Mutec FS750E Operating Manual Download Page 2

 

Operating Manual 

MSBA00049

 

Date:  

21.03.2019 

Rev.:  

05 

Page  

2 of 14

 

Operating Manual FS750E 

 

05 

21.03.2019 

Update of cable screen, sensor rod diameter and material 

J. Scholtyssek 

C. Kutschker 

A. Wist 

04 

09.10.2018 

Update of cable, sensor rod and earthing connection 

C. Kutschker 

J. Scholtyssek 

A. Wist 

03 

15.08.2018 

Update of product picture 

C. Kutschker 

J. Scholtyssek 

A. Wist 

02 

29.03.2018 

Update of dimension drawing 

J. Scholtyssek 

C. Kutschker 

A.Wist 

01 

19.12.2017  First Edition 

C. Kutschker 

J. Scholtyssek 

A. Wist 

REV 

DATE 

DESCRIPTION 

PRPD 

CHKD 

APPR 

 

Operating Manual for FS750E 

                             

 

 

 
 
No.: 

MSBA00049-50 

Issue date: 

03/2019 

 
 
Manufacturer: 

 

Mütec Instruments GmbH 
Bei den Kämpen 26 
21220  Seevetal 
Deutschland 
 
 
Tel.:  +49 (0) 4185 8083-0 
Fax:  +49 (0) 4185 8083-80 
 

 

E-Mail:  

[email protected] 

 

Internet: 

www.muetec.de 

 

 

Copyright © Mütec Instruments GmbH 2019 

All rights reserved 

 

This document is copyright protected. It supports the user in making reliable and efficient use 
of the unit. Transmission and duplication of this document as well as utilization and disclosure 
of  its  content  are  prohibited  unless  expressly  permitted.  Any  breach  or  infringement  shall 
result in liability for damages. The software described in this document is licensed and may 
only be used and copied in accordance with the terms of the license. 
All rights reserved. 
 

Disclaimer

 

We  have  checked  the  content  of  the  printed  document  for  compliance  with  the  described 
hardware and software. Nevertheless, deviations cannot be excluded and consequently we 
cannot assume any guarantee for complete accordance. The data in this printed document 
are checked regularly. Corrections and additions are made in the following version in each 
case. We would be grateful for any suggestions for improvement. 
  

© Mütec Instruments GmbH 

Subject to technical modifications

 

Summary of Contents for FS750E

Page 1: ...14 Operating Manual FS750E M tec Instruments GmbH Tel 49 0 4185 80 83 0 E Mail muetec muetec de Bei den K mpen 26 Fax 49 0 4185 80 83 80 Web www muetec de D 21220 Seevetal Ramelsloh Dust monitoring w...

Page 2: ...Instruments GmbH 2019 All rights reserved This document is copyright protected It supports the user in making reliable and efficient use of the unit Transmission and duplication of this document as we...

Page 3: ...troduction 6 4 System Design 7 5 General information on construction and operation 7 6 Mounting Instructions 8 6 1 Selection of the mounting position 8 6 2 Sensor Mounting 8 6 3 Transmitter Mounting 9...

Page 4: ...sical injury may occur if the appropriate precautionary measures are not taken CAUTION without a triangular warning sign means that material damage may occur if the appropriate precautionary measures...

Page 5: ...extended nor limited by the information contained in the manual The content reflects the technical state of the art regarding printing It is subject to technical modifications in the course of furthe...

Page 6: ...and the opposite wall The measurement system is based on the triboelectric effect Particles collide permanently with each other or with other materials e g the wall Because of this process the particl...

Page 7: ...General information on construction and operation Safety instructions If the device can no longer be operated safely it must be put out of operation and secured to prevent unintentional operation The...

Page 8: ...urement window is performed with an 18 mm drill bit Therefor the previously welded sleeve serves as a drilling template After drilling the borehole on the inner pipe wall needs to be trimmed as much a...

Page 9: ...tter Mounting Mount the transmitter on a 35 mm DIN rail according to EN 60715 Install the module in a suitable housing to meet the requirements for the protection class The DIN rail transmitter should...

Page 10: ...pin T2 and the shared ground on pin T4 Shielded connection cables should be used Connect the shield with the ground rail DIN rail As an alternative unshielded connection cables can be used if the cabl...

Page 11: ...iometer maps the lower measuring range to a current output of 4mA By adjusting the potentiometer to the lower or upper end the current output is increased or decreased by up to 4mA respectively If the...

Page 12: ...g material Aluminum Material sensor rod V2A V4A option Isolator PPS Protection class IP65 Weight 700g Tightening torque mounting 40Nm Storage temperature 20 C to 70 C not condensing Operating temperat...

Page 13: ...supply DC voltage 24 VDC 20 to 30 Power consumption max 2 W Power LED green good condition of power supply Housing Material Polyamide Color light grey Protection class IP20 Width x length x height 22...

Page 14: ...their dimensions The loss of material must not be more than 1mm The transmission of the devices remains reliable and stable over a long period neither regular adjustments nor maintenances are require...