background image

Table of Contents 

Limited Warranty Info ..………………………………………………………………………………………………………………………………………………………………………………... 0

Product Installation Precautions, Warnings, and Installation Guidelines  ......................................................................................................... 1 

Conduit Guidelines ......................................................................................................................................................................................... 2 

Vent Plugs Installation Guide  ......................................................................................................................................................................... 3 

D3 Component Checklist for camera installation / Camera Mount Bracket ...................................................................................................... 4

 

Intro to  MVP Power  ...................................................................................................................................................................................... 5 

24V Input MVP Power  ................................................................................................................................................................................... 6 

High Voltage Input MVP Power  ...................................................................................................................................................................... 7 

Camera Power Setup

 (Standard 12VDC Connector and NON-STANDARD 12VDC CONNECTOR)

 .......................................................................... 8 

Camera Installation 

(Generic)

 ......................................................................................................................................................................... 9 

Steady Step Mounting Instructions ......................................................................................................................................................... 10, 11 

COOLDOME Input Configuration ............................................................................................................................................................. 12, 13 

Power Specifications – High Voltage Inputs................................................................................................................................................... 14 

D3 Exploded View ........................................................................................................................................................................................ 15 

D3 Mounting Template ................................................................................................................................................................................. 16

Summary of Contents for D3 SERIES

Page 1: ...PRODUCT INSTRUCTIONS D3 SERIES CAMERA ENCLOSURES ...

Page 2: ...for camera installation Camera Mount Bracket 4 Intro to MVP Power 5 24V Input MVP Power 6 High Voltage Input MVP Power 7 Camera Power Setup Standard 12VDC Connector and NON STANDARD 12VDC CONNECTOR 8 Camera Installation Generic 9 Steady Step Mounting Instructions 10 11 COOLDOME Input Configuration 12 13 Power Specifications High Voltage Inputs 14 D3 Exploded View 15 D3 Mounting Template 16 ...

Page 3: ...tional Security Industry Organization Furthermore Dotworkz Systems shall have no liability where a schedule is specified for regular replacement maintenance or cleaning of certain parts based on usage that the end user has failed to abide to such schedule attempted repair by non qualified personnel operation of the Product outside of the published environmental and electrical parameters if such Pr...

Page 4: ...presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance UNPACKING Unpackcarefully Electro...

Page 5: ...t to eliminate any moisture dust and insect damage safety performance reliability and maintenance related issues Use of Electrical Conduit without sealing the entry ports inside wire feeds within Camera Enclosure will subject the inside of your enclosure to possibility of condensation driven moisture dust and insect contamination hazards Dotworkz has provided each enclosure with two Cable Gland St...

Page 6: ...3 ...

Page 7: ...y Available by special order Axis 231D 232D DVTel 9840 Merit LiLin PIH 7000 7600 7625 PiXORD P 463T Fast Speed Dome Pelco Spectra IV Sony SNCRH124 SNC RS44N SNC RS46N Toshiba IK DP30A Component Check List For D3 Included Standard Hardware for Camera Mounting 20 24V Input Blue Bypass Cable In MVP models only 1 20 ...

Page 8: ...gh Voltage 110 220 VAC Or Low Volt 24 VAC VDC Or Output Voltage to Power Camera MVP provides step down voltage to supply camera power for 12VDC and 24V Cameras 24V Camera Supply 24V output depends on Site Power Input for either 24V Direct Current or Alternating Current see table above Voltage Matrix for Input Output Optional 24VAC Transformer Module available for 24VAC only cameras to convert 110 ...

Page 9: ... insert similar Plug on 24V Bypass Cable Tighten screws on plug to secure Locate 24V Bypass Cable in Hardware Pack Provided 24 VDC Connect wires to appropriate Color coded terminal shown above 24 VAC hook up has no polarity 24 VDC Color Code Red Positive Blue Negative When all wiring is complete secure screws from plug to panel mount Then secure all wiring to be sure it does not interfere damage f...

Page 10: ...ories max MVP using 110 220 VAC input to S Type enclosure Using ONE Output Using BOTH Output Channels 12VDC 24VDC Model 12 VDC Output OR 24 VDC Heater Blower 25 watts or 25 watts 25 watts first channel 5 watts on second Channel Tornado 25 watts or 50 watts 25 watts first channel 25 watts on second channel Ring of Fire 25 watts or 25 watts 25 watts first channel 5 watts on second channel Run 110 22...

Page 11: ...et Right Angle Standard Inline version If you IP camera s power connector is different but still accepts up to 13VDC for power please see our section on Camera Power Setup NON STANDARD CONNECTOR for instructions on how to power your camera Below are pictures of typical NON STANDARD CONNECTORS DC plugs with NO center pin Terminal pin connectors Terminal connector ...

Page 12: ... Steady Step camera bracket is an easy to adjust stable mounting system that adjusts to fit virtually every major PTZ camera on the market By utilizing the lower mounts around the lens on hinged lower of D3 virtually any PTZ or Mini Dome Camera can be mounted into the enclosure at any level By using the included 1 8 tall brass standoff set the Steady Step system can be attain half steps of 1 8 ste...

Page 13: ...ments To adjust 1 8 between step settings add 1 8 brass male male hex stand off ITEM NO 6 shown in detail D below and provided in D3 hardware pack by threading on top of movable slide bracket of steady step bracket system then fastening camera bracket CB 1007 or AB 1007 ...

Page 14: ...11 ...

Page 15: ... load it is best to run two pairs individually So each 12VDC paired wiring runs load of one cooler Low Voltage 12 VDC Output Terminals Color Symbol Terminals Description Red V 9 10 11 Positive VDC Black V 12 13 14 Negative VDC 12 VDC Cable to COOLDOME Turn Off Power or leave power disconnected during Installation of All Wiring Follow all local and relevant electrical codes standards Test all Wirin...

Page 16: ... power and COOLDOME Voltage drop is based on fully loaded cooler engaged conditions and camera powered allowing up to 3 amps at typical ambient temperatures of 100F Inside D3 CD at rear of upper on enclosure will be two pairs of color coded screw terminal blocks to conveniently and securely attach low voltage wiring Always check voltage to assure 12VDC is properly wired into enclosure and observe ...

Page 17: ...14 D3 High Voltage Power Supply Specifications D3 COOLDOME SP 500 12 Power Supply D3 MVP Models High Voltage Inputs ...

Page 18: ...15 D3 Exploded Detail ...

Page 19: ...16 D3 Mounting Detail ...

Reviews: