heat exchanger surface.
Note: Make sure to remove all gasket material.
Furnace
Sealant
Flue Box screws
1
2