General Precautions

Before using it, read all instructions and markings:
(1) inverter  (2) battery  (3) user manual

CAUTION:

To reduce risk of injury, charge only lead-acid rechargeable batteries. If customer use flooded batteries, batteries 

1. 

    must be maintained regularly. Other battery types may cause damage and injury.

Do not expose it to rain, snow or any type liquids. Inverters are designed for indoor use.

2. 
3.

 Do not disassemble it. Take it to qualified service center when service or repair is needed.

4. 

To prevent the risk of electric shock, disconnect all wiring before attempting any maintenance or cleaning. Only 

    turning off the unit will not reduce the risk.

WARNING: 

1. 

Provide ventilation from the battery compartment to outdoors. The battery enclosure should be designed to 

    prevent accumulation and concentration of hydrogen gas at the top of the compartment.

2. 

NEVER charge a frozen battery and connect such 12V/24V/48V batteries to inverter.

3. 

Input/output AC wiring mustn’t be less than 12AWG and not rated for 75 °C or higher. Battery cable mustn’t be 

    rated for 75°C or higher and should be no less than 4AWG /6AWG gauge.

4. 

Pay special attention when working with metal tools around batteries. Batteries short-circuiting could cause an 

    explosion.

5. 

Read the battery installation and maintenance instructions carefully before operating.

Personnel Precautions

1.

 

Better to prepare plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.

2.

 

Avoid touching eyes while working near batteries.

3.

 

NEVER smoke or allow a spark or flame near batteries.

4.

 

Remove personal metal items such as rings, bracelets, necklaces, and watches when working with batteries. 

     Batteries may provide heavy short-circuit current, which would be enough to make metal melt and causes severe 
    burn.
5.

 

If a remote or automatic generator start system is used, disable the automatic starting circuit or disconnect the 

    generator to prevent accident during servicing

This manual contains important instructions for all Inverter/Charger models that shall be 
followed during installation and maintenance of the inverter.

The following cases are not within the scope of warranty
1. Out of warranty.
2. Series number was changed or lost.
3. Battery capacity was declined or external damaged.
4. Inverter was damaged caused of transport shift, remissness, ect external factor
5. Inverter was damaged caused of irresistible natural disasters.
6. Not in accordance with the electrical power supply conditions or operate environment 
    caused damage.

WARNING!

-1-

Summary of Contents for EP33-1012TLV

Page 1: ...PC TV Air conditioning Fridge Washing machine Appliances INVERTER CHARGER 1012 1024 1512 1524 2012 2024 3024 3048 4024 4048 5048 6048...

Page 2: ...e Unit 4 Operation 8 Operation key instructions 8 Setting key instructions 8 LCD display 10 Operating mode description 11 AGS function 11 AGS function information 11 Dry contact operating voltage 12 B...

Page 3: ...tal tools around batteries Batteries short circuiting could cause an explosion 5 Read the battery installation and maintenance instructions carefully before operating Personnel Precautions 1 Better to...

Page 4: ...multi function display Overload and short circuit protection Set charging voltage charging current Battery low voltage shutdown point can be set to 10 10 5 11V Power save mode Set utility priority Bat...

Page 5: ...N AC Side Panel 1 AC OUTPUT HOT1 N 120VAC 110 VAC 115VAC 2 AC OUTPUT HOT2 N 120VAC 110 VAC 115VAC 3 AC OUTPUT HOT1 HOT2 240VAC 220 VAC 230VAC 4 AC INPUT HOT1 HOT2 240VAC 220 VAC 230VAC 5 15AMAX JFCI...

Page 6: ...Mounting the Unit Consider the following points before selecting where to install Do not mount the inverter on flammable construction materials Mount on a solid surface Install this inverter at eye le...

Page 7: ...enough or connect several combined thin cables together to be same strong Battery bank should be kept close to inverter The shorter and thicker cables the better the system performance Please follow b...

Page 8: ...ent of AC input Suggestion AC breaker 50A for 1KW 3KW 80A for 4KW 6KW CAUTION Please don t connect the output wring to Grid terminal or connect the grid wring to the Load terminal WARNING All wiring m...

Page 9: ...re required at least 2 3 minutes to restart because it s required to have enough time to balance refrigerant gas inside of circuits If a power shortage occurs and recovers in a short time it will caus...

Page 10: ...ormally set To ensure that the parameters can be successfully saved so every time after setting the parameters need restart the machine Setting key instructions MENU Function key Function description...

Page 11: ...d current default Range of adjustment 13 8 14 5V 14 1V default 17 Floating charging setting 13 5V default 10 5V default 18 Range of adjustment 13 5 13 7V 11 5V default 13 5V default 21 LCD ON LCD OFF...

Page 12: ...n switch on The Battery voltage and rated power shall be displayed on the LCD screen when switch on As this shown in Screen 3024 Default Page Output Voltage and Output Frequency Input Voltage and Inpu...

Page 13: ...function AGS function information The AGS function is that the inverter will start the generator automatically via the dry contact when the battery is low voltage Note The generator must have dry con...

Page 14: ...based on drops of boost voltage and float voltage Using an optional battery temperature cable to connect the inverter and battery Communication Upper Computer Monitoring directions Monitoring software...

Page 15: ...er Monitor exe and install Open the PowerMonitor turn on the machine Desktop shortcut Icon 13 Solar Power Monitor exe Advanced Installer SolarPowerMonitor has been successfully installed SolarPowerMon...

Page 16: ...or a moment Power Monitor will work normally Monitor software function operation Specific function Operations of the monitoring software please refering to the HELP docs after the connection is succes...

Page 17: ...0V F 65HZ AC 265V F 65HZ AC 265V F 70HZ AC 270V F 70HZ AC 270V F 45HZ AC 150V F 45HZ AC 190V F 40HZ AC 140V F 40HZ AC 180V narrow wide Charge Mode Specifications Max charge current 5A model 1K 1 5K 2K...

Page 18: ...the charger will run at full current in CC mode until the charger reaches the boost voltage Boost CV Stage the charger will keep the boost voltage in Boost CV mode until the charge current less 6A con...

Page 19: ...Temperature of machine is too high Power off and waiting for minute Fault code 02 Fault code 03 Battery voltage is too high Check the battery specifications Fault code 04 Battery voltage is too low C...

Page 20: ...420 00341 02 INVERTER CHARGER...