OPERATION MANUAL

DIGITAL 

MULTIMETER

KM 6030

Summary of Contents for KM 6030

Page 1: ...LE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANYCAUSE WHATSOEVER All transaction are subject to Mumbai Jurisdiction G 17 Bharat Industrial Estate T J Road Sewree W Mumbai 400 015 INDIA Sales Direct 022 24156638 Tel 022 24124540 24181649 Fax 022 24149659 Email kusam_meco vsnl net sales kusam meco co in Website www kusamelectrical com ...

Page 2: ...are measuring current in industrial environment you can easily exceed those ratings The best way to avoid damage is to use a clamp meter or to connect a clamp attachment to your DMM To prevent excess current from flowing through your meter always disconnect the test leads from the circuit under test whenever you change DMM functions Set your meter to the correct function say current and its highes...

Page 3: ...r even death to the user Caution Identifies conditions and actions that could cause damage or Malfunction in the instrument Unpacking Inspection Open the package case and take out the Multimeter Check the following items carefully to see any missing or damaged part 1 Item Description Qty 1 English Operating Manual 1 piece 2 Test Lead 1 pair 3 Temperature Probe 1 piece In the event you find any par...

Page 4: ...Operators Manual Battery Carrying Case Protective Holster Temp Probe F to 104 F 3 ELECTRICAL SPECIFICATION AC VOLTAGE DC VOLTAGE Accuracy 1 0 rdg 5 dgts 1 2 rdg 5 dgts Resolution 1 mV 10 mV 100 mV 1 V Range 2 V 20 V 200 V 750 V AC CURRENT Accuracy 2 0 rdg 5 dgts 1 2 rdg 5dgts 3 0 rdg 10dgts Resolution 1 mA 100 mA 10 mA 10 mA Range 2 mA 200 mA 20 mA 20 A 4 200 mV 2 V 20 V 200 V 1000 V 0 5 rdg 3dgts...

Page 5: ... 400Hz 40mVrms Overload Protection Maximum 36V DC or AC RMS Overload Protection 0 2A 250V Fuse No fuse on 20A range Max Input Current 20A above 10A for 15 sec maximum Measuring Voltage Drop Full range is 200mV DIODE AND CONTINUITY MEASUREMENT Accuracy Resolution Range TEMPERATURE Accuracy 2 0 rdg 5dgts Resolution 1 Hz Range 2 KHz FREQUENCY Range Description hFE TRANSISTOR hFE PARAMETER MEASUREMENT...

Page 6: ...ad fuses To avoid electric shock or damages do not apply more than 1000V between the COM terminal and earth ground Use caution when working with voltages above 60V DC or 30Vrms AC These voltages pose shock hazard Replace the battery as soon as the battery indicator appears With a low battery the Meter might produce false readings that can lead to electric shock and personal injury Turn off the Met...

Page 7: ... Common Input jack 6 ON OFF Switch 7 Capacitance jack 8 Transistor jack 9 Input jack for General Measurement 10 ON OFF Backlight 9 Figure 1 COM VWHz 20A mA NPN B B E E E PNP E C C 20A 10SEC MAX UNFUSED 200mA MAX FUSED 1000V DC 750V AC MAX 1 3 6 4 2 5 7 8 1999 AUTO POWER OFF KM 6030 10 9 Display Symbols see figure 2 H 9 9 9 1 10 Figure 2 ...

Page 8: ... otherwise false readings may be provided n Pay extra attention to the symbol which is located besides the input terminals of the Meter before carrying out measurement A DC voltage measurement see figure 3 Warning To avoid harms to you or damages to the Meter from electric shock please do not attempt to measure voltages higher than 1000VDC or 750V rms although readings may be obtained The DC Volta...

Page 9: ...cted range is overloaded it is required to select a higher range in order to obtain a correct reading n When AC Voltage measurement has been completed disconnect the connection between the testing leads and the circuit under test 14 Caution n If the value of voltage to be measured is unknown use the maximum measurement position 1000V and reduce the range step by step until a satisfactory reading i...

Page 10: ...Measurement see figure 6 16 figure 6 Supply Load COM VWHz 20A mA NPN B B E E E PNP E C C 20A 10SEC MAX UNFUSED 200mA MAX FUSED 1000V DC 750V AC MAX KM 6030 C AC Current Measurement see figure 5 Warning Never attempt an in circuit current measurement where the open circuit voltage between terminals and ground is greater than 60V DC or 30V rms If the fuse burns out during measurement the Meter may b...

Page 11: ...easurement where the open circuit voltage between terminals and ground is greater than 60V DC or 30V rms If the fuse burns out during measurement the Meter may be damaged or the operator himself may be hurt Use proper terminals function and range for the measurement When the testing leads are connected to the current terminals do not parallel them across any circuit The DC current measurement has ...

Page 12: ... between the testing leads and the circuit under test Caution 1 Never connect high voltage to the input sockets with the switch in Resistance range 2 Using Resistance measurement function in a Live circuit will produce false results and may damage the instrument In many cases the suspect component must be disconnected from the circuit to obtain an accurate reading 19 F Capacitance Measurement see ...

Page 13: ...ove 250 C please request for higher temp measurement probe 21 COM VWHz 20A mA NPN B B E E E PNP E C C 20A 10SEC MAX UNFUSED 200mA MAX FUSED 1000V DC 750V AC MAX figure 9 K Type Thermocouple KM 6030 3 Insert the plug with the positive polarity in the positive socket and the negative polarity in the negative socket 4 Set the measurement end of the thermocouple on the temperature measurement point Th...

Page 14: ...op value 24 Figure 11 COM VWHz 20A mA NPN B B E E E PNP E C C 200mA MAX FUSED 1000V DC 750V AC MAX Red Black KM 6030 20A 10SEC MAX UNFUSED The frequency measurement range is 2kHz To measure frequency connect the Meter as follows 1 Insert the red test lead into the VW terminal and the black test lead into the COM Terminal 2 Set the rotary switch in the 2kHz range 3 Connect the test leads across wit...

Page 15: ...onnection between the testing Leads and the circuit under test Testing for Continuity To test for continuity connect the Meter as below 1 Insert the red test lead into VW terminal and the black test lead into the COM terminal 2 Set the rotary switch to position 3 Connect the test leads across with the object being measured The buzzer sounds if the resistance of a circuit under test is less than 50...

Page 16: ... within the warranty period the same will be rectified by us free of charges provided the to and fro freight charges are borne by you This warranty extends only to the original buyer or end user customer of a KUSAM MECO authorized dealer This warranty does not apply for damaged Ic s fuses disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused...