HDMI 8x8 Matrix Switch Kit, HDBT, PoC, 4K/60
Installation & Operation Manual
© MuxLab Inc. 2019
14
5.3.3. RS232 Communication Commands
Note
:
1)
In the below RS232 commands, the square brackets “[” and “]” are only symbols to
help describe the RS232 command syntax, and they do not need to actually be
typed in when entering a command.
2)
Please remember to end each command with the ending symbols “.” and “;”.
3)
Type each command in carefully, as they are case-sensitive.
RS232 Port Settings:
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
Command
Function
H
List the commands available
STA
Shows global system status
SET RST
Resets to factory default
SET ADDR XX
Sets system address to xx [XX = 00 -
99]
SET LCD ON Tx
Sets LCD remain On time [x = 0-3] [0
= Always, 1 = 15 secs, 2 = 30 secs, 3
= 60 secs]
SET KEY LOCK ON/OFF
Sets key lock on/off
GET ADDR
Get system address
GET STA
Get system status
GET Inx SIG STA
Get input x status [x = 0-8; 0 = all]
GET LCD ON T
Get LCD remain On time status
GET KEY LOCK
Get key lock status
Output Setup Commands
SET OUTx VS INy
Sets output x to input y [x = 0-8] [0 =
All, y = 1-8]
SET OUTx HP VIDEOy
Sets HDMI output video mode [x = 0-
8] [0 = All, y = 1, 3; 1 = bypass; 3 = 2K
-> 4K
SET OUTx TP VIDEOy
Sets HDBT output video mode [x = 0-
8] [0 = All, y = 2, 5; 2 = 2K -> 4K, 5 =
HDBT mode]
SET OUTx EXA EN/DIS
Sets
external
audio
output
enable/disable x to input y [x = 0-8] [0
= All]