Mutec FS750E Operating Manual Download Page 10

 

Operating Manual 

MSBA00049

 

Date:  

21.03.2019 

Rev.:  

05 

Page  

10 of 14

 

Operating Manual FS750E 

 

 

 

Mütec Instruments GmbH

 

Tel.: +49 (0) 4185-80 83-0 

E-Mail

[email protected]

 

Bei den Kämpen 26

 

Fax: +49 (0) 4185-80 83-80 

Web:    

www.muetec.de

 

D-21220 Seevetal-Ramelsloh 

7

 

Electrical Connection 

7.1  Connecting the Sensor 

The dust monitor and the DIN-rail transmitter are electrically connected via the 4-wire 
connection  cable.  The  sensor  is  supplied  with  a  pre-assembled  cable

 

(length  3,0 m, 

Ø 4.4 mm,  4 x 0.14 mm²,  insulation:  PVC  or  special  halogen-free  compound)

.

  The  4 

wires of the connection cable are  depicted in figure  5 a). Connect the shield with the 
ground rail (DIN rail) 
 

7.2  Connecting the Transmitter 

The terminal assignment of the transmitter is shown in figure 5 b). It has to be supplied 
with 24V DC. For the analog 4-20mA output, use terminal pin T2 and the shared ground 
on  pin  T4.  Shielded  connection  cables  should  be  used.  Connect  the  shield  with  the 
ground rail (DIN rail). As an alternative, unshielded connection cables can be used, if 
the cable length does not  exceed 3m and the transmitter  is mounted within a  control 
cabinet.  
 

  

a)  4-wire connection cable of the  

 cable screen 

 

b) Power supply and analog output

 

Figure 5: Terminal assignment

 

 

8

 

Commissioning, Calibration and Operation 

8.1  Commissioning 

After  connecting  the  transmitter  to  the  24V  power  supply,  it  starts  the  power  on 
procedure for a few seconds. During this time, the sensor LED flashes blue. The power 
on  procedure  is sinalized  with  3mA  at  the  analog  output.  Subsequently  the  device  is 
ready to use and the measurement value of particle load is output in the 4-20mA range. 

8.2  Calibration 

The  FS750E  is  pre-calibrated  by  the  manufacturer.  The  entire  measuring  range  is 
mapped to the output range 4-20mA. There are two adjustment options for an individual 
customization of the analog output range. 
 
 

Summary of Contents for FS750E

Page 1: ...14 Operating Manual FS750E M tec Instruments GmbH Tel 49 0 4185 80 83 0 E Mail muetec muetec de Bei den K mpen 26 Fax 49 0 4185 80 83 80 Web www muetec de D 21220 Seevetal Ramelsloh Dust monitoring w...

Page 2: ...Instruments GmbH 2019 All rights reserved This document is copyright protected It supports the user in making reliable and efficient use of the unit Transmission and duplication of this document as we...

Page 3: ...troduction 6 4 System Design 7 5 General information on construction and operation 7 6 Mounting Instructions 8 6 1 Selection of the mounting position 8 6 2 Sensor Mounting 8 6 3 Transmitter Mounting 9...

Page 4: ...sical injury may occur if the appropriate precautionary measures are not taken CAUTION without a triangular warning sign means that material damage may occur if the appropriate precautionary measures...

Page 5: ...extended nor limited by the information contained in the manual The content reflects the technical state of the art regarding printing It is subject to technical modifications in the course of furthe...

Page 6: ...and the opposite wall The measurement system is based on the triboelectric effect Particles collide permanently with each other or with other materials e g the wall Because of this process the particl...

Page 7: ...General information on construction and operation Safety instructions If the device can no longer be operated safely it must be put out of operation and secured to prevent unintentional operation The...

Page 8: ...urement window is performed with an 18 mm drill bit Therefor the previously welded sleeve serves as a drilling template After drilling the borehole on the inner pipe wall needs to be trimmed as much a...

Page 9: ...tter Mounting Mount the transmitter on a 35 mm DIN rail according to EN 60715 Install the module in a suitable housing to meet the requirements for the protection class The DIN rail transmitter should...

Page 10: ...pin T2 and the shared ground on pin T4 Shielded connection cables should be used Connect the shield with the ground rail DIN rail As an alternative unshielded connection cables can be used if the cabl...

Page 11: ...iometer maps the lower measuring range to a current output of 4mA By adjusting the potentiometer to the lower or upper end the current output is increased or decreased by up to 4mA respectively If the...

Page 12: ...g material Aluminum Material sensor rod V2A V4A option Isolator PPS Protection class IP65 Weight 700g Tightening torque mounting 40Nm Storage temperature 20 C to 70 C not condensing Operating temperat...

Page 13: ...supply DC voltage 24 VDC 20 to 30 Power consumption max 2 W Power LED green good condition of power supply Housing Material Polyamide Color light grey Protection class IP20 Width x length x height 22...

Page 14: ...their dimensions The loss of material must not be more than 1mm The transmission of the devices remains reliable and stable over a long period neither regular adjustments nor maintenances are require...

Reviews: