-12-
Dry contact operating voltage
Set Low Shutdown Voltage
Operation Voltage
Restoring Voltage
10V/20V/40V
DC<10.5V/21V/42V
DC>13.5V/27V/54V
10.5V/21V/42V
DC<11V/22V/44V
DC>13.5V/27V/54V
11V/22V/44V
DC<11.5V/23V/46V
DC>13.5V/27V/54V
BTS function
BTS function description:
The inverter collects the battery temperature through the BTS port, based on 25°Cwith each rise of 1°C , the
·
charging voltage drops by 18mV/1 at the set charging voltage (up to 60°C).
BTS down charge voltage is based on drops of boost voltage and float voltage.
Using an optional battery temperature cable to connect the inverter and battery.
·
Communication
Upper Computer Monitoring directions:
Monitoring software: This software supports the communication function for various models of our company.
The software will
the COM Port and inverter model automatically.
searching
That is when the dry contact is engaged at DC<set low shutdown point + 0.5V (battery low voltage warning point),
at DC>13.5V. (12V model)
Bts wire
US
B
US
B
Usb wire
The operation steps are as follows:
Connect the Inverter and Computer.
connect the inverter with a communication cable to the computer with usb communication port.
Summary of Contents for EP33-1012TLV