Operating Manual FS750E 

 

 

 

Mütec Instruments GmbH

 

Tel.: +49 (0) 4185-80 83-0 

E-Mail

[email protected]

 

Bei den Kämpen 26

 

Fax: +49 (0) 4185-80 83-80 

Web:    

www.muetec.de

 

D-21220 Seevetal-Ramelsloh 

1

 

Classification of the safety instructions 

This manual contains instructions that you have to observe for your personal safety as 
well as to avoid material damage. These instructions are highlighted using a triangular 
warning sign and shown as follows, depending on the degree of risk. 
 

 

HAZARD 

means that death or severe physical injury will occur  if the appropriate precautionary 
measures are not taken. 
 

 

WARNING 

means that death or severe physical injury may occur if the appropriate precautionary 
measures are not taken.  
 

CAUTION

 

with  a  triangular  warning  sign  means  that  minor  physical  injury  may  occur  if  the 
appropriate precautionary measures are not taken. 
 

CAUTION

 

without  a  triangular  warning  sign  means  that  material  damage  may  occur  if  the 
appropriate precautionary measures are not taken. 
 

ATTENTION

  

means that an undesired result or state may ensue if the corresponding instruction is 
not followed. 
 

NOTE

  

denotes  important  information  about  the  product,  handling  of  the  product  or  the 
respective part of the documentation, is aimed at drawing special attention to the latter 
and should be complied with. 
 
In addition to the instructions in this manual, the generally applicable safety and accident 
prevention regulations must be observed. 
If  the  information  contained  in  this  document  should  not  be  sufficient  in  any  specific 
case, you can obtain more detailed information from our telephone service. 
Please read this manual carefully prior to installation and commissioning. 
 

CE mark  

This product meets the specifications according to the EMC Directive 2014/30/EU and 
the Low Voltage Directive 2014/35/EU. 

 

 

Summary of Contents for FS750E

Page 1: ...14 Operating Manual FS750E M tec Instruments GmbH Tel 49 0 4185 80 83 0 E Mail muetec muetec de Bei den K mpen 26 Fax 49 0 4185 80 83 80 Web www muetec de D 21220 Seevetal Ramelsloh Dust monitoring w...

Page 2: ...Instruments GmbH 2019 All rights reserved This document is copyright protected It supports the user in making reliable and efficient use of the unit Transmission and duplication of this document as we...

Page 3: ...troduction 6 4 System Design 7 5 General information on construction and operation 7 6 Mounting Instructions 8 6 1 Selection of the mounting position 8 6 2 Sensor Mounting 8 6 3 Transmitter Mounting 9...

Page 4: ...sical injury may occur if the appropriate precautionary measures are not taken CAUTION without a triangular warning sign means that material damage may occur if the appropriate precautionary measures...

Page 5: ...extended nor limited by the information contained in the manual The content reflects the technical state of the art regarding printing It is subject to technical modifications in the course of furthe...

Page 6: ...and the opposite wall The measurement system is based on the triboelectric effect Particles collide permanently with each other or with other materials e g the wall Because of this process the particl...

Page 7: ...General information on construction and operation Safety instructions If the device can no longer be operated safely it must be put out of operation and secured to prevent unintentional operation The...

Page 8: ...urement window is performed with an 18 mm drill bit Therefor the previously welded sleeve serves as a drilling template After drilling the borehole on the inner pipe wall needs to be trimmed as much a...

Page 9: ...tter Mounting Mount the transmitter on a 35 mm DIN rail according to EN 60715 Install the module in a suitable housing to meet the requirements for the protection class The DIN rail transmitter should...

Page 10: ...pin T2 and the shared ground on pin T4 Shielded connection cables should be used Connect the shield with the ground rail DIN rail As an alternative unshielded connection cables can be used if the cabl...

Page 11: ...iometer maps the lower measuring range to a current output of 4mA By adjusting the potentiometer to the lower or upper end the current output is increased or decreased by up to 4mA respectively If the...

Page 12: ...g material Aluminum Material sensor rod V2A V4A option Isolator PPS Protection class IP65 Weight 700g Tightening torque mounting 40Nm Storage temperature 20 C to 70 C not condensing Operating temperat...

Page 13: ...supply DC voltage 24 VDC 20 to 30 Power consumption max 2 W Power LED green good condition of power supply Housing Material Polyamide Color light grey Protection class IP20 Width x length x height 22...

Page 14: ...their dimensions The loss of material must not be more than 1mm The transmission of the devices remains reliable and stable over a long period neither regular adjustments nor maintenances are require...