Introduction of Instrument
Main features
◆
2.5Msps high-speed sampling, 1MHz analog bandwidth(Only for oscilloscopes with ACV), 4000 count digital
multimeter.
◆
One-click visual wave, there are three waveform scanning modes: automatic/conventional/single.
◆
Save function for data and waveform in the measurement; a total of 100 sets of data and 10 waveform can be
saved.
◆
When measuring waveforms, you can set parameters independently, such as: time base, amplitude, waveform
scanning mode, etc.
◆
REL, effectively eliminate the lead resistance, distributed capacitance and interference signal.
◆
Multimeter functions include DC/AC voltage/current, resistance, capacitance, frequency, duty cycle,Diode
continuity test.
◆
Automatic/manual switching for measuring range and display of measurement data and historic data on the same
screen.
◆
Overload protection 500mA/10A double protective tube, dual protection of the instrument.
◆
Automatic shutdown in case of no operations for 15 minutes: bright backlight and clear display.
◆
Adopt 2.4 inch color screen display, the display effect is clear.
◆
Higher reliability: no adjustment of potentiometer is required for panel calibration and internal storage calibration.